Southbend KSLG-20, KSLG-40, KSLG-60 User Manual

GAS STEAM
KETTLE STATIONARY
MODE L CAPACITY
KSLG-20 20 Gallon 76 Liter
KSLG-40 40 Gallon 152 Liter
KSLG-60 60 Gallon 227 Liter
OPERATION SHALL BE BY:
Natural or L.P. gas, A.S.M.E. code stamped for operation up to 50 psi. The steam kettle temperature ranges shall be between 150ºF to 285ºF. Burners shall be serviceable, high efficiency stainless steel with no shutter adjustment.
Job Item#
SPECIFICATIONS:
Shall be a Model ___________________________________, gas fired, self-contained steam jacketed kettle, AGA and CGA design certified, NSF approved. The unit comes standard with a hinged stainless steel cover. The 60 gallon kettle comes standard with a spring assisted cover. The kettle shall be constructed with an exterior of type 304 stainless steel, #4 sanitary finish and 6" stainless steel adjustable legs. The interior kettle liner shall be a one piece welded construction made with type 304 stainless with #4 sanitary finish, 2/3 jacketed and shall be furnished with a 2" tangent draw off valve as standard. The recessed control panel is located on the front side of the unit in full view of the operator and is easy to use. Standard controls include a direct immersion thermostat, water sight glass, cooking light, pressure gauge and low water indicator light. Safety features shall include a low water cut off, pressure relief valve, pressure switch and a 100% safety gas shutoff valve.
OPTIONAL ITEMS AT EXTRA COST:
Stainless steel tri basket, TBA-1Electronic ignitionSingle pantry faucet with swing spout, SF-12Double pantry faucet with swing spout, DF-12Strainer hook316 Stainless steel liner for high acid content productsGraduated measuring strip or etched gallon markings3" draw-off valve, TVS-3Tangent draw-off strainer, TPS or TSSSpring assist for 20 + 40 gallonCastersDairy valvePrison package220 volt
Form KSLG Rev 0 (01/07)
www.yatesgd.com www.yatesgraphicdesign.com
08/04 Printed in USA
Models:
KSLG-20 KSLG-40 KSLG-60
DIMENSIONS
MODE L CAPACITY UNITS A B C D E F G H J K
KSLG-20
KSLG-40
KSLG-60
- GAS CONNECTION: One 1” male connection (for location, see drawing) Natural Propane
– ELECTRICAL CONNECTION - STANDARD: 115/60/1 - furnished with 6 ft cord w/3-prong plug. Total maximum amps 2.0
– ELECTRICAL CONNECTION - OPTIONAL: 208/60/1 or for use on 3 (190 to 219 volts) - supply must be wired to unit - see drawing.
Total maximum amps 1.0
– ELECTRICAL CONNECTION - OPTIONAL: 236/60/1 or for use on 3 (220 to 240 volts) - supply must be wired to unit - see drawing.
Total maximum amps 1.0
20 gallons
(76 liters)in(mm)
40 gallons
(152 liters)in(mm)
60 gallons
(227 liters)in(mm)
20"
(508)
26"
(660)
30"
(762)
27.5" (698)
32.5" (825)
36.5" (927)
40"
(1016)
44"
(1118)
49.5"
(1257)
SERVICE CONNCETIONS
32"
(813)
38.5" (978)
42"
(1016)
3"
(76)
2"
(51)
2.5" (63)
19"
(483)
19"
(483)
21.5" (546)
64"
(1626)
72"
(1829)
85"
(2159)
24"
(610)
29"
(737)
35"
(889)
30.5" (775)6"(152)
35"
(889)6"(152)
39"
(991)8"(203)
Form KSLG Rev 0 (01/07)