Droptile Ceiling Install Instructions For:
CM590i, CM500i, CM800i & CM801i speakers
Strain relief (not included) may
be used with cover plate .
Signal wire
Cover plate
Euroblock connector
1.435.647.9555
|
800.647.TUBE
|
www.soundtube.com
Ceiling thickness tolerances
Max
42.9 mm (1.69 in)
Cover plate clamping screw
Min
6.4 mm (0.25 in)
Seismic restraint anchor tab
Tile bridge
Ceiling tile
Box contents
1 Speaker
1 Euroblock connector
1 Grille and bezel
1 Styrofoam installation aid/paint mask
1 Cover plate
1 Tile bridge
Euroblock jack
Speed Wing™ mounting arms
Baffle
Styrofoam installation aid/paint mask
Grille and bezel
seismic restraint
Grille and bezel
Transformer Taps Settings
CM500i
CM800i
CM801i
Voice Coil
8 Ohm=107 dB
8 Ohm=113 dB
4 Ohm=113 dB
70.7 Volt Transformer Taps (dB) 100 Volt Transformer Taps (dB) 25 Volt Transformer Taps (dB)
33W=102, 17W=99, 9W=96, 6W=93, 3W=90
66W=110, 35W=107, 19W=104, 10W=101, 5W=98
66W=110, 35W=107, 19W=104, 10W=101, 5W=98
Warning Warning
SoundTube speakers must be installed by a professional audio
installer/contractor. For safety and for optimum audio performance,
installer must follow all directions issued by SoundTube Entertainment.
© 2005 SoundTube Entertainment, Inc. All rights reser ved. PN INS-CMI Rev 01.27.05
33W=102, 17W=99, 9W=96, 6W=93
66W=110, 35W=107, 19W=104, 10W=101
66W=110, 35W=107, 19W=104, 10W=101
Do not spec or install speaker near support beam, ventilation
duct or other structure that may interfere with speaker function
or dispersion.
3W=90, 1.5W=87, .75W=84, .38W=81
5W=98, 2.5W=95, 1.25W=92, .75W=89
5W=98, 2.5W=95, 1.25W=92, .75W=89
Droptile Ceiling Install Instructions For:
CM590i, CM500i, CM800i & CM801i speakers
1.435.647.9555
|
800.647.TUBE
|
www.soundtube.com
1. Unpack speaker & set
aside grille assembly.
5. Insert speaker into
mounting hole on ground
with installation aid in
place. Screw down both
bolts on the baffle face to
actuate the mounting wings.
Firmly secure both bolts –
do not over-tighten.
Put
assembly into tile grid.
2. Keep Styrofoam
installation aid/paint
mask attached to
speaker until speaker
installation is complete.
6. Thread signal wire through
cover plate. Connect signal
wire to 4-pin Euroblock plug.
Tighten unused terminal
screws. Use inside positive
and negative inputs for either
voice coil or distributed
systems. For daisy chaining,
use outside positive and
negative terminals.
3. Use included tile bridge
to mark cutout in tile.
7. Insert the Euroblock plug
into the Euroblock jack on
rear panel of speaker and
replace cover plate.
For UL-compliant install
ations strain relief (not
supplied) may be inserted
into hole in cover plate.
4. Use Rotozip or other tool
to cut hole.
Hole Diameters
CM500i
228.6 mm (9.00 in)
CM800i & CM801i
325.1 mm (12.80 in)
. If required, attach the
seismic restraint system to
the sheet-metal tab on the
rear panel of the speaker
(safety cable not included).
11. Select the tap position
by adjusting rotary switch
to desired high impedance
value or voice coil bypass
mode. Switch is preset to
maximum tap setting in
70.7 V mode (33 W or 66 W).
SoundTube also provides optional Pre Construction Brackets & Architectural Grilles for the CMi product line.
Installation instructions for these accessories are included with specific accessory packaging.
12. Attach grille & bezel
seismic restraint to baffle
with provided screw.
13. Attach grille – position the
grille over the baffle and allow
magnets to attract grille into
place. Be sure grille is properly
centered over baffle.