Southbend KDCT-10 User Manual

Direct Steam
counter tilting Kettle
Model CapaCity
KDCT-6 6 Gallon 23 Liter
KDCT-10 10 Gallon 38 Liter
KDCT-12 12 Gallon 45 Liter
KDCT-20 20 Gallon 76 Liter
OPERATION SHALL BE BY:
Direct steam at a minimum of 5 PSI (34 kPa) and a maximum of 50 PSI (345 kPa).
STANDARD FEATURES:
Reversible tilt handle
Type 316 stainless steel liner
Steam control valve
Job Item#
DC-6 shown.
SPECIFICATIONS:
Shall be a Model ________________________________, direct connected, steam, counter top tilting kettle. A double wall kettle interior shall form a steam jacket around the lower 2/3 of the kettle. The bottom of the kettle shall be of hemispheric design for superior heat transfer.
The tubular stainless steel mounting legs shall have the tilt bearings, steam supply and condensate return pipes completely concealed within the leg members and the right leg will be tted with a steam control valve. A single support leg with nylon foot shall support the kettle in the upright position. The sealed stainless steel tilt mechanism bearings shall permit the kettle to tilt forward past 90° for complete emptying. A removable operating handle with heat-proof knob shall be mounted on the left or right. Construction shall be all welded satin nish stainless steel, type 304. Standard features include type 316 stainless steel liner for use with high acid content products. The kettle shall be NSF Certied, ASME code stamped and National Board registered.
OPTIONAL ITEMS AT EXTRA COST:
Etched gallon markings (GM-)
Etched liter markings (LM-)
24” wide oor stand with sliding shelf (KEDC-24)
36” wide oor stand with sliding shelf (KEDC-36)
30” wide oor stand with sliding drain pan (KEDC-30SD)
Correctional Package
ACCESSORIES:
One piece lift off stainless steel cover (C-)
Stainless steel perforated basket (SSB-)
Pour lip strainer (TKS-)
Steam control assembly (STA-3) consisting of line strainer,
steam trap and safety valve
Contoured measuring strip (CMS-)
Pressure reducing valve (PRV)
Form KDCT Rev 1 (November/2010)
www.yatesgd.com www.yatesgraphicdesign.com
Models:
KDCT-6 KDCT-10 KDCT-12 KDCT-20
DC-20
SERVICE CONNECTIONS
– STEAM SUPPLY” 1/2” IPS (13 mm) 5-45 PSI (34-310 kPa) [Pressure
reducing valve is required if incoming pressure exceeds 50 PSI (345 kPa)]
- CONDENSATE RETURN: 1/2” IPS (13 mm)
Model sHippinG WeiGHt MiniMUM ClearanCe
KDCT-6 44 lbs. [20 kg]
KDCT-10 61 lbs. [28 kg]
KDCT-12 70 lbs. [32 kg]
KDCT-20 95 lbs. [43 kg]
SIDES
BACK
1” [25mm]
3” [76mm]
DIMENSIONS
Model CapaCity Units a B C d e F G H J K l M n o p Q
KDCT-6
KDCT-10
KDCT-12
KDCT-20
6 gallons (23 liters)in(mm)
10 gallons
(38 liters)in(mm)
12 gallons
(46 liters)in(mm)
20 gallons
(76 liters)in(mm)
12”
(305)
16”
(406)
16”
(406)
21”
(533)
14.5” (368)
15”
(381)
17”
(432)
18”
(457)
19.5” (495)
18.5” (470)
20.5” (521)
26.5” (673)
13.75” (349)5”(127)
13.75” (349)7”(178)
13.75” (349)7”(178)
23.5”
1.5”
(597)
(38)
7.5”
(191)
7.75” (197)
7.75” (197)
6.25” (159)
15.12”
8.5”
(384)
(216)
19.12” (486)9”(229)
19.12” (486)9”(229)
24.12”
15.25”
(613)
(387)
12.25” (311)
16.25” (413)
16.25” (413)
15.75” (400)
10.38” (264)
8.88” (225)
10.88” (276)
10.5” (267)
30.25” (768)4”(102)
32.25”
2.38”
(819)
(60)
39.5”
2.38”
(1003)
(60)
40.5”
7.5”
(1029)
(191)
4.38” (111)
4.88” (124)
4.88” (124)
11.12” (283)
34.12” (867)0”0 mm
33.12” (841)0”0 mm
35.12” (892)0”0 mm
42.38”
1.5”
(1076)
(38)
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.
16”
(406)
19.25” (489)
19.25” (489)
26”
(660)
Form KDCT Rev 1 (November/2010)
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com
Loading...