SPECIFICATIONS:
Shall be a Model ECX-10 convection steamer with gas red steam boiler. The steamer shall be constructed of #4 nish
stainless steel type 304, with a cooking chamber of one piece all welded 316 stainless steel. The doors shall have a removable inner liner of stainless steel with full perimeter gasket seal, an outer shell of one piece all welded stainless steel, and a positive lock and seal mechanism. The door opening shall be 14” W x
17.25” (356 mm x 438 mm). The steamer shall be provided with removable stainless steel pan supports and a stainless steel drip trough connected to drain to collect condensate when door is opened.
Control housing shall be accessible through a full removable side panel. Controls shall include a 60 minute mechanical timer with ready pilot and cooking pilot light for each compartment and a audible signal which will sound at the end of the cooking
cycle. Steam ow to the chamber shall be interrupted when the
compartment door is opened during cooking cycle and shall be reactivated when the door is closed. The convection steamer shall be mounted on a cabinet base with full perimeter angle frame, reinforced counter and boiler mountings, gas boiler with controls, all stainless steel exterior, hinged door(s) with magnetic latch and 6” (152 mm) stainless steel legs tted with
adjustable bullet feet on the front and adjustable anged feet
on the rear. Standard boiler controls shall be automatic water level control, pressure gauge, water gauge glass, pressure control with pressure safety control, safety relief valve and cathodic protector.
El E c t r i c co n v E c t i o n St E a m E r
o n ca b i n E t ba S E
Co m p a r t m e n t pa n Ca p a C i t y
mo d e l
ECX-10 20 10 6 4
OPERATION SHALL BE BY:
Electrically heated steam boiler operating at 15 psi (103kPa) and rated at:
30.0 kw The steam boiler shall be equipped for operation on:
208 VAC, 3 Phase, 60 Hz 240 VAC, 3 Phase, 60 Hz
The controls shall be equipped for operation on 115 VAC, 1 Phase, 60 Hz
OPTIONAL ITEMS AT EXTRA COST:
Automatic boiler blow down 220 or 240 VAC, 1 Phase, 50 Hz Two water lines (boiler feed and condensate) De-lime piping assembly (DPA-1) Stainless steel frame Cabinet size (48" or 60") Stainless steel back on cabinet California State boiler code requirement CSD-1 220 VAC, 3 PHASE, 60 Hz 380 VAC, 3 PHASE, 60 Hz 480 VAC, 3 PHASE, 60 Hz Load compensate timer
ACCESSORIES:
Spray and rinse assembly 12" x 20" x 2.5" perforated stainless steel pan 12" x 20" x 2.5" solid stainless steel pan 12" x 20" x 4" perforated stainless steel pan 12" x 20" x 4" solid stainless steel pan Adjustable anged feet Ball oat trap Water in strainer Steam take-off kit
1” 2-1/2” 4” 6”
Job Item#
FormECX-10 Rev 0 (01/07)
www.yatesgd.com www.yatesgraphicdesign.com
Printed in USA
Models:
ECX-10S
SERVICE CONNCETIONS
– COLD WATER: 1/2” (13 mm).
– DRAIN: 2 required, 1” male pipe thread piped to open oor drain. No solid connection.
– ELECTRICAL CONNECTION: Single point supply 1-1/8” (29mm) dia. (3/4” conduit)
– COLD WATER: Generator: 3/8” (10mm) tubing at 25-50 PSI (170-345 kPa).
– COLD WATER: Condensing: 3/8” (10mm) tubing at 25-50 PSI (170-345 kPa).
UTILITIES
mo d e l ph a s e
ECX-10 3 30 99.9 30 94.5 30 86.6 30 54.7 30 43.3
Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:
Total dissolved solids ....................Less than 60 PPM
Total alkalinity ................................ Less than 20 PPM
Silica ...............................................Less than 13 PPM
Chlorine .........................................Less than 30 PPM
pH Factor ......................................7.0 - 8.5
208V 220V 240V 380V 480V
kW am p s kW am p s kW am p s kW am p s kW am p s
WATER QUALITY STATEMENT
Water which fails to meet these standards should be treated by installation of water conditioner.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY. WATER QUALITY STATEMENT
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.