Southbend OB-4-1-48-E User Manual

Ti lT in g Oy s T e r CO O k e r
w i T h el e C T r i C BO i l e r Ba s e
Mo d e l Ca p a C i t y
OB 4-1-48-E 1 quart x 4
OB 4-2-54-E 2 quart x 4
OPERATION SHALL BE BY:
Electrically heated steam boiler operating at 15 psi (103kPa) and rated at:
24 kw (Standard) 36 kw (Optional at extra cost) 42 kw (Optional at extra cost)
The steam boiler shall be equipped for operation on:
208 VAC, 3 phase, 60 Hz 240 VAC, 3 phase, 60 Hz
Job Item#
SPECIFICATIONS:
Shall be a Model _______________________________, consisting of 4 one quart or 4 two quart direct steam, tilting oyster cookers. Oyster cookers shall be constructed of type 304
stainless steel with a #4 nish, one piece welded construction.
Each cooker shall be equipped with a tilt handle and heat resistant know, allowing the cooker to be tilted forward 90o for complete emptying. The stainless steel mounting legs shall have the steam supply and condensate within the legs and the tight left
tted with the steam control valve for the oyster cooker. Oyster
cookers are standard with a stainless steel left off cover. The oyster cookers are mounted on a cabinet base with full
perimeter angle frame, reinforced counter, spillage sink complete with drain and drain screen, boiler mountings, gas boiler with controls, hinged doors with magnetic catches, removable side
panels and 6” (152mm) stainless steel legs tted with adjustable bullet feet. All #4 nish stainless steel exterior. Steam manifold concealed within cabinet tted with steam trap and safety
valve.
OPTIONAL ITEMS AT EXTRA COST:
Single pantry faucet with swing spoutDouble pantry faucet with swing spoutNylon cutting board 380 VAC, 3 phase, 50 Hz 415 VAC, 3 phase, 50 Hz 480 VAC, 3 phase, 60 Hz
Form OB-E Rev 0 (12/07)
www.yatesgd.com www.yatesgraphicdesign.com
Printed in USA
Models:
OB 4-1-48-E OB 4-2-54-E
NOTE: Faucet is optional
DIMENSIONS
Mo d e l Un i t s a B C d e F G H J K l M n o
OB 4-1-48-E OB 4-2-54-E
in
(mm)
30”
(769)
55.25” (1381)
15.75” (394)
39.5” (988)6”(150)6”(150)
7.5”
(188)
14.5” (363)
10.5” (263)
14”
(350)
19.25” (481)
1.5” (38)
2.5” (63)
SERvICE CONNECTIONS
– ELECTRICAL CONNECTION: 1/2” (13mm) conduit connection to controls
– DRAIN: 2” (51 mm) IPS piped to open oor drain. No solid connection.
– COLD WATER: 3/8” (10mm) O.D. tubing at 25-50 PSI (170-345 kPa)
IN (MM)
3.75” (94)
Form OB-E Rev 0 (12/07)
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com
www.yatesgd.com www.yatesgraphicdesign.com