Southbend GCX-2-10 User Manual

GAS COMPARTMENT STEAMER
WITH SOLID STATE CONTROLS
KETTLE
AND
Model Compartments Capacity
GCX-2-6 2 4-12 Pans
GCX-2-10 2 4-12 Pans
OPERATION SHALL BE BY:
Gas heated steam boiler operating at 15 psi (103 kPa) and rated at:
200,000 BTU (standard)
250,000 BTU (optional at extra cost)
The steam boiler shall be equipped for operation on:
Natural Gas
Propane Gas
The controls shall be equipped for operation on:
115 VAC, 1 Phase, 60 Hz
Job Item#
Shall be a Model ___________________________________, Convection Steamer complete with 6 or 10 Gallon Kettle on a
common base with gas steam generator. Solid State touch control panel, one per compartment each with 99 minute capacity digital timer. Compartments designed for ease of cleaning, front drain to collect condensate from open doors. Steamer, Kettle, cooking compartments, doors and table top constructed of 304 stainless steel, exterior in a No. 4 finish. Each cooking compartment is insulated, the doors have a removable inner liner of stainless steel with full perimeter gasket seal, an outer liner of one piece all welded stainless steel and a positive lock and seal mechanism with spring release. The door opening is 10 x 14 (254 x 356mm). Each compartment has removable stainless steel pan supports.
Control housing is accessable through a fully removable side panel. Controls consist of illuminated ON/OFF power switch, 99 minute timer which sounds an audible signal at end of cooking cycle. Steam to the chamber is cut off when door is open during the cooking cycle and reactivated when door is closed. The Kettle is conveniently mounted beside compartment cooker complete with let mounted steam control valve.
The cabinet base has a full perimeter angle frame, reinforced counter & boiler mountings, gas boiler with controls, all stainless steel exterior hinged doors and 6" stainless steel legs with adjustable bullet feet.
OPTIONAL ITEMS AT EXTRA COST:
12" x 20" x 2-1/2" perforated stainless steel pan
12" x 20" x 4" perforated stainless steel pan
12" x 20" x 4" solid stainless steel pan
Spray and rinse assembly
Steam take-off kit
Automatic boiler blowdown
Kettle type 316 Liner
220 or 240 VAC, 1 Phase, 50 Hz
Form GCX-2-6/10
www.yatesgd.com www.yatesgraphicdesign.com
08/04 Printed in USA
Models:
GCX-2-6 GCX-2-10
SERVICE CONNCETIONS
– COLD WATER: 1/2" (13 mm).
– DRAIN: 2" (51 mm) IPS piped to open floor drain. No solid connection.
– ELECTRICAL CONNECTION: 1/2" (13 mm) conduit connection to controls. 2 Amps per compartment, 120-60-1 or 220-50-1.
– STEAM TAKE-OFF CONNECTION: 3/4" (19 mm) optional to operate adjacent equipment.
– GAS CONNECTION: 3/4" (19 mm) IPS.
DIMENSIONS
MODEL UNITS A B C D E F G H J K L M N O P Q R S
GCX -2-6
GCX-2-10in(mm)
44"
(1100)
48"
(1200)
33"
(838 )
14"
(357 )6"(152)
28"
58"
(711)
(1479)6"(152 )8"(203 )
14"
22"
(357)
(559)2"(51)4"(102)6"(152 )2"(51)4"(102)5"(127)6"(152)
UTILITIES
MODEL BTU/HOUR KCAL/HOUR FUEL WATER COLUM N PRESSURE
GCX-2-6 200,000 50,632
GCX-2-10 250,000 63,291
Natural 4" (102 mm)
Propane 11" (279 mm)
Natural 4" (102 mm)
Propane 11" (279 mm)
Form GCX-2-6/10
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com
www.yatesgd.com www.yatesgraphicdesign.com
Loading...