Gas Compartment steamer
W
ith Kettle and Gas Fired
s
team Boiler
Job Item#
SPECIFICATIONS:
Shall be a Southbend model ____________________________,
convection steamer complete with 6 or 10 Gallon Kettle on a modular
gas red steam boiler base, with stainless steel type 304 exterior and
#4 nish, deck mounted faucet valve, swing nozzle and integral sink
with common drain.
The convection steamer shall have doors with a removable inner liner
of stainless steel, full perimeter gasket seal, outer shell of one piece, all
welded, stainless steel, positive lock and seal mechanism and a stainless
steel drip trough connected to the drain in order to collect condensate
when doors are opened. Each cooking chamber shall be constructed
of all welded type 316 stainless steel, fully insulated and provided with
removable stainless steel pan supports and shall be:
GCX-2S: 13.875”W x 10.875”H x 19.875”D (352 mm x 276 mm x 504 mm).
GCX-10S: 13.875”W x 17.375”H x 19.875”D (352 mm x 441 mm x 504 mm).
Steamer controls shall be accessible through a fully removable side
panel and each compartment shall include a 60 minute mechanical timer
with ready and cooking pilot light and shall interrupt steam ow to the
chamber when the compartment door is opened during cooking cycle
and shall be reactivated when the door is closed. An audible signal will
sound at the end of the cooking cycle.
The cabinet base with gas boiler and controls shall be provided with full
perimeter painted angle frame, reinforced kettle and boiler mountings,
hinged doors with magnetic latch and 6” (152 mm) stainless steel legs
tted with adjustable bullet feet on the front and adjustable anged feet
on the rear for securing unit to the oor. Boiler controls shall include
automatic water level control, pressure gauge, water gauge glass,
operating pressure control, safety high-limit pressure control, safety
relief valve and cathodic protector. The boiler shall be ASME code
stamped and National Board registered. Unit comes standard with a
split water line, CSD-1 boiler code, “Y” - strainer, electronic ignition,
and automatic blowdown.
Model description
GCX-2S-6
GCX-2S-10
GCX-10S-6
GCX-10S-10
6 pan steamer with 6 gallon
kettle and 250,000 BTU boiler.
6 pan steamer with 10 gallon
kettle and 250,000 BTU boiler.
10 pan steamer with 6 gallon
kettle and 250,000 BTU boiler.
10 pan steamer with 10 gallon
kettle and 250,000 BTU boiler.
pan capacity per coMpartMent
1” 2-1/2” 4” 6”
10 5 3 2
pan depth
6 3 2 1
OPERATION SHALL BE BY:
Gas heated steam boiler operating at 9 -11 psi (62 - 76 kPa).
The controls shall be equipped for operation on 115 VAC,
single phase 50/60 Hz.
Natural Gas
LP Gas
OPTIONAL ITEMS AT EXTRA COST:
300,000 BTU
208-240 VAC operation (specify voltage)
Stainless steel rear panel
Stainless steel frame
Correctional package
Adjustable front anged feet
Load compensating timers
ACCESSORIES:
Spray and rinse assembly
Steam take-off kit (STOK)
Form GCX2-6 Rev 5 (March/2015)
www.yatesgd.com www.yatesgraphicdesign.com
Models:
GCX-2S-6 GCX-2S-10 GCX-10S-6 GCX-10S-10
Model shipping Weight
GCX-2S-6 980 lbs. [445 kg.]
GCX-10S-6 1000 lbs. [454 kg.]
GCX-2S-10 1030 lbs. [467 kg.]
GCX-10S-10 1020 lbs. [462 kg.]
SERVICE CONNECTIONS
– ELECTRICAL CONNECTION: 1/2” (13 mm) conduit connection to controls. 120 VAC-60Hz-1PH.
2 Amps per compartment or as specied on data plate.
– BOILER FEED WATER: 1/2” (13 mm) NPT at 25-50 PSI (170-345 kPa).
– CONDENSATE COLD WATER: 1/2” (13 mm) NPT at 25-50 PSI (170-345 kPa) (OPTIONAL)
– GAS CONNECTION: 3/4” (19 mm) IPS supply line required.
– STEAM TAKE-OFF CONNECTION: 3/4” (19 mm) IPS optional to operate adjacent equipment.
– HOT WATER: 3/8” (10 mm) O.D. tubing at 25-50 PSI (170-345 kPa).
– DRAIN: 2” (51 mm) IPS piped to open oor drain. No solid connection.
– SINK DRAIN: 1 1/8” (29 mm) O.D. tubing.
GAS SUPPLY
BtU/hoUr kW/hoUr
250,000 73.3
300,000 87.9
natUral propane
7” - 14”
[178 mm - 355 mm]
Model a B c
GCX-2S-6 59.5 [1511]
GCX-10S-6 72.5 [1842]
GCX-2-10 59.5 [1511]
GCX-10S-10 72.5 [1842]
66.13 [1680] 44 [1118]
65.13 [1654] 48 [1219]
Water colUMn pressUre
11” - 14”
[279 mm - 355 mm]
WATER QUALITY STATEMENT
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a local water
treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Total dissolved solids ....................Less than 60 PPM
Total alkalinity ................................Less than 20 PPM
Silica ...............................................Less than 13 PPM
Chlorine .........................................Less than 1.5 PPM
pH Factor ......................................7.0 - 8.5
Water which fails to meet these standards should be treated by installation of water conditioner.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.
CONTACT SOUTHBEND FOR WATER QUALITY SOLUTIONS.
INTENDED FOR COMMERCIAL USE ONLY.
.
Form GCX2-6 Rev 5 (March/2015)
NOT FOR HOUSEHOLD USE
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com