ElEctric countEr StEamEr
manual Fill, manual Drain
Model shown is an EZ24-3
SPECIFICATIONS:
Shall be a Southbend model EZ24-3 (3 pan) or EZ24-5 (5 pan)
countertop, boiler free convection steamer, c-CSA-us and NSF
certied. Unit shall be connectionless, no plumbing required.
Unit shall be constructed of satin nish 304 stainless steel with
a one piece welded 316 stainless steel cooking chamber with
coved corners. The door shall have a removable inner liner of
stainless steel with full perimeter gasket seal, an outer liner of
one-piece all welded stainless steel, and a positive lock and
seal mechanism with spring release. The steamer shall have
removable stainless steel pan supports and steam diffuser plate.
The control housing shall be constructed of stainless steel with
a full access removable panel. The controls shall include an
illuminated timed cooking/off/constant steam switch, a ready
indicator light, cooking indicator light, 60 minute electric timer
with audible alarm that signals the end of the cook cycle and a
low water indictor light with audible alarm. A door interlock switch
shall interrupt steam generation when the door is open and shall
be reactivated when the door is closed. Provide options and
accessories as indicated.
NOTE: DRAIN PAN PROVIDED BY OTHERS.
Compartment pan CapaCity
model
EZ24-3 6 3 2 1
EZ24-5 10 5 3 2
OPERATION SHALL BE BY:
Electrically heated, boiler free steam generation rated at:
9.0 kW for Model EZ24-3
15.0 kW for Model EZ24-5
The steam boiler shall be equipped for operation on:
208 VAC, 3 Phase, 50/60 Hz. *
240 VAC, 3 Phase, 50/60 Hz. *
* UNIT SHALL BE FIELD CONVERTIBLE TO SINGLE PHASE
AND ALSO CONFIGURABLE TO 2/3 RATING.
6.0 kW for Model EZ24-3
10.0 kW for Model EZ24-5
STANDARD FEATURES:
- 304 stainless steel exterior.
- 316 stainless steel cooking chamber with coved corners.
- Heavy gauge stainless steel door with full perimeter gasket.
- Positive lock and seal mechanism with spring release door.
- Illuminated cooking/off/constant steam power switch.
- Ready indicator light.
- Cooking indicator light.
- Add water indicator light with audible alarm.
- 60 minute electromechanical timer with end of cycle audible
alarm.
- 4” adjustable legs
- Removable stainless steel pan supports.
- Removable steam diffuser plate helps prevent objects from
falling into water reservoir.
- Selectable timed or constant steam cooking mode.
- Electromechanical controls.
OPTIONS AND ACCESSORIES:
220 VAC, 3 Phase, 50/60 Hz.
380 VAC, 3 phase, 50/60 Hz.
415 VAC, 3 phase, 50/60 Hz.
480 VAC, 3 phase, 50/60 Hz.
600 VAC, 3 phase, 50/60 Hz. (EZ24-3 only)
380/220 VAC, 3 Phase, 50/60 Hz 4 wire.
415/240 VAC, 3 Phase, 50/60 Hz 4 wire.
Correctional package.
120 minute timer
28” high single unit stand and double unit stacking stands
available (Contact factory for details)
Caster kit for single unit stand
Drain hose kit
1” 2-1/2” 4” 6”
pan depth
Job Item#
Form EZ24 Rev 4 (January/2014)
www.yatesgd.com www.yatesgraphicdesign.com
Models:
EZ24-3 EZ24-5
SERVICE CONNECTIONS
– ELECTRICAL CONNECTION: Ø 1 1/8”
(29 mm) hole for electrical connection. Rating to
be specied on data plate.
– DRAIN: 1/2” NPT
READYCOOKING
COOKING
CONSTANT
WATER
EZ24-3
EZ24-5
TIMED
OFF
STEAM
ADD
ELECTRICAL CHARACTERISTICS
amPS/PHaSE
moDEl kW
208V 220V 240V 380V 415V 480 V 600V
1 PH 3 PH 1 PH 3 PH 1 PH 3 PH 3 PH 3 PH 3 PH 3 PH
EZ24-3
EZ24-5
9
6
15
10
43.3
28.9
72.1
48.1
25.0
N/A
41.6
N/A
40.9
27.3
68.2
45.5
23.6
N/A
39.4
N/A
37.5
25.0
62.5
41.7
21.7
N/A
36.0
N/A
13.7
N/A
22.8
N/A
12.5
N/A
20.9
N/A
10.8
N/A
18.0
N/A
8.7
N/A
14.4
N/A
PAN CAPACITIES
incHES 1 2.5 4 6
moDEl
EZ24-3
EZ24-5 10 5 3 2 183 lbs. [83 kg]
Pan
DEPtH
mm
Total Quantity
of Pans
25 64 102 152
SHiPPing WEigHt minimum clEarancE
6 3 2 1 161 lbs. [73 kg]
SIDES
BACK
0
3
WATER QUALITY STATEMENT
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a local water
treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Total dissolved solids ....................Less than 60 PPM
Total alkalinity ................................Less than 20 PPM
Silica ...............................................Less than 13 PPM
Chlorine .........................................Less than 1.5 PPM
pH Factor ......................................7.0 - 8.5
Water which fails to meet these standards should be treated by installation of water conditioner.
*FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.*
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com
Form EZ24 Rev 4 (January/2014)
.