Please complete this information and retain
this manual for the life of the equipment:
Model #: __________________________
Serial #: __________________________
Date Purchased: ___________________
Model X536D Model X560DD
WARNING
This appliance shall be installed in conformity with the current regulations and used only in a well ventilated
location. Consult the instructions before installing and using the appliance.
Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death.
Read installation, operation, and maintenance instructions thoroughly before installing or servicing this equipment.
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526 USA • www.southbendnc.com
OWNER’S MANUAL 1188716(02/07)
$21.00
500SERIES RESTAURANT RANGES
MANUAL SECTION RR
SAFETY PRECAUTIONS 500SERIES RESTAURANT RANGES
SAFETY PRECAUTIONS
Before installing and operating this equipment, be sure everyone involved in its operation is fully trained and aware of
precautions. Accidents and problems can be caused by failure to follow fundamental rules and precautions.
The following symbols, found throughout this manual, alert you to potentially dangerous conditions to the operator,
service personnel, or to the equipment.
DANGER
WARNING
CAUTION
NOTICE
This symbol warns of immediate hazards that will result in severe injury or death.
This symbol refers to a potential hazard or unsafe practice that could result in injury or
death.
This symbol refers to a potential hazard or unsafe practice that could result in injury,
product damage, or property damage.
This symbol refers to information that needs special attention or must be fully understood,
even though not dangerous.
WARNING
FIRE HAZARD
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of cookin g appliances.
Keep area around cooking appliances free and clear of combustibles.
Purchaser of equipment must post in a prominent location detailed instructions to be followed in the event the
operator smells gas. Obtain the instructions from the local gas supplier.
WARNING
BURN HAZARD
Contact with hot surfaces will cause severe burns. Always use caution when operating cooking appliances.
WARNING
EXPLOSION AND ASPHYXIATION HAZARD
In the event a gas odor is detected, shut down equipment at the main gas shut-off valve and immediately call
the emergency phone number of your gas supplier.
Improper ventilation can result in headaches, drowsiness, nausea, and could result in death. Do not obstruct the
flow of combustion and ventilation air to and from cooking appliances.
WARNING
ELECTRIC SHOCK HAZARD
For appliances that use electric power, disconnect the power to the appliance before cleaning. Do not remove
panels that require tools to remove.
NOTICE
This appliance is intended for commercial use, and is only for professional use. It shall be used by trained,
qualified people.
Warranty will be void if service work is performed by other than a qualified technician, or if other than genuine
Southbend replacement parts are installed.
Give this Owner’s Manual and important papers to the proper authority to retain for future reference.
Congratulations! You have purchased one of the finest pieces of heavy-duty commercial cooking equipment on the
market.
You will find that your new equipment, like all Southbend equipment, has been designed and manufactured to meet
the toughest standards in the industry. Each piece of Southbend equipment is carefully engineered and designs are
verified through laboratory tests and field installations. With proper care and field maintenance, you will experience
years of reliable, trouble-free operation. For best results, read this manual carefully.
RETAIN THIS MANUAL FOR FUTURE REFERENCE.
This manual is divided into six sections:
The serial plate is located on the inside surface of the kick panel (see Figure 1 below).
Read these instructions carefully before attempting installation. Installation and initial startup should be performed by
a qualified installer. Unless the installation instructions for this product are followed by a qualified service technician (a
person experienced in and knowledgeable with the installation of commercial gas and/or electric cooking equipment)
then the terms and conditions on the Manufacturer’s Limited Warranty will be rendered void and no warranty of any
kind shall apply.
In the event you have questions concerning the installation, use, care, or service of the product, write to:
Southbend
1100 Old Honeycutt Road
Fuquay-Varina, North Carolina 27526 USA
www.southbendnc.com
Figure 1
Location of Serial Plate
Serial Plate is Located on
Inside Surface of Kick Panel
OWNER’S MANUAL 1188716(02/07) PAGE 3 OF 44
SPECIFICATIONS 500SERIES RESTAURANT RANGES
SPECIFICATIONS
NOTICE
Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association,
Inc., states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to
installation requirements for equipment. Therefore, installations should comply with all local codes.
Southbend reserves the right to change specifications and product design without notice. Such revisions do not
entitle the buyer to corresponding changes, additions, or replacements for previously purchased equipment.
Southbend appliances are intended for commercial use only, not for household use.
The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGAB149.2, as applicable, including:
1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa).
2. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45
kPa).
CLEARANCES
WARNING
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
There must be adequate clearance between ranges and combustible construction. Clearance must also be
provided for servicing and for operation.
Minimum Clearances:
Standard Oven Convection Oven Double Oven Base
Sides 10 inches 10 inches 10 inches
Back 10 inches 10 inches 10 inches
Floor zero zero zero
Ranges are suitable for installation on combustible floors.
Adequate clearance must be provided in the aisle and at the side and rear to allow the door to open sufficiently to
permit the removal of the racks and for serviceability.
On ranges with a convection-type oven, a minimum of 2 inches clearance must be allo wed behind the motor and
the rear non-combustible enclosure. Care must be taken to provide adequate air circulation to prevent the motor
from overheating. No additional clearance from the sides and back is required for service as the ranges are
serviceable from the front.
DIMENSIONS
The exterior dimensions of the restaurant range are shown in Figure 2 on the next page.
PAGE 4 OF 44 OWNER’S MANUAL 1188716(02/07)
500SERIES RESTAURANT RANGES SPECIFICATIONS
Figure 2
Dimensions
Gas Connection
O
Electrical Connection
R
Gas Connection
O
Electric al Connections
RR
I
J
K
E
L
M
SideView of Ranges WITH Convection OvenSide View of Ranges WITHOUT Convect ion Oven
Model Number
536A
536D
560AA
560AD
560DD
See table on next page for dimensions O, P, Q, and R.
A B C D E F G H I J K
36.5"
(927)
36.5"
(927)
60.75"
(1543)
60.75"
(1543)
45.25"
(1149)
36"
(914)
45.25"
(1149)
36"
(914)
10"
(254)
10"
(254)
A
I
J
K
B
DD
C
Electrical
Connection
Q
L
NN
M
A
E
Exterior Dimensions in Inches and (Millimeters)
31.25"
(794)
31.25"
-
(794)
31.25"
(794)
31.25"
-
(794)
33"
(838)
33"
(838)
33"
(838)
33"
(838)
11"
(279)
11"
(279)
11"
(279)
11"
(279)
2.75"
(70)
2.75"
(70)
2.75"
(70)
2.75"
(70)
59.5"
(1511)
59.5"
(1511)
59.5"
(1511)
59.5"
(1511)
22.5"
(587)
22.5"
(587)
22.5"
(587)
22.5"
(587)
31.0"
(787)
31.0"
(787)
31.0"
(787)
31.0"
(787)
B
6"
(152)
6"
(152)
6"
(152)
6"
(152)
FFG
G
Gas Connection
Cook Top
Height
L
37.0"
(914)
37.0"
(914)
37.0"
(914)
37.0"
(914)
P
Door
Depth
M
15.5"
(394)
15.5"
(394)
15.5"
(394)
15.5"
(394)
Oven
Bottom
N
13"
(318)
13"
(318)
13"
(318)
13"
(318)
OWNER’S MANUAL 1188716(02/07) PAGE 5 OF 44
SPECIFICATIONS 500SERIES RESTAURANT RANGES
INTERIOR DIMENSIONS AND UTILITY DATA
Left (or Only) Oven
Model Number
X536A
X536D
X560AA
X560AD
X560DD
S536A
S536D
S560AA
S560AD
S560DD
* See figure on previous page for location of utility connections.
Interior Dimensions
Width Depth Height Width Depth Height Open Oven
26.125"
(664)
(660)
26.125"
(664)
26.125"
(664)
(660)
26.125"
(664)
(660)
26.125"
(664)
26.125"
(664)
(660)
26"
26"
26"
26"
24"
(610)
26.5"
(673)
24"
(610)
24"
(610)
26.5"
(673)
24"
(610)
26.5"
(673)
24"
(610)
24"
(610)
26.5"
(673)
14.25"
(362)
14"
(356)
14.25"
(362)
14.25"
(362)
14"
(356)
14.25"
(362)
14"
(356)
14.25"
(362)
14.25"
(362)
14"
(356)
Interior Dimensions
- - -
- - -
26.125"
(664)
26"
(660)
26"
(660)
- - -
- - -
26.125"
(664)
26"
(660)
26"
(660)
Right Oven
24"
(610)
26.5"
(673)
26.5"
(673)
24"
(610)
26.5"
(673)
26.5"
(673)
14.25"
(362)
14"
(356)
14"
(356)
14.25"
(362)
14"
(356)
14"
(356)
Burners
(number of and BTU/hour)
6@33,000 Nat
6@24,000 LP
6@33,000 Nat
6@24,000 LP
10@33,000 Nat
10@24,000 LP
10@33,000 Nat
10@24,000 LP
10@33,000 Nat
10@24,000 LP
6@27,000 Nat
6@21,000 LP
6@27,000 Nat
6@21,000 LP
10@27,000 Nat
10@21,000 LP
10@27,000 Nat
10@21,000 LP
10@27,000 Nat
10@21,000 LP
1@32,000 Nat
1@30,000 LP
1@45,000 Nat
1@40,000 LP
2@32,000 Nat
2@30,000 LP
1@32,000 and
1@45,000 Nat
1@30,000 and
1@40,000 LP
2@45,000 Nat
2@40,000 LP
1@32,000 Nat
1@30,000 LP
1@45,000 Nat
1@40,000 LP
2@32,000 Nat
2@30,000 LP
1@32,000 and
1@45,000 Nat
1@30,000 and
1@40,000 LP
2@45,000 Nat
2@40,000 LP
Total BTU/hour
230,000 Nat
174,000 LP
243,000 Nat
184,000 LP
394,000 Nat
300,000 LP
407,000 Nat
310,000 LP
420,000 Nat
320,000 LP
194,000 Nat
156,000 LP
207,000 Nat
166,000 LP
334,000 Nat
270,000 LP
347,000 Nat
280,000 LP
360,000 Nat
290,000 LP
Gas Connection
Location
O* P* Q* R*
3.25"
(82)
3.25"
(82)
3.25"
(82)
3.25"
(82)
3.25"
(82)
3.25"
(82)
3.25"
(82)
3.25"
(82)
3.25"
(82)
3.25"
(82)
30.25"
(768)
30.25"
(768)
30.25"
(768)
30.25"
(768)
30.25"
(768)
30.25"
(768)
30.25"
(768)
30.25"
(768)
30.25"
(768)
30.25"
(768)
Electric Connect.
Location
24"
(610)
24"
(610)
24"
(610)
24"
(610)
24"
(610)
24"
(610)
6"
(152)
- 6"
(152)
6"
(152)
- 6"
(152)
- 6"
(152)
6"
(152)
- -
VENTILATION
WARNING
Improper ventilation can result in personal injury or death. Ventilation which fails to properly remove flue products
can cause headaches, drowsiness, nausea, or could result in death.
All ranges must be installed in such a manner that the flow of combustion and ventilation air are not obstructed.
Provisions for adequate air supply must be provided. Do not obstruct the front of the range at the top by the control
panel, or the bottom just below the oven compartment, as combustion air enters through these areas.
NOTICE
Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be covered by the
warranty.
Be sure to inspect and clean the ventilation system according to the ventilation equipment manufacturer’s
instructions.
Canopies are set over ranges, ovens, etc., for ventilation purposes. It is recommended that a canopy extend 6" past
the appliance and the bottom edge be located 78" above the floor. Filters should be installed at an angle of 45° or
more from the horizontal. This position prevents dripping grease and facilitates collecting the run-off grease in a drip
pan, unusually installed with a filter.
A strong exhaust fan tends to create a vacuum in the room and may interfere with burner performance or may
extinguish pilot flames. Fresh air openings approximately equal to the fan area will relieve such a vacuum.
The exhaust fan should be installed at least 2" above the vent opening at the top of the range.
If the range is connected directly to an outside flue, a CSA design-certified down draft diverter must be installed at the
flue outlet of the oven and connected to the flue.
PAGE 6 OF 44 OWNER’S MANUAL 1188716(02/07)
500SERIES RESTAURANT RANGES SPECIFICATIONS
In case of unsatisfactory performance on any appliance, check the appliance with the exhaust fan in the OFF position.
Do this only long enough to check equipment performance. Then turn hood back on and let it run to remove any
exhaust that may have accumulated during the test.
GAS SUPPLY
A 3/4" female NPT gas connection is located on the rear of the range (see Figure 2).
The serial plate is located on the right side of the range (See
range is equipped to burn. All Southbend equipment is adjusted at the factory. Check type of gas on serial plate.
These models are design-certified for operation on natural or propane gases. For natural gas, the regulator is set to 4"
W.C. (0.99 kPa). For propane gas, it is set to 10" W.C. (2.48 kPa).
If applicable, the vent line from the gas appliance pressure regulator shall be installed to the outdoors in accordance
with local codes, or in the absence of local codes, with the applicable national codes.
This appliance should be connected ONLY to the type of gas for which it is equipped.
An adequate gas supply is imperative. Undersized or low pressure lines will restrict the volume of gas required for
satisfactory performance. Fluctuations of more than 25% on natural gas or 10% on propane gas will create problems
and affect burner operating characteristics. A 1/8" pressure tap is located on the manifold to measure the manifold
pressure.
An adequate gas supply line to the range should be no smaller than the inside diameter of the pipe from the range to
which it is connected.
Purge the supply line to clean out dust, dirt, or other foreign matter before connecting the line to the range.
All pipe joints and connections must be tested thoroughly for gas leaks. Use only soapy water for testing on all gases.
NEVER use an open flame to check for gas leaks. All connections must be checked for leaks after the range has
been put into operation. Test pressure should not exceed 14" W.C. (3.47 kPa).
Figure 1). The serial plate indicates the type of gas the
ELECTRICAL REQUIREMENTS
Ranges with a convection oven require connection to a supply of electricity. The appliance, when installed, must be
electrically grounded in accordance with local codes, or in the absence of local codes, with the applicable national
codes. An electrical diagram is located on the rear of the range, near the motor.
Usually the range is furnished with one or two power cords (one for each oven), each with a standard 115V, 60Hz,
single-phase prong plug. Total maximum power for 115V units is 4.8 amperes.
The range can be ordered to operate on 208V 60Hz 1-phase or 3-phase current, in which case the electric power
supply must be wired to one or two junction boxes (one for each oven), each with a terminal block on the rear of the
range. Total maximum power for 208V units is 2.6 amperes.
OWNER’S MANUAL 1188716(02/07) PAGE 7 OF 44
OPERATION500SERIES RESTAURANT RANGES
OPERATION
DANGER
EXPLOSION AND ASPHYXIATION HAZARD
In the event a gas odor is detected, shut down equipment at the main gas shut-off valve and immediately call
the emergency phone number of your gas supplier.
Improper ventilation can result in headaches, drowsiness, nausea, and could result in death. Do not obstruct the
flow of combustion and ventilation air to and from cooking appliances.
CAUTION
To eliminate gas build up which could result in an explosion, in the event of main burner ignition failure wait five
minutes before attempting to relight the pilot or burner.
The controls for the burners and oven(s) are located on the valve panel on the front of the range.
If the pilots need to be lit, follow the steps listed in each section below.
LIGHTING AFTER GAS HAS BEEN SHUT OFF
When turning the main gas supply on after the gas supply has been shut off, do the following:
1. Make sure the gas supply valve, located on the front valve panel, is in the OFF position.
2. Make sure all of the control valves are in the OFF position.
3. Turn on the incoming gas supply.
4. Turn the gas supply valve, located on the front valve panel, to the ON position.
5. Light the pilots as described below.
6. Light the oven first and then wait six minutes before lighting top burners to purge all air from the range.
OPERATION OF TOP BURNERS
To operate a top burner, turn the corresponding control knob on the front panel to the desired flame level.
Each top burner has its own pilot. If a top-burner pilot needs to be lighted, do the following:
1. Turn all the top-burner control knobs to the OFF position.
2. On S500 models, turn one of the top-burner control knobs to the pilot position, push the knob inward, and
hold it in place. Depress and hold down the spark switch (the black button between the control valves). A
spark from the ignitor to the pilot can be seen and heard. When the pilot lights, release the spark switch, but
continue holding the knob in for 30 to 45 seconds. When the knob is released, the pilot should remain lit.
On X500 models, depress and hold down the spark switch (the black button between the control valves). A
spark from the ignitor to the pilot can be seen and heard. When the pilot lights, release the spark switch.
3. Repeat step 2 for the all other top-burner pilots that need to be lighted.
OPERATION OF OVEN
To operate an oven, turn the oven-thermostat knob on the front panel to the desired temperature. On convection
ovens, the blower is controlled by an ON-OFF switch.
Each oven has its own pilot. If an oven pilot needs to be lighted, do the following:
1. Turn the oven thermostat to the OFF position.
2. For convection ovens, turn the fan switch to the OFF position.
3. Open the oven door and remove the oven bottom and fire plate to expose pilot and burner.
4. Open the kick panel below the oven door and depress red button on oven safety valve.
5. Light constant pilot (the pilot without a capillary tube holder).
6. Close the kick panel and replace the fire plate and oven bottom.
PAGE 8 OF 44 OWNER’S MANUAL 1188716(02/07)
500SERIES RESTAURANT RANGESOPERATION
SHUTDOWN OF ENTIRE RANGE
To completely shut down the range for an extended period (or prior to disconnecting the gas su pply), do the following:
1. Turn all burner control knobs to OFF.
2. Turn the oven thermostat knob(s) to the lowest temperature.
3. Turn the main gas valve on the valve panel to OFF.
4. Turn-off the gas supply to the oven.
TROUBLESHOOTING BY OPERATOR
The following table lists the possible causes and solutions of problems that may occur during operation.
Problem Possible Causes and Solutions
A top burner will not light. – Check pilot position.
– Check and light the burner’s pilot.
– Check gas supply to range.
Oven will not heat up. – Check and light the oven pilot.
– Check gas supply to range.
Blower of convection oven is not running. – Check that the oven’s blower control switch is in ON position.
– Check electricity supply to range.
Pilot(s) will not remain lit. – Check gas supply to range.
– Check pilot adjustment.
If other appliances connected to the same source of gas or electricity are also not operating correctly, the problem is
likely not within the range.
If the problem only occurs for the range, and if the above solutions to do not solve the problem, call for repair service.
TROUBLESHOOTING CONVECTION-OVEN COOKING PROBLEMS
If… then…
Cakes are dark on the sides and not done in the center… lower oven temperature.
Cake edges are too brown… reduce number of pans or lower oven temperature.
Cakes have light outer color… raise temperature.
Cake settles slightly in the center… bake longer or raise oven temperature slightly. Do not
open doors too often for long periods.
Pies have uneven color… reduce number of pies per rack.
Meats are browned and not done in center… lower oven temperature and roast longer.
Meats are well done and not browned… raise temperature. Limit amount of moisture.
Cakes ripple… overloading pans or batter is too thin.
There is excessive meat shrinkage… lower oven temperature.
Cakes are too coarse… lower oven temperature.
WARNING
THE USE OF ALUMINUM FOIL CAN CAUSE HEAT DISTRIBUTION PROBLEMS IN OVENS. EXTREME
CARE MUST BE USED WHEN PLACING ALUMINUM FOIL IN THE OVEN TO ENSURE THAT IT DOES NOT
BLOCK OR CHANGE THE AIR FLOW. THE USE OF ALUMINUM FOIL MAY VOID THE PRODUCT
WARRANTY IF ITS USE IS ASCERTAINED TO BE A PROBLEM.
OWNER’S MANUAL 1188716(02/07) PAGE 9 OF 44
OPERATION500SERIES RESTAURANT RANGES
COOKING TIPS FOR CONVECTION OVENS
As a guide, set oven temperatures 25 to 50 degrees lower than called for in recipes using conventional (nonconvection) ovens.
FROZEN ENTREE PRODUCTS: Punch holes in lid before heating. Tent lid if product has a tendency to stick, i.e.,
lasagna or macaroni and cheese. Use manufacturer’s convection oven directio ns for time and temperature or reduce
conventional oven temperature 50 degrees for a 6-1/2 size pan load. Some products may cook in 10 to 15 minutes
less time than recommended for convection ovens if prepared from frozen in a 6 pan load.
Time and temperatures will vary depending upon load, mix, size of portion, and other factors. Use the following chart
to develop your own cooking techniques:
Product
Hamburger buns, 3 oz. - 4" 18 375° 2 24
Timing
(minutes)
Temperature
Setting
Number of
Racks Used
Count per
Pan/Rack
Yeast rolls - 1 oz.
10 400° 2 48
Use temperature and time recommended by
manufacturer for convection ovens for a 3 pan load.
Fruit pies, 46 oz. frozen
50 375° 2 4
Use temperature and time from manufacturer’s directions
for convection ovens for a 12 pie load placed on 3 bun
pans.
Egg custard pies, 44 oz. frozen 60 325° 2 4
Dutch apple pies, 46 oz. frozen 50 350° 2 4
Baked potatoes, 8 oz.
60 400° 2 30 (wrapped)
Wash and wrap in potato foil. Place 30 potatoes on 18 x
24 bun pan — 3 pans per load. Bake in 400°F oven for 1
hour.
Pre-blanched potatoes, frozen
16 400° 2 5 lb.
Spread on ungreased bun pans, 3 pans per load. Bake
at 400°F, stirring once, for 15 to 18 minutes.
Fish portions, pre-cooked, breaded, 3 oz.
16 400° 2 32
Use manufacturer’s recommended temperature and time
for convection oven for a 3 pan load.
Shut off the range and allow time for it to cool before cleaning or performing maintenance.
Southbend appliances are sturdily constructed of the best materials and are designed to provide durable service when
treated with ordinary care. To expect the best performance, your equipment must be maintained in good condition and
cleaned daily. Naturally, the periods for this care and cleaning depend on the amount and degree of usag e.
Following daily and periodic maintenance procedures will enhance long life for your equipm ent. Climatic conditions
(such as salt air) may require more thorough and frequent cleaning or the life of the equi pment could be adversely
affected.
Keep exposed, cleanable areas clean at all times.
DAILY CLEANING
1. Turn all controls to OFF and allow time for the range to cool.
2. Remove, empty, and clean drip trays.
3. Wipe clean all cooking surfaces.
CLEANING OVEN INTERIOR
WARNING
FOR YOUR SAFETY, BEFORE CLEANING A CONVECTION OVEN DISCONNECT THE POWER SUPPLY.
WHEN CLEANING THE BLOWER WHEEL, BE SURE THAT THE POWER SWITCH IN THE “OFF” POSITION.
Allow oven to cool. Remove porcelain enameled oven bottom. Clean by rubbing with strong detergent and Brillo pad
or similar scrubber. “Spill-overs” should be cleaned from the bottom as soon as possible to prevent carbonizing and a
“burnt-on” condition. For stubborn accumulations, commercial oven cleaners are recommended.
The porcelain oven door lining can be cleaned in a similar manner.
The side, rear and top lining should be wiped only with a cloth dampened with a mild detergent and water. Avoid using
excessive amounts of water, as this may drip into burner compartment and deteriorate the metal in that area. Do not
use strong commercial cleaners or abrasive pads on the side, rear or top linings, as they may damage the finish or
leave gray residue.
PERIODIC CLEANING AND MAINTENANCE
At least monthly, clean around burner air mixers and orifices if lint has accumulated and visually check proper pilot
operation.
At least twice a year, examine and clean the range hood and venting system.
If range-top spillage should occur, it may be necessary to clean around pilot areas, air mixer, and under burners. Use
a wire brush if necessary.
If any burners become clogged, remove and clean them. Allow interior to drain. Dry thoroughly before replacing.
BLUE BAKED-ENAMEL SURFACES
Wash exterior blue baked-enamel surfaces with a hot, mild detergent or soap solution to clean off all grease deposits.
Dry thoroughly with a dry cloth.
OWNER’S MANUAL 1188716(02/07) PAGE 11 OF 44
CLEANING &MAINTENANCE 500SERIES RESTAURANT RANGES
STAINLESS-STEEL SURFACES
To remove normal dirt, grease and product residue from stainless steel surfaces that operate at LOW temperature,
use ordinary soap and water (with or without detergent) applied with a sponge or cloth. Dry thoroughly with a clean
cloth.
To remove BAKED-ON grease and food splatter, or condensed vapors; apply cleanser to a damp cloth or sponge and
rub cleanser on the metal in the direction of the polishing lines on the metal. Rubbing cleanser, as gently as possible,
in the direction of the polished lines will not mar the finish of the stainless steel. NEVER RUB WITH A CIRCULAR
MOTION. Soil and burnt deposits which do not respond to the above procedure can usually be removed by rubbing
the surface with SCOTCH-BRITE scouring pads or STAINLESS scouring pads. DO NOT USE ORDINARY STEEL
WOOL as any particles left on the surface will rust and further spoil the appearance of the finish. NEVER USE A
WIRE BRUSH, STEEL SCOURING PADS (EXCEPT STAINLESS), SCRAPER, FILE OR OTHER STEEL TOOLS.
Surfaces which are marred collect dirt more rapidly and become more difficult to clean. Marring also increases the
possibility of corrosive attack. Refinishing may then be required.
“Heat tint” is darkened areas that sometimes appear on stainless steel surfaces where the area has been subjected to
excessive heat. These darkened areas are caused by thickening of the protectiv e surfa ce of t he stainless steel and
are not harmful. Heat tint can normally be removed by the foregoing, but tint which does not respond to this procedure
calls for a vigorous scouring in the direction of the polish lines using SCOTCH-BRITE scouring pads or a STAINLESS
scouring pad in combination with a powered cleanser. Heat tint may be lessened by reducing heat to equipment
during slack periods.
BRIGHT-ANNEALED STAINLESS-STEEL SURFACES
To remove normal dirt, grease and product residue from stainless steel surfaces that operate at LOW temperature,
use ordinary soap and water (with or without detergent) applied with a sponge or cloth. Dry thoroughly with a clean
cloth.
Never use any abrasive cleaner, pad, wire brush, scrapper, or file to remove material from the bright-annealed
surfaces.
PAGE 12 OF 44 OWNER’S MANUAL 1188716(02/07)
500SERIES RESTAURANT RANGES INSTALLATION
INSTALLATION
NOTICE
These installation procedures must be followed by qualified personnel or warranty will be void.
Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association,
Inc., states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to
installation requirements for equipment. Therefore, installations should comply with all local codes.
The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGAB149.2, as applicable, including:
1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa).
2. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45
kPa).
NOTICE
EXHAUST FANS AND CANOPIES: It is recommended that the range be installed under a ventilation hood.
Consult local codes for proper installation of hoods. Proper ventilation is the owner’s responsi bility. Any problem
due to improper ventilation will not be covered by warranty.
NOTICE
In the Commonwealth of Massachusetts all gas appliances vented by either mechanical systems or ventilation
hoods shall comply with 248 CMR interlocking requirements.
STEP 1:UNPACKING
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE
All containers should be examined for damage before and during unloading. The freight carrie r has assumed
responsibility for its safe transit and delivery. If damaged equipment is received, either apparent or conceal ed, a
claim must be made with the delivering carrier.
Apparent damage or loss must be noted on the freight bill at the time of delivery. The freight bill must then be
signed by the carrier representative (Driver). If the bill is not signed, the carrier may refuse the claim. The carrier
can supply the necessary forms.
A request for inspection must be made to the carrier within 15 days if there is concealed damage or loss that is not
apparent until after the equipment is uncrated. The carrier should arrange an inspection. Be certain to hold all
contents plus all packing material.
Do the following:
1. Cut the banding straps and remove the corrugated cardboard surrounding the range. If legs were shipped in
the same container, set them aside for installation in later steps of this procedure. Do not remove any tags or
labels attached to the range until the range is installed and working properly.
2. Lift the flue riser off the front of the skid (see
3. Pull the shelf assembly out from under the base and set it aside for installation later in this procedure.
4. Unbolt the shipping hold-down brackets from the skid, then remove the brackets from the range.
5. If the range is to be installed on legs, go to Step 2a.
If the range is to be installed on casters, go to Step 2b.
Figure 3) and set it aside for installation later in this procedure.
OWNER’S MANUAL 1188716(02/07) PAGE 13 OF 44
INSTALLATION 500SERIES RESTAURANT RANGES
Figure 3
Unpacking
Base
Flue Riser
Shelf
Skid
STEP 2A:ATTACH LEGS
A set of four legs is packed with ranges ordered with legs. (For ranges ordered with casters, go to Step 2b .)
A threaded leg pad is fastened to the base frame at each corner. Each leg has a correspondin g mating thread. The
legs can be adjusted to overcome a slightly uneven floor.
1. Raise range sufficiently to allow leg pads and legs to be attached. For safety, “shore up” and support the range
with an adequate blocking arrangement strong enough to support the load.
2. Attach the four leg pads to the bottom of the range using the lock washers and machine screws. The
mounting holes are pre-drilled and threaded.
3. Screw the legs into the holes in the centers of the leg pads.
4. Lower range gently onto a level surface. Never drop or allow the range to fall.
5. Use a level to make sure that the range surface is level. The legs can be screwed in or out to lower or raise
each corner of the range.
6. Go on to Installation Step 3.
Figure 4
Installation of Legs
PAGE 14 OF 44 OWNER’S MANUAL 1188716(02/07)