SPECIFICATIONS:
Shall be a Southbend Model _____________________________,
convection steamer with electric steam boiler base, ASME code stamped
and National Board registered. The steamer shall be constructed of #4
nish stainless steel type 304, with a cooking chamber of one-piece, all
welded, 316 stainless steel and shall be:
ECX-2, 13.875” W x 10.875” H x 19.875” D (352 mm x 276 mm x 504 mm).
ECX-10, 13.875” W x 17.375” H x 19.875” D (352 mm x 441 mm x 504 mm).
The chamber shall be fully insulated and provided with removable
stainless steel pan supports. The doors shall have a removable inner
liner of stainless steel with full perimeter gasket seal, an outer shell of
one piece all welded stainless steel, a positive lock and seal mechanism
and a stainless steel drip trough connected to drain to collect condensate
when door is opened.
Steamer controls shall be accessible through a full removable side panel
and each compartment shall include a 60 minute mechanical timer with
ready pilot and cooking pilot light and shall interrupt steam ow to the
chamber when the door is opened during cooking cycle and shall be
reactivated when the door is closed. An audible signal which will sound
at the end of the cooking cycle.
The cabinet base with electric boiler and controls shall be provided
with full perimeter angled frame, reinforced boiler mountings, gas boiler
with controls, all stainless steel exterior, hinged door(s) with magnetic
latch and 6” (152 mm) stainless steel legs tted with adjustable bullet
feet on the front and adjustable anged feet on the rear for securing to
the oor. Standard boiler controls shall include automatic water level
control, pressure gauge, water gauge glass, operating pressure control
with pressure safety control, safety relief valve and cathodic protector.
ElEctric convEction StEamEr
on cabinEt baSE
Compartment pan CapaCity
model Standard Boiler
ECX-2 24 kW 6 3 2 1
ECX-10 36 kW 10 5 3 2
OPERATION SHALL BE BY:
Electrically heated steam boiler operating at 9 - 11 psi (62 - 76
kPa) and rated at:
24.0 kw (ECX-2 standard)
36.0 kw (ECX-10 standard)
. The steam boiler shall be equipped for operation on:
208 VAC, 3 Phase, 60 Hz
240 VAC, 3 Phase, 60 Hz
The controls shall be equipped for operation on 115 VAC, 1
Phase, 60 Hz
OPTIONAL ITEMS AT EXTRA COST:
36.0 kw
42.0 kw
48.0 kw (240 VAC min.)
220 VAC, 3 PHASE, 60 Hz
380 VAC, 3 PHASE, 60 Hz
415 VAC, 3 PHASE, 60 Hz
480 VAC, 3 PHASE, 60 Hz
600 VAC, 3 PHASE, 60 Hz
380/220 VAC, 3 PHASE, 60 Hz, 4 wire
415/240 VAC, 3 PHASE, 60 Hz, 4 wire
CSD-1
Automatic boiler blow down
36” wide cabinet
Stainless steel rear panel
Stainless steel frame
Split water line
Adjustable front anged feet
Load compensating timers
Cabinet size (48" or 60")
Correctional Package
ACCESSORIES:
Spray and rinse assembly
De-liming kit (DPA-1) not available with CSD-1
Water in “Y” strainer
Steam take-off kit (STOK)
1” 2-1/2” 4” 6”
pan depth
Job Item#
Form ECX Rev 1 (December/2010)
www.yatesgd.com www.yatesgraphicdesign.com
Printed in USA
Models:
READY COOKING
COOKINGREADY
ECX-2 ECX-10
model
ECX-2 550 lbs. [249 kg] 650 lbs. [255 kg]
ECX-10 575 lbs. [260 kg] 700 lbs. [317 kg]
Shipping Weight
(24” CaBinet)
Shipping Weight
(36” CaBinet)
minimum ClearanCe
SIDES
BACK
0
0
SERVICE CONNECTIONS
– ELECTRICAL CONNECTION: Rating to be as specied on data plate.
– COLD WATER: 3/8” (10 mm) O.D. tubing at 25-50 psi (170-345 kPa).
– DRAIN: 2” (51 mm) IPS piped to open oor drain. No solid connection.
– STEAM TAKE-OFF CONNECTION: 3/4” (19 mm) IPS optional to operate adjacent equipment.
ELECTRICAL CHARACTERISTICS
aVailaBle kW
model Standard optional
ECX-2 24 36, 42, 48
ECX-10 36 42, 48
kW phaSe 208V 220V 240V 380V 415V 480V
24 3 66.6 63.0 57.8 36.5 33.4 28.9
36 3 99.9 94.5 86.6 54.7 50.1 43.3
42 3 116.6 110.2 101.0 63.8 58.4 50.5
48 3 N/A N/A 115.5 72.9 66.8 57.7
ampS per line
WATER QUALITY STATEMENT
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a local water
treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Total dissolved solids ....................Less than 60 PPM
Total alkalinity ................................Less than 20 PPM
Silica ...............................................Less than 13 PPM
Chlorine .........................................Less than 30 PPM
pH Factor ......................................7.0 - 8.5
Water which fails to meet these standards should be treated by installation of water conditioner.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.
CONTACT SOUTHBEND FOR WATER QUALITY SOLUTIONS.
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.