SoundTube CM590i, CM801i, CM500i, CM800i Install Instructions Manual

Droptile Ceiling Install Instructions For:
CM590i, CM500i, CM800i & CM801i speakers
Strain relief (not included) may be used with cover plate .
Signal wire
Cover plate
Euroblock connector
1.435.647.9555
|
800.647.TUBE
|
www.soundtube.com
Ceiling thickness tolerances
Max
42.9 mm (1.69 in)
Cover plate clamping screw
Min
6.4 mm (0.25 in)
Seismic restraint anchor tab
Tile bridge
Ceiling tile
Box contents
1 Speaker 1 Euroblock connector 1 Grille and bezel 1 Styrofoam installation aid/paint mask 1 Cover plate 1 Tile bridge
Euroblock jack
Speed Wing™ mounting arms
Baffle
Styrofoam installation aid/paint mask
Grille and bezel seismic restraint
Grille and bezel
Transformer Taps Settings
CM500i
CM800i
CM801i
Voice Coil
8 Ohm=107 dB
8 Ohm=113 dB
4 Ohm=113 dB
70.7 Volt Transformer Taps (dB) 100 Volt Transformer Taps (dB) 25 Volt Transformer Taps (dB)
33W=102, 17W=99, 9W=96, 6W=93, 3W=90
66W=110, 35W=107, 19W=104, 10W=101, 5W=98
66W=110, 35W=107, 19W=104, 10W=101, 5W=98
Warning Warning
SoundTube speakers must be installed by a professional audio installer/contractor. For safety and for optimum audio performance, installer must follow all directions issued by SoundTube Entertainment.
© 2005 SoundTube Entertainment, Inc. All rights reser ved. PN INS-CMI Rev 01.27.05
33W=102, 17W=99, 9W=96, 6W=93
66W=110, 35W=107, 19W=104, 10W=101
66W=110, 35W=107, 19W=104, 10W=101
Do not spec or install speaker near support beam, ventilation duct or other structure that may interfere with speaker function or dispersion.
3W=90, 1.5W=87, .75W=84, .38W=81
5W=98, 2.5W=95, 1.25W=92, .75W=89
5W=98, 2.5W=95, 1.25W=92, .75W=89
do not over-tighten.
Droptile Ceiling Install Instructions For:
CM590i, CM500i, CM800i & CM801i speakers
1.435.647.9555
|
800.647.TUBE
|
www.soundtube.com
1. Unpack speaker & set
aside grille assembly.
5. Insert speaker into mounting hole on ground with installation aid in place. Screw down both bolts on the baffle face to actuate the mounting wings. Firmly secure both bolts –
do not over-tighten.
Put
assembly into tile grid.
2. Keep Styrofoam installation aid/paint mask attached to speaker until speaker installation is complete.
6. Thread signal wire through
cover plate. Connect signal wire to 4-pin Euroblock plug. Tighten unused terminal screws. Use inside positive and negative inputs for either voice coil or distributed systems. For daisy chaining, use outside positive and negative terminals.
3. Use included tile bridge to mark cutout in tile.
7. Insert the Euroblock plug into the Euroblock jack on rear panel of speaker and replace cover plate.
For UL-compliant install ations strain relief (not supplied) may be inserted into hole in cover plate.
4. Use Rotozip or other tool
to cut hole.
Hole Diameters
CM500i
228.6 mm (9.00 in)
CM800i & CM801i
325.1 mm (12.80 in)
. If required, attach the seismic restraint system to the sheet-metal tab on the rear panel of the speaker (safety cable not included).
11. Select the tap position by adjusting rotary switch to desired high impedance value or voice coil bypass mode. Switch is preset to maximum tap setting in
70.7 V mode (33 W or 66 W).
SoundTube also provides optional Pre Construction Brackets & Architectural Grilles for the CMi product line.
Installation instructions for these accessories are included with specific accessory packaging.
12. Attach grille & bezel seismic restraint to baffle with provided screw.
13. Attach grille – position the grille over the baffle and allow magnets to attract grille into place. Be sure grille is properly centered over baffle.
Loading...
+ 2 hidden pages