Sound Performance Lab 2053 User Manual

24/96 AD-DA Converter
Manual
Model 2053
Manual
24/96 AD-DA Converter 2053
2
24/96 AD-DA Converter 2053
The information in this document has been carefully verified and is assumed to be correct. However Sound Performance Lab (SPL) reserves the right to modify the product described in this manual at any time. Changes without notice. This document is the property of SPL and may not be copied or reproduced in any manner, in part or full without the authorization of SPL.
Limitations of Liability:
In no event will SPL be liable for any damages, inclu­ding loss of data, lost profits, cost of cover or other special, incidental,consequential or indirect damages arising from the use of the unit, however caused and on any theory of liability.This limitation will apply even if SPL or an authorized dealer has been adviced of the possibility of such damage.
Sound Performance Lab P.O.Box 12 27 D- 41368 Niederkruechten, Germany Phone +49 - 21 63 / 98 34-0 Fax +49 - 21 63 / 98 34-20 eMail: info@soundperformancelab.com
www.soundperformancelab.com
© 2000 SPL electronics GmbH. All Rights Reserved.
Contents
3
24/96 AD-DA Converter 2053
Security Advices ................................................................ 4
Product Description ......................................................... 4
Mounting
General Information ................................................. 5
Steps 1 and 2 .............................................................. 6
Steps 3 and 4 .............................................................. 7
Connections ........................................................................ 8
Analog XLR Outputs ................................................ 8
Digital I/Os .................................................................. 9
Operation
Scope of Functions ................................................... 9
AD MODE Switch ...................................................... 10
ERROR-LEDs ............................................................... 10
External Synchronization ....................................... 11
Applications
Channel One: Using both converters .................. 12
Ch. One:Using both channels of the converter 12
24Bit/96 kHz Monitoring ........................................ 13
Analog processing of a digital signal ................. 13
Example 1: Processing a sampler’s signal .......... 14
Example 2: Recording on a DAT Recorder .......... 14
Specifications ..................................................................... 15
Block Diagram .................................................................... 16
Measurements ................................................................... 17
Warranty .............................................................................. 19
Security Advices
4
24/96 AD-DA Converter 2053
• Please consider referring the installation of the unit operating the converter the safety information in the corresponding operation instruction.
• Please carry out the self-installation only as descri­bed from page 5. In case of queries please contact an expert.
The SPL converter module 2053 combines separately useable A/D and D/A converters,with a wordwidth up to 24 Bits,and a Sample-rate of up to 96 kHz.
The D/A converter processes up to 24 Bits automati-
cally,as well as sample-rates from 32Bit to 96 kHz and is equipped with high-quality, balanced XLR outputs (+ 12 dBu).
The A/D converter supports 16 and 24Bit formats
and works. The reduction from 24Bit to 16Bit is processed with the Dithering-method: the "missing" lower 8Bit is not cut off,but rather "included" in the 16 Bit format. This ensures that quietest passages are preserved.
Internal Synchronization: The converter module
allows to choose 5 different clock sources via the AD MODE switch.The internal sample rates (96 kHz/48kHz and 88.2 kHz/44.1kHz) are Quartz-generated.
Product Description
5
24/96 AD-DA Converter 2053
External synchronization: For synchronization with external sources, AES-data or Word-Clock signals can be used as sync sources. Alternatively the A/D converter can be synchronized to the data adjacent to the D/A converter. For internal/external synchroniza­tion please refer to the chapter "Operation", from page 11.
The SPL converter module 2053 is exclusively offered as an option for certain SPL units.We especially advise electronically inexperienced users to contact an expert in case of queries.
• In order to avoid static loads, please deactivate the GND-Lift switch on the back of the unit that is to be upgraded and touch its case.
• Now pull the power cord out of the socket on the back of the unit operating the converter module. Please also remove all other cable connections.
• Treat the converter carefully. Please make sure that you only touch the front panel or the sides of the cir­cuit board in order to avoid contact with parts on the circuit board.Never force any parts when connecting unit and converter module.
Product Description
Mounting
General Information
Mounting
Steps 1 and 2
6
24/96 AD-DA Converter 2053
Step 1: Please put the converter module as illust-
rated on the unit top and remove the screws of the cover from the back of the upgrade unit.
Step 2: Please remove the mounting of the wiring on
the back of the cover (eventually cut off the silicon).
Socket
Socket
Connector
Loading...
+ 14 hidden pages