Sota MP5 Instructions Manual

Instructions for SOTA
Magnetic Pulser - Model MP5
WELCOME TO SOTA ................................................................................................ 2
BEFORE USING .......................................................................................................... 2
LEARN MORE ............................................................................................................ 2
COMPLETE UNIT INCLUDES ................................................................................. 2
DO NOT USE ............................................................................................................... 3
CAUTIONS .................................................................................................................. 3
SUMMARY OF LIGHTS ............................................................................................ 4
HOW TO USE THE MAGNETIC PULSER ............................................................. 4
How it Should Feel ................................................................................................. 5
Typical Use .............................................................................................................. 5
ELECTRICAL SPECIFICATIONS ............................................................................ 6
Power Requirements .............................................................................................. 6
Optional Power Input ............................................................................................ 6
Output Specications............................................................................................. 6
TROUBLESHOOTING ............................................................................................... 6
COUNTRIES THAT PARTICIPATE IN MANUFACTURING ............................ 7
REPLACEMENT ACCESSORIES ............................................................................. 7
WARRANTY................................................................................................................ 7
REPAIRS ....................................................................................................................... 7
• The SOTA units are consumer products designed to be used as part of a Wellness Lifestyle • The SOTA units are not medical devices nor are they intended to diagnose, treat or cure any medical or health condition • The use, safety or effectiveness of the SOTA units, has not been approved by any government agency • Please consult a health practitioner for any medical or health condition. • Results using the SOTA Products will vary for each person. • Please note that all purchases of SOTA Products are deemed to be made in Penticton, BC, Canada •
© 2010 SOTA Instruments Inc. Page 1 of 7 www.sota.com
Instructions for the SOTA Magnetic Pulser, Model MP5
WELCOME TO SOTA
Thank you for allowing us to be a part of your wellness team.
The Magnetic Pulser is a consumer product designed to be used as part of a Wellness Lifestyle. A commitment to healthy lifestyle choices is an important factor in the journey to Wellness.
The SOTA Magnetic Pulser offers the benets of a pulsed magnetic eld to help
balance the body’s natural electricity for health.
The Magnetic Pulser is designed to be used independently, but can also be used together with any of the SOTA Products.
With proper care, your Magnetic Pulser should provide you many years of trouble­free use.
Please understand that results will vary.
BEFORE USING
Please read this manual thoroughly before using your Magnetic Pulser.
Please note information in this manual is subject to change.
For the most up-to-date manual, please visit our website www.sota.com.
LEARN MORE
To learn more about the Magnetic Pulser we invite you to visit the SOTA website:
www.sota.com
The website offers How to Videos, Frequently Asked Questions, An Overview to Using the SOTA Units, SOTA News ... and more.
COMPLETE UNIT INCLUDES
One (1) Magnetic Pulser Unit
One (1) Wall Adaptor
One (1) Carrying Case
One (1) Product Manual
• The SOTA units are consumer products designed to be used as part of a Wellness Lifestyle • The SOTA units are not medical devices nor are they intended to diagnose, treat or cure any medical or health condition • The use, safety or effectiveness of the SOTA units, has not been approved by any government agency • Please consult a health practitioner for any medical or health condition. • Results using the SOTA Products will vary for each person. • Please note that all purchases of SOTA Products are deemed to be made in Penticton, BC, Canada •
© 2010 SOTA Instruments Inc. Page 2 of 7 www.sota.com
Instructions for the SOTA Magnetic Pulser, Model MP5
DO NOT USE
1. Do not use in the following situations as safety has not been explored:
a. In the case of pregnancy, nursing or trying to get pregnant.
b. With an implanted device such as a pacemaker, shunt etc.
c. In the area of a metal implant. Metal dental llings may also be affected.
Some metals absorb the heat generated by the magnetic eld and can cause
discomfort or a burn.
d. With neuropathy or other nerve-ending related issues.
e. On external or internal bleeding wounds, including menstruation, as Pulsed
Magnetic Fields increase blood ow.
f. With heat-producing or heat-sensitive ointments, lotions or medications as a
skin burn may occur.
2. As with all electrical products do not use:
a. Near water
b. When driving a car
c. When operating heavy equipment
CAUTIONS
1. It is possible that using Pulsed Magnetic Fields can mask pain. It is wise to consult a health practitioner to determine the cause of the pain.
2. While the science is inconclusive, the South (+) polarity may stimulate. For this reason, we suggest caution if applying the South (+) polarity side of the Hand Paddle to any condition where stimulation may be harmful or undesirable. The South (+) side of the Hand Paddle is the side with the SOTA logo.
3. With normal use, the Hand Paddle will become very warm to hot. If it feels uncomfortable, turn the unit off and allow it to cool before resuming use to prevent burning yourself.
4. To prevent damage or loss of information, keep away from homeopathic remedies, credit cards, security cards, audio and video tapes. Also from electronic equipment—computer disks, hearing aids, cell phones, answering machines and others.
• The SOTA units are consumer products designed to be used as part of a Wellness Lifestyle • The SOTA units are not medical devices nor are they intended to diagnose, treat or cure any medical or health condition • The use, safety or effectiveness of the SOTA units, has not been approved by any government agency • Please consult a health practitioner for any medical or health condition. • Results using the SOTA Products will vary for each person. • Please note that all purchases of SOTA Products are deemed to be made in Penticton, BC, Canada •
© 2010 SOTA Instruments Inc. Page 3 of 7 www.sota.com
Instructions for the SOTA Magnetic Pulser, Model MP5
5. While this technology is generally considered safe, there exists potential for rare individual reactions that cannot reasonably be foreseen. Therefore, your use of the SOTA Products constitutes your agreement that you are responsible for your decision to use the technology.
SUMMARY OF LIGHTS:
GREEN: Indicates the unit is on and the pulse is building.
RED: Indicates the pulse is being released.
YELLOW: Indicates the Sound option is on.
HOW TO USE THE MAGNETIC PULSER
1. Insert the power plug from the AC-DC wall adaptor into the unit and plug the adaptor into an electrical outlet.
2. Push the ON/OFF button. All the lights will ash in sequence to indicate the unit is ready for use.
green lights indicate the pulse is building. The red
The
light will ash each time the Pulsed Magnetic Field is
released from the Hand Paddle. A click may or may not be heard as the pulse is released.
3. Sound option: To hear a beep each time the pulsed eld is released, push the SOUND button. The yellow light will indicate the audio option is ON.
4. The head of the Hand Paddle should be located on or as close to the body as possible. It does not need to touch the body. Clothing will not interfere with the
magnetic eld.
Note: The Pulsed Magnetic Field penetrates up to nine inches.
5. For most applications, use the side of the Hand Paddle marked Bio-North (-) against the body.
6. When a cycle nishes (approx. 20 - 30 minutes) the unit will beep. To continue with another cycle, push the ON/OFF button
• The SOTA units are consumer products designed to be used as part of a Wellness Lifestyle • The SOTA units are not medical devices nor are they intended to diagnose, treat or cure any medical or health condition • The use, safety or effectiveness of the SOTA units, has not been approved by any government agency • Please consult a health practitioner for any medical or health condition. • Results using the SOTA Products will vary for each person. • Please note that all purchases of SOTA Products are deemed to be made in Penticton, BC, Canada •
© 2010 SOTA Instruments Inc. Page 4 of 7 www.sota.com
Instructions for the SOTA Magnetic Pulser, Model MP5
within 20 seconds of the beep. The unit turns itself off
if the ON/OFF button is not pushed within this time.
7. To turn the unit off before the end of a cycle, push the ON/OFF button.
8. Unplug the wall adaptor when not in use.
HOW IT SHOULD FEEL
Most individuals will not feel any sensation while using the Magnetic Pulser.
With normal use, the Hand Paddle will become very warm to hot. If it feels uncomfortable, turn the unit off and allow it to cool before continuing. Another option is to place a towel or another layer of clothing under the Hand Paddle.
TYPICAL USE
Length of session: It is best to begin slowly (10 minutes) and then gradually
increase the length of each session. Daily use
varies from 20 - 30 minutes to two hours or
more.
Length of use: When used as part of a wellness protocol, daily use for many weeks is more important for results than using occasionally.
For specic purposes, longer and more frequent sessions may be more benecial. Generally, the
Magnetic Pulser can be used as needed.
Placement: The Hand Paddle may be kept on one location for one or more cycles. It may also be moved at any time to a different location.
Drink plenty of water: It’s important to drink enough water when using the unit. Drinking ozonated water is especially helpful.
Stop Gradually: Reduce the amount of time each day for the last week of use. If using more than one SOTA unit at a time, it is suggested to stop only one unit at a time.
• The SOTA units are consumer products designed to be used as part of a Wellness Lifestyle • The SOTA units are not medical devices nor are they intended to diagnose, treat or cure any medical or health condition • The use, safety or effectiveness of the SOTA units, has not been approved by any government agency • Please consult a health practitioner for any medical or health condition. • Results using the SOTA Products will vary for each person. • Please note that all purchases of SOTA Products are deemed to be made in Penticton, BC, Canada •
© 2010 SOTA Instruments Inc. Page 5 of 7 www.sota.com
Instructions for the SOTA Magnetic Pulser, Model MP5
ELECTRICAL SPECIFICATIONS
Your Magnetic Pulser outputs a time-variant pulsed DC magnetic eld.
POWER REQUIREMENTS
12 Volts DC @ 1.5 Amps, Tip or Center Positive.
Caution: Exceeding the voltage rating or reverse connection may result in injury or unit failure. This will void the warranty.
OPTIONAL POWER INPUT
To operate the Magnetic Pulser from a 12 Volt DC source, such as an automobile battery or an appropriate Solar Panel, purchase a Universal Power Cord with Tip or Center Positive.
OUTPUT SPECIFICATIONS
Magnetic Field Intensity: Greater than 6,000 Gauss at face of the Hand Paddle as tested with an F.W.Bell 5080 Tesla Meter.
Pulse Duration: ~2.5 mS (milliseconds).
Pulses per Cycle: 255 pulses (approx. 20 - 30 minutes).
TROUBLESHOOTING
If there is no power to the unit, please check the following:
1. Ensure the wall adaptor is fully plugged into the wall socket.
2. Ensure the power plug from the wall adaptor is inserted fully into the unit.
3. Try another wall adaptor if available.
Note: An alternate wall adaptor must meet the specications described in Power
Requirements on page 6.
If the lights ash rapidly and the unit turns itself off, there may be a problem. Press
the ON button to check if the unit will operate normally or if there is a problem with the unit.
If a problem still exists, see the Repairs section on page 7.
For further Troubleshooting, visit www.sota.com.
• The SOTA units are consumer products designed to be used as part of a Wellness Lifestyle • The SOTA units are not medical devices nor are they intended to diagnose, treat or cure any medical or health condition • The use, safety or effectiveness of the SOTA units, has not been approved by any government agency • Please consult a health practitioner for any medical or health condition. • Results using the SOTA Products will vary for each person. • Please note that all purchases of SOTA Products are deemed to be made in Penticton, BC, Canada •
© 2010 SOTA Instruments Inc. Page 6 of 7 www.sota.com
Instructions for the SOTA Magnetic Pulser, Model MP5
COUNTRIES THAT PARTICIPATE IN MANUFACTURING
The manufacturing of the SOTA Products is a global collaboration. The following countries participate in the making of the Magnetic Pulser (listed in alphabetical order): Canada, China, Hong Kong, Malaysia, Mexico, Taiwan, Thailand and the USA.
REPLACEMENT ACCESSORIES
To replace your accessories, please contact your supplier.
WARRANTY
The Magnetic Pulser, MP5 is covered by a two (2) year limited warranty. Please keep proof of purchase. Warranty is void if the failure is due to abuse or negligence.
REPAIRS
Please contact your supplier for return instructions. Or, for information about your closest repair depot, contact repairs@sota.com or
Toll-Free: 1.800.224.0242 (Canada & USA) Tel: 1.250.770.2023 Fax: 1.250.770.1999
Made in China and Designed and Engineered in Canada.
• The SOTA units are consumer products designed to be used as part of a Wellness Lifestyle • The SOTA units are not medical devices nor are they intended to diagnose, treat or cure any medical or health condition • The use, safety or effectiveness of the SOTA units, has not been approved by any government agency • Please consult a health practitioner for any medical or health condition. • Results using the SOTA Products will vary for each person. • Please note that all purchases of SOTA Products are deemed to be made in Penticton, BC, Canada •
© 2010 SOTA Instruments Inc. Page 7 of 7 www.sota.com
Loading...