INFRARED CHESSE MELTER
A Middleby Company
Standard Features
- Schwank infra-red burners adjustable from 9,000 BTU to
25,000 BTU
- 60 second preheat time with no waiting between loads
- Stainless steel front, sides, splasher, and interior cavity.
Aluminized top and rear
- Grid: 27 1/4” wide and 13 1/2” deep
- Mounts on 32” Platinum Range flue riser -no other support
needed
- Ideal for melted-cheese dishes, Mexican foods, casseroles,
au gratin dishes, meringues, omlets and plate warming
- Fully insulated lining
- Warranty: two years on specified operational parts and
one year on labor from date of purchase
Job Item#
PCM-32 (Sectional Mount Salamander)
(Model PCM-32)
STANDARD CONSTRUCTION SPECIFICATIONS
Exterior Finish: Exterior and interior surfaces are 430
stainless steel #3 polish. Aluminized steel back and top.
Assembly: Insulated top, bottom, sides and back to retain
heat. Shelf wires are chrome plated, rounded and wrapped.
Two shelf positions with safety locks. One shelf comes
standard with unit. Cheese Melter is serviceable from the
front.
Form PCM-32
A Middleby Company
Cheese Melter: Mounts on flue riser of a sectional range.
Schwank infrared burner tiles have adjustable BTU’s from
9,000 to 25,000 -depending upon products being heated.
Preheat time is 60 seconds. Front opening is 28” wide and 8
1/2” high.
05/03 Printed in USA
Models:
16"
(406)
PCM-32
24" (610)
9.25" (235)
40.5" (1030)
19-1/4"
(489)
31" (787)
THGIEW&SNOISNEMIDETARCGNIPPIHS
ledoMhtdiWthgieHhtpeDemuloVthgieW
63
72
23-MCP
)419(
22
)686(
)955(
tfuc4.21
)muc53.0(
The cheese melter and flue riser assembly is
shown here mounted on a six-burner open top
range with a convection oven base.
sbl012
)gk3.59(
19-1/4"
(489)
36"
(914)
32" (813)
31" (788)
52-3/4"
(1340)
72"
(1829)
(406)
16-3/4"
(425)
35-3/4" (908)
16"
UTILITY INFORMATION
SAG
ledoM
23-MCP000,52000,52
larutaN
ruoH/UTB
GAS: This unit has a 1/2” rear gas connection with a male NPT
connector. Minimum supply pressure is 7” W.C. for natural gas and
11” W.C. for propane. Unit requires an external pressure regulator
and shut-off vavle to be ordered separately. If using a flexible hose
gas connection, the I.D. of the hose must not be smaller than the
connector on the unit and must comply with ANSI Z21.69, providing an
adequate means of restraint to prevent undue strain on the gas
connection.
enaporP
ruoH/UTB
(internal piping to front manifold is an option)
Gas Connection
2-3/4" (70)
62-1/4"
(1581)
MISCELLANEOUS
- Minimum clearance from noncombustible construction is
zero, except on top where 12” clearance is required for proper
venting. Minimum clearance from combustible construction is
6” on sides and 6” on rear.
- Install under vented hood.
- Check local codes for fire and sanitary regulations.
NOTICE:
Southbend has a policy of continuous product research and
improvement. We reserve the right to change specifications
and product design without notice. Such revisions do not
entitle the buyer to corresponding changes, improvements,
additions or replacements for previously purchased
equipment.
Stainless steel exterior bottom
T
Sloped encloser
T
Form PCM-32
OPTIONS AND ACCESSORIES
Interpiping of gas connection to sectional
T
range base
Riser assembly for mounting over Sectional
T
Range
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.
1100 Old Honeycutt Rd., Fuquay-Varina, NC 27526
www.southbendnc.com