Please complete this information and retain this
manual for the life of the equipment:
Model #:
Serial #:
Date Purchased:
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury
or death. Read the installation, operating and maintenance instructions thoroughly before installing or
MANUAL 1190950 REV 2 (11/14) ECN - 14-156
$21.00
WARNING
servicing this equipment.
1100 Old Honeycutt Road Fuquay-Varina, North Carolina 27526 USA
www.southbendnc.com
PLATINUM STEAKHOUSE BROILER
MANUAL SECTION BR
SAFETY PRECAUTIONS
STEAKHOUSE BROILER
SAFETY PRECAUTIONS
Before installing and operating this equipment, be sure everyone involved in its operation is fully trained and aware of
precautions. Accidents and problems can be caused by failure to follow fundamental rules and precautions.
The following symbols, found throughout this manual, alert you to potentially dangerous conditions to the operator,
service personnel, or to the equipment.
DANGER
WARNING
CAUTION
NOTICE
This symbol warns of immediate hazards that will result in severe injury or death.
This symbol refers to a potential hazard or unsafe practice that could result in injury or death.
This symbol refers to a potential hazard or unsafe practice that could result in injury, product
damage, or property damage.
This symbol refers to information that needs special attention or must be fully
understood, even though not dangerous.
WARNING
FIRE HAZARD
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
Keep area around cooking appliances free and clear of combustibles.
Purchaser of equipment must post in a prominent location detailed instructions to be followed in the event the
operator smells gas. Obtain the instructions from the local gas supplier.
WARNING
BURN HAZARD
Contact with hot surfaces will cause severe burns. Always use caution when operating cooking appliances.
WARNING
EXPLOSION AND ASPHYXIATION HAZARD
In the event a gas odor is detected, shut down equipment at the main gas shut-off valve and immediately call the
emergency phone number of your gas supplier.
Improper ventilation can result in headaches, drowsiness, nausea, and could result in death. Do not obstruct the ow
of combustion and ventilation air to and from cooking appliances.
WARNING
ELECTRIC SHOCK HAZARD
For appliances that use electric power, disconnect the power to the appliance before cleaning. Do not remove
panels that require tools to remove. Disconnect power before opening kick panel below oven.
NOTICE
This appliance is intended for commercial use, and is only for professional use. It shall be used by trained,
qualied people.
Warranty will be void if service work is performed by other than a qualied technician, or if other than genuine
Southbend replacement parts are installed.
Give this Owner’s Manual and important papers to the proper authority to retain for future reference.
This manual is for the Southbend Radiant Steakhouse Broiler, which may be mounted on a stand, a cabinet, a
refrigeration base, or a countertop. The serial plate is located in the rear right lower corner (see Figure 1 below).
Southbend steakhouse broilers are unique in design. They utilize Southbend’s high performance radiant burners
to provide broiling temperatures of up to 850°F (454°C) on the rack surface. The spent gases are then bafed and
transferred to the top searing griddle providing a uniform temperature of 650°F (343°C). This secondary cooking surface
is perfect for searing meat and locking in juices before broiling, and is provided without additional fuel cost or burners.
The broiler design supplies 100% clean primary air to the burners, ensuring efcient combustion and maintaining
full production capacity and maximum recovery even in the most severe conditions of grease vapors and smoke
atmospheres, which are created during any broiling process.
Read these instructions carefully before attempting installation. Installation and initial startup should be performed by
a qualied installer. Unless the installation instructions for this product are followed by a qualied service technician (a
person experienced in and knowledgeable of the installation of commercial gas and/or electric cooking equipment) then
the terms and conditions on the Manufacturer’s Limited Warranty will be rendered void and no warranty of any kind shall
apply.
In the event you have questions concerning the installation, use, care, or service of the product, contact:
Southbend
1100 Old Honeycutt Road
Fuquay-Varina, North Carolina 27526 USA
Figure 1
Broiler Serial Plate Location
ocation of Serial Plate
(on rear of unit)
OWNER’S MANUAL 1190950 REV 2 (11/14)
PAGE
3
OF 22
SPECIFICATIONS
STEAKHOUSE BROILER
SPECIFICATIONS
NOTICE
Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association, Inc.
states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to installation
requirements for equipment. Therefore, installations should comply with all local codes.
Southbend reserves the right to change specications and product design without notice. Such revisions do not entitle
the buyer to corresponding changes, additions, or replacements for previously purchased equipment.
This product is intended for commercial use only, not for household use.
The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA-B149.2,
as applicable, including:
1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa).
2. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve `
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45
kPa).
CLEARANCES
WARNING
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
There must be adequate clearance between the broiler and adjacent construction due to the heat generated by the
broiler. Clearance must also be provided for servicing, and for combustion air to enter the rear of the broiler.
Due to the heat of the broiler, the minimum clearance from combustible construction on the sides and rear is 8 inches
(203 mm). The minimum clearance from non-combustible construction due to heat is zero inches, however the
minimum side clearance for servicing is 6 inches (152 mm). The minimum rear clearance, both for servicing and for
combustion-air ow, is 6 inches (152 mm).
Adequate clearance must be provided in front of the broiler for operation and cleaning.
The high-temperature ue products from the broiler burners ow out through a ue chamber at the top rear of the
broiler. Installation under a vented hood is recommended.
The minimum clearance from combustible surfaces on the sides and rear is 8 inches (203 mm).
VENTILATION
WARNING
Improper ventilation can result in personal injury or death. Ventilation which fails to properly remove ue products can
cause headaches, drowsiness, nausea, or could result in death.
All units must be installed in such a manner that the ow of combustion and ventilation air is not obstructed. Provisions
for adequate air supply must be provided. Do not obstruct the front of the unit at the bottom where the air lter is
located or below the oven door as combustion air enters at these locations.
PAGE
4
OF 22
OWNER’S MANUAL 1190950 REV 2 (11/14)
STEAKHOUSE BROILER
SPECIFICATIONS
NOTICE
Proper ventilation is the owner’s responsibility. Any problem due to improper ventilation will not be covered by the
warranty.
Be sure to inspect and clean the ventilation system according to the ventilation equipment manufacturer’s instructions.
If a ventilation canopy is used, it is recommended that the canopy extend 152.4 mm (6”), past the appliance and that
the bottom edge be located 1981 mm (6’6”) from the oor. Filters should be installed at an angle of 45° or more from the
horizontal. This position prevents dripping grease and facilitates collecting the run-off grease in a drip pan, unusually
installed with a lter.
A strong exhaust fan tends to create a vacuum in the room and may interfere with burner performance or may extinguish
pilot ames. Fresh air openings approximately equal to the fan area will relieve such a vacuum. The exhaust fan should
be installed at least 609.6 mm (24”), above the vent opening at the top of the unit.
NOTICE
Due to the variety of problems encountered by outside weather conditions, venting by canopies or wall fans is
preferred over any type of direct venting.
If the unit is connected directly to an outside ue, a CSA design certied down draft diverter must be installed.
In case of unsatisfactory performance on any appliance, check the appliance with the exhaust fan turned OFF. Do this
only long enough to check whether doing so corrects any problems with equipment performance. Then turn the exhaust
fan back on and let it run to remove any exhaust that may have accumulated during the test.
GAS SUPPLY
The broiler is design-certied for operation on natural or propane gases. The broiler is shipped congured and adjusted for
the type of gas specied by the purchaser, which is indicated on the serial plate (see Figure 1). Connect the broiler ONLY
to the type of gas for which it is congured and adjusted.
Models with a rear gas connection have a 1” rear gas connection to an external regulator that is located at the rear bottom
corner on the right side. Models with a front gas supply are connected by unions assembled to the front manifold.
Minimum supply pressure is 7” W.C. for natural gas, 11” W.C. for propane. An external pressure regulator and shutoff
valve are provided. If using a exible-hose gas connection, the inside diameter of the hose must not be smaller than the
connector on the broiler, and must comply with ANSI Z21.69. Provide an adequate means of restraint to prevent undue
strain on the gas connection. Test pressure should not exceed 14” W.C.
If applicable, the vent line from the gas appliance pressure regulator must be installed to the outdoors in accordance with
local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA-B149.2, as applicable.
An adequate gas supply is imperative. Undersized or low-pressure lines will restrict the volume of gas required for
satisfactory performance. A 1/8” pressure tap is located on the manifold to measure the manifold pressure. The supply
line to the broiler should be no smaller than the inside diameter of the pipe on the broiler to which it is connected.
OWNER’S MANUAL 1190950 REV 2 (11/14)
PAGE
5
OF 22
INSTALLATION
STEAKHOUSE BROILER
INSTALLATION
NOTICE
These installation procedures must be followed by qualied personnel or warranty will be void.
Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association, Inc.
states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to installation
requirements for equipment. Therefore, installations should comply with all local codes.
The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code CAN/CGA-B149.2,
as applicable, including:
1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa) or 35 mbar (14” W.C).
2. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45
kPa) 35 mbar (14” W.C).
NOTICE
EXHAUST FANS AND CANOPIES: It is recommended that the Southbend equipment be installed under a ventilation
hood. Consult local codes for proper installation of hoods. Proper ventilation is the owner’s responsibility. Any problem
due to improper ventilation will not be covered by warranty.
NOTICE
In the Commonwealth of Massachusetts all gas appliances vented by either mechanical systems or ventilation hoods
shall comply with 248 CMR interlocking requirements.
STEP 1: UNPACKING
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE
All containers should be examined for damage before and during unloading. The freight carrier has assumed
responsibility for its safe transit and delivery. If damaged equipment is received, either apparent or concealed, a claim
must be made with the delivering carrier.
Apparent damage or loss must be noted on the freight bill at the time of delivery. The freight bill must then be signed
by the carrier representative (Driver). If the bill is not signed, the carrier may refuse the claim. The carrier can supply
the necessary forms.
A request for inspection must be made to the carrier within 15 days if there is concealed damage or loss that is not
apparent until after the equipment is uncrated. The carrier should arrange an inspection. Be certain to hold all
contents plus all packing material.
For each section, do the following:
1. Cut the banding straps and remove the corrugated cardboard surrounding the Southbend product. Do not remove
any tags or labels attached to the equipment until the unit is installed and working properly.
2. Cut the banding strap holding the equipment to the wooden skid.
3. If installing the broiler on a stand, go to Step 2a.
If installing the broiler on a countertop, go to Step 2b.
6
PAGE
OF 22
OWNER’S MANUAL 1190950 REV 2 (11/14)
STEAKHOUSE BROILER
A
I
INSTALLATION
STEP 2A: MOUNT ON HEAVY DUTY STAND AND ATTACH RESTRAINT
The stand is crated separately, but is shipped with the broiler. Depending on the shipping requirements, the broiler may
already be assembled to the stand.
NOTICE
For an appliance equipped with casters, (1) the installation shall be made with a connector that complies with the
Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or Connectors for Moveable Gas Appliances,
CAN/CGA-6.16, and a quick-disconnect device that complies with the Standard for Quick-Disconnect Devices for
Use With Gas Fuel, ANSI Z21.41, or Quick Disconnect Devices for Use with Gas Fuel, CAN1-6.9, (2) adequate
means must be provided to limit the movement of the appliance without depending on the connector and the quickdisconnect device or its associated piping to limit the appliance movement, and (3) the restraining means should be
attached to a frame member on the back of the appliance.
1. Secure the restraining-cable bracket (item “B” in Figure 4) to a wall stud located as close as possible to the connection
point of the gas-supply line (and the pressure-regulator vent line, if a vent line is in use). Use four #12 screws (items
“C”) and plastic anchors (items “A”), if necessary.
2. Install eye-bolt (item “F”) to a frame member on the rear of the appliance. After checking carefully behind the frame
member for adequate clearance, drill a 1/4” hole through the frame member.
3. Thread hex nut (item “G”) and slide the washer (item “H”) onto the eye-bolt. Insert the eye-bolt through the 1/4” drilled
hole and secure with a washer (item “H”) and nylon lock nut (item “I”).
4. Using the spring-loaded snap hooks, attach the restraining cable to the bracket and the eye-bolt.
5. Using the cable clamp (item “D”), adjust the restraining-cable extended length to prevent over-bending or kinking of
the gas line (and vent line, if in use).
Figure 2
Installation of Restraint
C
B
H
G
F
E
OWNER’S MANUAL 1190950 REV 2 (11/14)
D
PAGE
7