Two ComparTmenT
16 Pan Steamer
SPECIFICATIONS:
Shall be a Model GCX-16 convection steamer with gas steam
boiler. The steamer shall be constructed of satin nish stainless
steel, type 304, with a cooking chamber of one piece all welded
316 stainless steel. The doors shall have a removable inner
liner of stainless steel with full perimeter gasket seal, an outer
liner of one-piece all welded stainless steel and a positive lock
and seal mechanism. The door opening shall be 14” x 26.5”
(356 x 673mm).
The steamer shall be provided with removable stainless steel
pan supports and a stainless steel drip trough connected to the
drain to collect condensate when door is opened.
The control housing shall be constructed of stainless steel with
a full access removable panel. The timing of each cooking
compartment shall be independently controlled by a “60” minute
timer, a green ready pilot light and a red cook pilot light. At the
end of the cooking cycle an audible signal is sounded. Steam
ow to the cooking chamber shall be interrupted when the door
is opened during the cooking cycle and shall be reactivated
when the door is closed.
The convection steamer shall be mounted on a cabinet base
with full perimeter angle frame, reinforced counter, and boiler
mountings, gas boiler with controls, all stainless steel exterior,
hinged doors and 6” (152mm) stainless steel legs with adjustable
bullet feet for securing to the oor.
with
ComPartment Pan CaPaCity
model
GCX-16 8 4
OPERATION SHALL BE BY:
Gas heated steam boiler, operating at 15 psi (103kPa)
rated at 300,000 BTU.
The gas boiler shall be equipped to operation on:
Natural gas
Propane gas
The controls shall be equipped for operation on:
115 VAC, 1 Phase, 60 Hz
OPTIONAL ITEMS AT EXTRA COST:
Automatic boiler blow down
220 or 240 VAC, 1 Phase, 50 Hz
Two water lines (boiler feed and condensate)
De-lime piping assembly (DPA-1)
Stainless steel frame
Stainless steel back on cabinet
California State boiler code requirement
CSD-1
Electronic ignition
Load compensate timer
ACCESSORIES:
Spray and rinse assembly
Adjustable anged feet
Ball oat trap
Water in strainer
Steam take off kit
2-1/2” 4” 4” & 1” 4” & 2-1/2”
Pan dePth
Cabinet baSe
2 x 4”
2 x 1”
2 x 4”
1 x 2-1/2”
Job Item#
Form GCX-16 Rev 5 (March/2015)
www.yatesgd.com www.yatesgraphicdesign.com
Models:
GCX-16
24” (610)
8.75” (222)
13.5” (343)
REAR FLANGED FOOT DETAIL
2 EQUALLY SPACED
∅ 7/16” (11MM) HOLES
ON 2.5’ (63MM) B.C.
S
G
C
D
5.75” (146)
6.25” (159)
C
4.75” (121)
2.5” (64)
10” (254)
62” (1575)
28” (711)
6” (152)
SERVICE CONNECTIONS
model
GCX-16 990 lbs. [449 kg]
3” (76)
ShiPPinG weiGht
(36” Cabinet)
D
29.75” (756)
36” (914)
26.75” (679)
8” (203)
6.75” (171)
S
G
SIDES
BACK
m
inimum ClearanCe
33” (838)
24.75” (629)
IN (MM)
0
0
– GENERATOR: COLD WATER: 3/8” (10 mm) O.D. tubing at 25-50 psi (170-345 kPa).
– CONDENSATE: COLD WATER: 3/8” (10 mm) O.D. tubing at 25-50 psi (170-345 kPa).
– DRAIN: 2” (51 mm) IPS piped to open oor drain. No solid connection.
– ELECTRICAL CONNECTION: 1/2” (13 mm) conduit connection to controls. 2 Amps per compartment, 120-60-1 or 220-50-1.
– STEAM TAKE-OFF CONNECTION: 3/4” (19 mm) optional to operate adjacent equipment.
– GAS CONNECTION: 3/4” (19 mm) IPS.
UTILITIES
model
GCX-16
min 4” (102 mm)
water Column PreSSure btu/hr kw/hr
Natural
Propane
min 11” (279 mm)
WATER QUALITY STATEMENT
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a local water
treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Total dissolved solids ....................Less than 60 PPM
Total alkalinity ................................Less than 20 PPM
Silica ...............................................Less than 13 PPM
Chlorine .........................................Less than 1.5 PPM
pH Factor ......................................7.0 - 8.5
Water which fails to meet these standards should be treated by installation of water conditioner.
GaS SuPPly
250,000 73.3
300,000 87.9
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.
CONTACT SOUTHBEND FOR WATER QUALITY SOLUTIONS.
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com
Form GCX-16 Rev 5 (March/2015)
.