Gas steam
t
iltinG Kettle
Model CapaCity
KTLG-20 20 Gallon 76 Liter
KTLG-30 30 Gallon 114 Liter
KTLG-40 40 Gallon 152 Liter
KTLG-60 60 Gallon 227 Liter
OPERATION SHALL BE BY:
High efciency power burner system for operation on 115
VAC, 1 Phase, 50/60 Hz.
Natural gas
L.P. gas
Job Item#
Shown with optional spring
assist cover and faucet
SPECIFICATIONS:
Shall be a Southbend Model ___________________________,
self-contained, gas red, fully insulated steam jacketed kettle,
ASME Code stamped, National Board Registered, AGA, CGA
and NSF certied for operation up to 50 PSI. A double wall
interior shall form a steam jacket around the lower 2/3 of the
kettle. The jacket enclosure shall contain factory sealed, distilled
water. The kettle interior on models 20, 30 and 40 gallon models
shall be stainless stell, type 316 for high acid content cooking.
The kettle interior on 60 gallon models shall be type 304 stainless
steel. Kettle exterior is fully insulated. The bottom of the kettle
shall be of hemispherical design for superior heat circulation.
The recessed control panel is located on the front right of the
unit, in full view of the operator and easy to use. Standard
controls include direct immersion thermostat for operation at a
temperature range of 165°F to 275°F (74°C to 135°C) at 50 psi,
water sight glass, cooking light, pressure gauge and electronic
ignition with ignition indicator light. Comes standard with 3 piece
split faucet bracket. Safety features include low water shut off
with indicator light, pressure switch, pressure relief valve and a
100% safety gas shut off valve.
The kettle shall pivot on trunnions connected to the tilt
mechanism and control consoles. The tilt mechanism shall allow
the kettle to tilt past 90° for complete emptying. The console
shall be drip proof, stainless steel clad and shall be supported
on all welded, 1-5/8” (41 mm) diameter stainless steel legs with
anged feet for securing to the oor.
*
OPTIONAL ITEMS AT EXTRA COST:
Type 316 stainless steel liner (for KTLG-60 only)
208-240 VAC operation (specify voltage)
Spring assist stainless steel cover (CH-)
2" (50 mm) tangent draw-off valve (TVT-2) with
perforated strainer (TPS)
3" (76 mm) tangent draw-off valve (TVT-3) with
perforated strainer (TPS)
2” (50 mm) dairy draw-off valve (DDO-2T)
3” (76 mm) dairy draw-off valve (DDO-3T)
Etched gallon markings (GM-)
Etched litre markings (LM-)
Single pantry faucet with swing spout (SF-18)
Double pantry faucet with swing spout (DF-18)
Casters
Correctional package
ACCESSORIES:
Triple basket assembly (TBA-)
Graduated measuring strip (CMS-)
Solid stainless steel disc for draw off (TSS-)
Perforated strainer for draw-off valve (TPS-)
Strainer hook (SH-)
Pour strainer (TKS-)
Pan carrier
Draw-off valve hose kit (DVHK-)
Form KTLG Rev 4 (July/2015)
www.yatesgd.com www.yatesgraphicdesign.com
Models:
KTLG-20 KTLG-30 KTLG-40 KTLG-60
Model sHippinG WeiGHt
KTLG-20 700 lbs. [318 kg]
KTLG-30 900 lbs. [408 kg]
KTLG-40 930 lbs. [422 kg]
KTLG-60 1142 lbs. [51 kg]
SERvICE CONNECTIONS
– GAS CONNECTION: Supply Gas through 3/4” pipe. A gas shut off valve must be installed in supply piping convenient and adjacent to appliance.
– ELECTRICAL CONNECTION : Unless otherwise specied, eld wire electrical connection to be 120 volts, 60 Hz, 1 phase with grounding wire. Unit
furnished with 6’ cord and 3 prong plug. Total maximum amps 4.0.
– COLD WATER: 3/8” (10 mm) tubing to faucet (optional)
– HOT WATER: 3/8” (10 mm) tubing to faucet (optional)
DIMENSIONS
Model CapaCity Units a B C d e F G H J K l M n
KTLG-20
KTLG-30
KTLG-40
KTLG-60
20 gallons
(76 liters)
30 gallons
(114 liters)in(mm)
40 gallons
(152 liters)in(mm)
60 gallons
(227 liters)in(mm)
in
(mm)
20”
(508)
26”
(660)
26”
(660)
30”
(762)
48.13”
(1222)
55.25”
(1403)
55.25”
(1403)
59”
(1499)
40.63”
(1032)
43.63”
(1108)
43.63”
(1108)
45.63”
(1159)
19”
(483)
16.5”
(419)
16.5”
(419)
17.88”
(454)
40.13”
(1019)
39”
(991)
43.25”
(1099)
43.88”
(1115)
76.5”
(1943)
73.75”
(1873)
76”
(1930)
82”
(2083)
16.5”
(419)
15.5”
(394)
15.5
(394)
19.5”
(495)
24”
(610)
22.25”
(565)
22.25”
(565)
22.25”
(565)
11”
(279)
7.5”
(191)
7.5”
(191)
5.5”
(140)
22”
(559)
21”
(538)
23”
(584)
23”
(584)
40.5”
(1029)
38.13”
(968)
42.5”
(1080)
45.5”
(1156)
18.38”
(467)
17.88”
(454)
22.13”
(562)
24.75”
(629)
UTILITIES
Model
KTLG-20 80,000 23.4
KTLG-30 100,000 29.3
KTLG-40 100,000 29.3
KTLG-60 120,000 35.2
BtU/Hr. kW/HR. sUpply pipe pressUre (W.C.)
Gas sUpply
Natural
6”-14” (152-356 mm)
Propane
11”-14” (279-356 mm)
MiniMUM ClearanCe *
Sides
Back
0” [0 mm]
4” [102 mm]
* For use on non-combustible oors only.
25.5”
(648)
28.5”
(724)
28.5”
(724)
30.5”
(775)
Form KTLG Rev 4 (July/2015)
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com
.