1286-9338 Rev 3
Sony Mobile Communications AB – Company Internal

1286-9338 Rev 3
Sony Mobile Communications AB – Company Internal
Test and Calibration Repair Instruction
CONTENTS
Go/No Go Testing ................................................................................. 3
1.1 Antenna Coupler L50t and L50u no LTE ............................................. 3
1.2 Antenna Coupler L50t L50u no TD-SCDMA ........................................ 3
The following equipment has to be used: .................................................. 3
1.3 Attenuation Factors ............................................................................. 5
1.3.1 Loss Values – Antenna Coupler CMU-Z11 ................................................ 5
1.3.2 Loss Values – Antenna Coupler CMW-Z11 ................................................ 6
2 Revision History ............................................................................. 8
L50t no TD-SCDMA, no LTE bands is implemented in SERPII.
L50t only TD-SCDMA bands is implemented in Sony Lector.
L50t & L50u no TD-SCDMA is implemented in CMWrun.
L50u no LTE bands is implemented in SERPII.

1286-9338 Rev 3
Sony Mobile Communications AB – Company Internal
For more information on Antenna Coupler and Cable in shield box testing, refer to
1220-1336: Generic Repair Manual – electrical, section ‘Setup Go/NoGo Test’!
For part no’s on the equipment below, refer to the ‘Tools Catalogue/Matrix’!
1.1 Antenna Coupler L50t and L50u
no LTE
The following equipment has to be used:
Rohde & Schwartz RF Shield Package
- Rohde & Schwartz RF Shield Box CMU-Z11
- Rohde & Schwartz RF Coupler
- Grid Positioning Holder
RF Test Cable Flexible 1M
RF Adapter for RF Shield Box
Micro USIM Card, instrument specific
GSM-850/900/1800/1900
WCDMA-850/900/1700/1900/2100
TD-SCDMA-BAND 34/39
Put the grid positioning holder with its reference point in
position F11 and place the phone as shown in the adjacent
picture.
A FEDB C G H I NMLJ K O P Q R
25
15
16
17
18
19
20
21
22
23
24
14
4
5
6
7
8
9
10
11
12
13
1
2
3
A FEDB C G H I NMLJ K O P Q R
25
15
16
17
18
19
20
21
22
23
24
14
4
5
6
7
8
9
10
11
12
13
1
2
3
1.2 Antenna Coupler L50t
L50u no TD-SCDMA
The following equipment has to be used:
Rohde & Schwartz RF Shield Package
- Rohde & Schwartz RF Shield Box
- Rohde & Schwartz RF Coupler CMW-Z11
- Grid Positioning Holder
RF Test Cable Flexible 1M
RF Adapter for RF Shield Box
Micro USIM Card, instrument specific
GSM-850/900/1800/1900
WCDMA-850/900/1900/2100
LTE-BAND 1/3/7/38/39/40/41
Put the grid positioning holder with its reference point in
position i13 and place the phone as shown in the adjacent
picture.
Go/No Go Testing
This Go/No Go testing has to be carried out with an:
Antenna Coupler.
Test and Calibration Repair Instruction