Sony VAIO PCGA-PRF1 Service Manual

PCGA-PRF1 (UC/AEP/UK)
PCGA-PRF1
US Model
PCGA-PRF1 (UC/AEP/UK)
Connectors SERIAL Connector,RS-232C, D-
Specifications
SUB 9 pin (1) PRINTER Connector, ECP, D­SUB 25 pin (1) MONITOR Connector, analog RGB, mini D-SUB 15 pin (1) USB Connector, USB 4 pin (1) NETWORK Connector, 10BASE-T (1) MOUSE/KEYBOARD Connector,PS/2, mini DIN 6 pin (2)
Canadian Model
AEP Model
Operating temperature
Dimensions Approx. 127/8× 111/16× 43/
Mass 470 g (14.3 oz.) Supplied accessory
Design and specifications are subject to change without notice.
41°Fto95°F(5°Cto35°C)
inches (w/h/d)
ox.
(Appr 324 × 42 × 109 mm)
Operating instructions (1)
8
UK Model
9-974-497-11
Sony Corporation
xxx
– 24 –
English
99x16xx-1
Printed in xxx
© 1999. x
xxx
99x16xx-1
Port Replicator
9-974-497-11
Information in this document is subject to change without notice.
Sony and VAIO are trademarks of Sony. Intel logo and Intel Inside logo are registered trademarks of Intel Corporation. Pentium MMX is a trademark of Intel Corporation. Microsoft, MS-DOS, Windows, the Windows 95 and Windows 98 logo are trademarks of Microsoft Corporation.
Caution Markings for Lithium/Ion Battery - The following or similar texts shall be provided on battery pack of equipment or in both the operating and the service instructions.
CAUTION: Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer’s instructions.
All other trademarks are trademarks or registered trademarks of their respective owners. Other trademarks and trade names may be used in this document to refer to the entitles claiming the marks and names or their produces. Sony Corporation disclaims any proprietary interest in trademarks and trade names other than its own.
Service and Inspection Precautions
1. Obey precautionary markings and instructions
Labels and stamps on the cabinet, chassis, and components identify areas requiring special precautions. Be sure to observe these precautions, as well as all precautions listed in the operating manual and other associated documents.
2. Use designated parts only
The set’s components possess important safety characteristics, such as noncombustibility and the ability to tolerate large voltages. Be sure that replacement parts possess the same safety characteristics as the originals. Also remember that the ! mark, which appears in circuit diagrams and parts lists, denotes components that have particularly important safety functions; be extra sure to use only the designated components.
CAUTION: The battery pack used in this device may present a fire or chemical burn hazard if mistreated. Do not disassemble, heat above 100°C (212°F) or incinerate. Dispose of used battery promptly. Keep away from children.
4. Inspect after completing service
After servicing, inspect to make sure that all screws, components, and wiring have been returned to their original condition. Also check the area around the repair location to ensure that repair work has caused no damage, and confirm safety.
5. When replacing chip components...
Never reuse components. Also remember that the negative side of tantalum capacitors is easily damaged by heat.
6. When handling flexible print boards...
•The temperature of the soldering-iron tip should be about 270C.
•Do not apply the tip more than three times to the same pattern.
•Handle patterns with care; never apply force.
3. Always follow the original design when mounting parts and routing wires
The original layout includes various safety features, such as inclusion of insulating materials (tubes and tape) and the mounting of parts above the printer board. In addition, internal wiring has been routed and clamped so as to keep it away from hot or high-voltage parts. When mounting parts or routing wires, therefore, be sure to duplicate the original layout.
PCGA-PRF1 (UC/AEP/UK)
Caution: Remember that hard disk drives are easily damaged by vibration. Always handle with care.
ATTENTION AU COMPOSANT AYANT RAPPORT
À LA SÉCURITÉ! LES COMPOSANTS IDENTIFÉS P AR UNE MARQUE ! SUR LES DIAGRAMMES SCHÉMA TIQUES ET LA LISTE DES PIÈCES SONT CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE REMPLACER CES COMPOSANTS QUE PAR DES PIÈSES SONY DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU DANS LES SUPPÉMENTS PUBLIÉS PAR SONY.
– 2 –

TABLE OF CONTENTS

Section Title Page
CHAPTER 1. OPERATION
1-1. Operating Instructions ..................................................... 1-1
(to 1-3)
CHAPTER 2. REMOVAL
2-1. Flowchart ......................................................................... 2-1
2-2. Assy Bottom .................................................................... 2-1
2-3. CNX-61 Board, Panel, CONN APR ................................ 2-2
(to 2-2)
CHAPTER 3. SELF DIAGNOSTICS
3-1. Required Tools and Peripheral Devices ........................... 3-1
3-2. Tools and Peripheral Device Connection......................... 3-3
3-3. How to Start the Disk-Based Diagnostics........................ 3-4
(to 3-4)
CHAPTER 4. BLOCK DIAGRAM......................... 4-1
(to 4-2)
CHAPTER 5. EXPLODED VIEWS AND
PARTS LIST ................................... 5-1
• Abbreviations UC : US model / Canadian model
(to 5-2)
– 3 – PCGA-PRF1 (UC/AEP/UK)
CHAPTER 1.
OPERATION

1-1. Operating Instructions

English
Port Replicator
Operating Instructions
Warning
To prevent fire or shock hazard, do not expose the unit to rain or moisture.
To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only.
Owner’s Record
The model number and serial number are located on the bottom of your port replicator. Record the serial number in the space providedhere. Refer to the model and serial number when you call your Sony Service Center.
Model No. PCGA-PRF1 Serial No. ___________________
PCGA-PRF1
(Extracted from 3-865-988-01 (1))
Specifications
Connectors SERIAL Connector, RS-232C, D-
Operating temperature
Dimensions Approx. 12
Mass 470 g (14.3 oz.) Supplied accessory
Design and specifications are subject to change without notice.
SUB 9 pin (1) PRINTER Connector, ECP, D­SUB 25 pin (1) MONITOR Connector,analog RGB, mini D-SUB 15 pin (1) USB Connector, USB 4 pin (1) NETWORK Connector, 10BASE-T (1) MOUSE/KEYBOARD Connector,PS/2, mini DIN 6 pin (2)
41°Fto95°F(5°Cto35 C)
inches (w/h/d) (Approx. 324 × 42 × 109 mm)
Operating instructions (1)
7
/8× 111/16× 43/
°
8
This product conforms with the following European Directives:
73/23/EEC (Low Voltage Directive) 89/336/EEC, 92/31/EEC (EMC Directive) 93/68/EEC (CE-Marking Directive)
This equipment complies with EN55022 Class B and EN50082-1 for use in the following areas: residential, business, and light-industrial.
This equipment has been tested and found to comply with the limits set out in the EMC Directive using a connection cable shorter than 3 meters (9.8 feet).
Before use
Before using the port replicator, please read this manual thoroughly and retain it for future reference. See also the VAIO Notebook Computer User Guide for more information. The Sony PCGA-PRF1 is the port replicator designed for a Sony Notebook Computer PCG­F100 series. It cannot be used with any other computer.
Notes on use
• Do not place the unit in locations that are: – Extremely hot or cold – Dusty or dirty – Very humid – Vibrating – Subject to strong magnetic fields – Sandy – Subject to direct sunlight
• Do not apply mechanical shock or drop the unit.
• Be sure that nothing metallic comes into contact with the metal parts of this unit. If this happens, a short-circuit may occur and the unit may be damaged.
• Do not operate the unit with a damaged cord or if it has been dropped or damaged.
• Always keep the metal contacts clean.
• Do not disassemble or convert the unit.
• While the unit is in use, it gets warm; this is normal.
• Keep the unit away from TV or AM receivers, because it can disturb TV or AM reception.
On cleaning
Clean the unit with a soft dry cloth, or a soft cloth lightly moistened with a mild detergent solution. Do not use any type of solvent, such as alcohol or benzine, which may damage the finish.
1-1 PCGA-PRF1 (UC/AEP/UK)
Français
PCGA-PRF1
Port Replicator
Mode d’emploi
Avertissement
Pour prévenir tout risque d’incendie ou d’électrocution, garder cet appareil à l’abri de la pluie et de l’humidité.
Pour prévenir tout risque d’électrocution, ne pas ouvrir le boîtier. Confier l’entretien de cet appareil exclusivement au personnel qualifié.
Ce produit est conforme aux directives européennes suivantes:
73/23/CEE (Basse tension) 89/336/CEE, 92/31/CEE (Directives CEM) 93/68/CEE (Marquage CE)
Cet équipement est conforme aux normes EN55022 Classe B et EN50082-1, limitant l’emploi dans les environnements résidentiel, professionnel et industriel léger.
Cet appareil a été testé et déclaré conforme aux limites de la Directive EMC lors de l’utilisation d’un câble de liaison de moins de 3 mètres.
Spécifications
Connecteurs Série (SERIAL), RS-232C, D-
Température d’utilisation
Dimensions Approx. 324 × 42 × 109 mm
Masse Approx. 470g (14.3 li.) Accessoire fourni
La conception et les spécifications sont sujettes à modifications sans préavis.
SUBà9broches (1) Imprimante (PRINTER), ECP, D-SUB à 25 broches (1) Moniteur (MONITOR), RVB analogique, miniconnecteur D­SUB à 15 broches (1) USB, USBà4broches (1) Réseau (NETWORK), 10BASE-T (1) Souris/Clavier (MOUSE/ KEYBOARD), PS/2, miniconnecteur DIN à 6 broches (2)
à
5 °C35°C (41 °Fà95°F)
(l/h/p) (Approx. 12 po.)
Mode d’emploi (1)
7
/8× 111/16× 43/
Remarques sur l’utilisation
8
Avant utilisation
Avantd’utiliser cet réplicateur de port, lisez attentivement le présent mode d’emploi et conservez-le pour toute référence ultérieure. Consultez également le Manual d’utilisation de ordinateur bloc-notes VAIO. Le PCGA-PRF1 Sony est le réplicateur de port conçu pour un ordinateur bloc-notes Sony série PCG-F100. Il ne peut être utilisé avec un autre ordinateur.
• Ne placez pas l’appareil dans des endroits : – extrêmement chauds ou froids; – poussiéreux ou sales; – très humides; – soumis à des vibrations; – soumis à de puissants champs
magnétiques; – sablonneux; – exposés au rayonnement direct du soleil.
• Ne soumettez pas l’appareil à des chocs mécaniques et ne le laissez pas tomber.
• Veillez à ce qu’aucun objet métallique n’entre en contact avec les parties métalliques de cet appareil. Si cela se produit, un court-circuit risque de survenir et d’endommager l’appareil.
• Ne faites pas fonctionner l’appareil avec un câble endommagé ou s’il est tombé et a subi des dommages.
• Veillez à ce que les contacts métalliques restent toujours propres.
• Ne démontez pas et ne transformez pas l’appareil.
• Le système chauffe en cours d’utilisation. C’est normal.
• Gardez l’appareil à l’écart des téléviseurs et des récepteurs AM, il peut causer des interférences dans la réception télévisée ou radiophonique.
Entretien
Nettoyez l’appareil au moyen d’un chiffon sec et doux, ou légèrement imprégné d’une solution détergente neutre. N’utilisez aucun type de solvant, comme de l’alcool ou de la benzine, qui risquerait de ternir le fini de l’appareil.
1-2PCGA-PRF1 (UC/AEP/UK)
Loading...
+ 9 hidden pages