ElEctric countEr
c
onvEction StEamEr
a
uto Fill, auto Drain
Compartment Pan Capacity
Model
R24-3 6 3 2 1
R24-5 10 5 3 2
Electrically heated steam generator operating at 0 psi (0 kPa)
with eld replaceable elements rated at:
7.5 kW for Model R24-3
15.0 kW for Model R24-5
The steam generator shall be equipped for operation on:
208 VAC, 3 Phase, 50/60 Hz. *
240 VAC, 3 Phase, 50/60 Hz. *
220 VAC, 3 Phase, 50/60 Hz. *
380/220 VAC, 3 Phase, 50/60 Hz 4 wire.
415/240 VAC, 3 Phase, 50/60 Hz 4 wire.
1” 2-1/2” 4” 6”
PanDepth
Job Item#
R24-3 shown on optional stand
SPECIFICATIONS:
Shall be a Southbend model R24-3 (3 pan) or R24-5 (5 pan) counter
convection steamer with electric steam generator, c-CSA-us and NSF
certied. Unit shall be constructed of satin nish 304 stainless steel with
a one piece welded 316 stainless steel cooking chamber with coved
corners. The door shall have a removable inner liner of stainless steel
with full perimeter gasket seal, an outer liner of one-piece all welded
stainless steel, and a positive lock and seal mechanism. The steamer
shall have removable stainless steel pan supports and a stainless steel
drip trough integrally connected to the drain in order to collect condensate
when the door is opened, and adjustable leveling feet.
The control housing shall be constructed of stainless steel with a full
access removable panel. The controls shall include an illuminated three
way power switch (On/Off/De-lime), a pilot ready light, a pilot cook light,
60 minute electric timer with audible alarm at the end of the cooking
cycle. Steam ow to the cooking chamber shall be interrupted when the
door is opened and shall be reactivated when door is closed. Standard
features include a de-liming port located at the rear of the unit for easy
access to allow cleaning of the generator tank, de-lime mode power
setting, automatic blowdown valve, solid state liquid level controls and
split water connections for simple hook up to a water treatment system.
The steamer is constructed so that it may be mounted ush to the
counter top or on 4” (102 mm) legs. The steamer may also be stacked
using a stacking kit.
*SEE REVERSE SIDE OF SPEC SHEET FOR WATER
TREATMENT SYSTEM STATEMENTS*
OPERATION SHALL BE BY:
* UNIT SHALL BE FIELD CONVERTIBLE TO SINGLE PHASE
STANDARD FEATURES:
- Water Treatment System
- 304 stainless steel exterior
- 316 stainless steel cooking chamber with coved corners
- Heavy gauge stainless steel door with full perimeter gasket
- Positive lock and seal mechanism with spring release door
- Illumnated power switch
- Ready indicator light
- Cooking indicator light
- 60 minute electromechanical timer with end of cycle audible
alarm
- Removable stainless steel pan supports
OPTIONS AND ACCESSORIES:
380 VAC, 3 phase, 50/60 Hz.
415 VAC, 3 phase, 50/60 Hz.
480 VAC, 3 phase, 50/60 Hz.
600 VAC, 3 phase, 50/60 Hz.
Increase 7.5 kW to 10 kW (R24-3 only)
Increase 12 kW to 15 kW (R24-5 only)
Correctional package
High sensitivity level controls (R.O. water)
Constant steam feature
120 minute timer
Load compensating timer
4” (102 mm) adjustable legs
Stacking kit for (2) units
Interconnect plumbing for 2 units
28” high single unit stand
34” high single unit stand
18” high double unit stacking stand
23” high double unit stacking stand
Form R24 Rev 5 (March/2015)
www.yatesgd.com www.yatesgraphicdesign.com
Models:
R24-3 R24-5
SERVICE CONNECTIONS
– ELECTRICAL CONNECTION: Rating to be as specied on data plate.
Model Shipping Weight MiniMuM ClearanCe
R24-3 141 lbs. [64 kg]
R24-5 169 lbs. [77 kg]
R24-3
R24-5
SIDES
BACK
0
0
R24-3
R24-5
– COLD WATER: 3/8” (10 mm) O.D. tubing at 25-50 psi (170-345 kPa).
– DRAIN: 2” (51 mm) IPS piped to open oor drain. No solid connection.
– GENERATOR WATER: 3/8” (10 mm) O.D. tubing at 25-50 psi (170-345 kPa).
ELECTRICAL CHARACTERISTICS
amPS/PHaSE
moDEl kW
208v 220v 240v 380v 415v 480 v 600v
1 PH 3 PH 1 PH 3 PH 1 PH 3 PH 3 PH 3 PH 3 PH 3 PH
R24-3
7.5 Standard 36 21 34 20 31 18 12 11 9 8
10 Optional 48 28 46 26 42 24 16 14 12 10
R24-5 15 Standard 72 42 69 39 63 36 23 21 18 15
WATER QUALITY STATEMENT
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a local water
treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Total dissolved solids.......................Less than 60 PPM
Total alkalinity ................................ Less than 20 PPM
Silica ...............................................Less than 13 PPM
Chlorine .........................................Less than 1.5 PPM
pH Factor ......................................7.0 - 8.5
Water which fails to meet these standards should be treated by installation of water conditioner.
SOUTHBEND WATER TREATMENT SYSTEM MUST BE USED, FOR THIS APPLIANCE TO BE COVERED UNDER WARRANTY*
*FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.
Reference www.southbendnc.com for complete warranty details and restrictions.
Form R24 Rev 5 (March/2016)
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526