SPECIFICATIONS:
Shall be a Southbend model ECX-16 convection steamer with
electric steam boiler. The steamer shall be constructed of satin
nish stainless steel, type 304, with a cooking chamber of one
piece all welded 316 stainless steel. The doors shall have a
removable inner liner of stainless steel with full perimeter gasket
seal, an outer liner of one-piece all welded stainless steel and
a positive lock and seal mechanism. The door opening shall be
14” x 26.5” (356 x 673mm).
The steamer shall be provided with removable stainless steel
pan supports and a stainless steel drip trough connected to drain
to collect condensate when door is opened.
The control housing shall be constructed of stainless steel with
a full access removable panel. The timing of each cooking
compartment shall be independently controlled by a “60” minute
timer, a green ready pilot light and a red cook pilot light. At the
end of the cooking cycle an audible signal is sounded. Steam
ow to the cooking chamber shall be interrupted when the door
is opened during the cooking cycle and shall be reactivated
when the door is closed.
The convection steamer shall be mounted on a cabinet base
with full perimeter angle frame, reinforced counter, and boiler
mountings, electric boiler with controls, all stainless steel
exterior, hinged doors and 6” (152 mm) stainless steel legs with
adjustable bullet feet on front and adjustable anged feet on rear
for securing to the oor.
Two ComparTmenT, 16 pan,
C
onveCTion STeamer on 36”
C
abineT baSe wiTh eleCTriC boiler
Compartment pan CapaCity per Compartment
model
ECX-16 16 8 4
STANdArd FEATurES:
Automatic boiler blow down
Stainless steel rear panel
Split water lines (boiler feed and condesate)
Water in “Y” strainer
OPErATION SHALL BE BY:
Electrically heated steam boiler operating at 15 psi (103k Pa)
and rated at:
42.0 kw (standard)
The steam boiler shall be equipped for operation on:
208 VAC, 3 Phase, 60 Hz (not available in 48 kw)
240 VAC, 3 Phase, 60 Hz
The controls shall be equipped for operation on 115 VAC,
1 Phase, 60 Hz
OPTIONAL ITEMS AT EXTrA COST:
48.0 kw
Two water lines (boiler feed and condensate)
De-lime piping assembly (DPA-1)
Stainless steel frame
Stainless steel back on cabinet
California State boiler code requirement
CSD-1
380 VAC, 3 Phase, 50 Hz
415 VAC, 3 Phase, 50 Hz
480 VAC, 3 Phase, 50 Hz
Load compensate timer
ACCESSOrIES:
Spray and rinse assembly
Adjustable anged feet
Ball oat trap
Steam take-off kit
1” 2-1/2” 4” 4” & 1” 4” & 2-1/2”
pan depth
2 x 4”
2 x 1”
2 x 4”
1 x 2-1/2”
Job Item#
Form ECX-16 Rev 5 (September/2015)
www.yatesgd.com www.yatesgraphicdesign.com
Models:
IN (MM)
C
D
D
C
S
S
G
G
36” (914)
8.75” (222)
3.5” (89)
6.75” (171)
4.75” (121)
6” (152)
29.75” (756)
24.75” (629)
33” (838)
23” (584)
19” (483)
6” (152)
28” (711)
62” (1575)
10”
(254)
REAR FLANGED FOOT DETAIL
2 EQUALLY SPACED
∅ 7/16” (11MM) HOLES
ON 2.5’ (63MM) B.C.
ECX-16
model
ECX-16 900 lbs. [408 kg]
shipping Weight
(36” Cabinet)
m
inimum ClearanCe
SIDES
BACK
0
0
SErVICE CONNECTIONS
– ELECTRICAL CONNECTION: 1/2” (13 mm) conduit connection to controls. 2 Amps per compartment, 120-60-1 or 220-50-1.
– GENERATOR: COLD WATER: 3/8” (10 mm) O.D. tubing at 25-50 psi (170-345 kPa).
– CONDENSATE: COLD WATER: 3/8” (10 mm) O.D. tubing at 25-50 psi (170-345 kPa).
– DRAIN: 2” (51 mm) IPS piped to open oor drain. No solid connection.
– STEAM TAKE-OFF CONNECTION: 3/4” (19 mm) IPS optional to operate adjacent equipment.
ELECTrICAL CHArACTErISTICS
model phase kW
ECX-16
3 42 (Standard) 116.6 110.2 101 63.8 58.4 50.5
3 48 (Optional) - - 115.8 72.9 66.8 57.8
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a local water treatment
specialist and have the water analyzed. Your water supply must be within these general guidelines:
208V 220V 240V 380V 415V 480V
amps amps amps amps amps amps
WATEr QuALITY STATEMENT
Total dissolved solids ....................Less than 60 PPM
Total alkalinity ................................Less than 20 PPM
Silica ...............................................Less than 13 PPM
Chlorine .........................................Less than 1.5 PPM
pH Factor ......................................7.0 - 8.5
Water which fails to meet these standards should be treated by installation of water conditioner.
FAILurE Or MALFuNCTION OF THIS APPLIANCE duE TO POOr WATEr QuALITY IS NOT COVErEd uNdEr WArrANTY.
CONTACT SOuTHBENd FOr WATEr QuALITY SOLuTIONS.
Form ECX-16 Rev 5 (September/2015)
INTENdEd FOr COMMErCIAL uSE ONLY.
NOT FOr HOuSEHOLd uSE