Frequency range87.5–108 MHz
Antenna terminals75 ohms, unbalanced
Intermediate frequency10.7 MHz
Sensitivityat 50 dB quieting (mono) 22.1 dBf, 7µV/75Ω
(stereo) 42.1dBf, 7µV/75Ω
Usable sensitivity (IHF) 19.5 dBf, 5µV/75Ω
at 75 kHz deviation
S/N80 dB (mono), 75 dB (stereo)
Harmonic distortionat 1 kHz
0.3% (mono), 0.5% (stereo)
Frequency response30 Hz–15 kHz
(+0.5/–2.0 dB)
Separation35 dB at 1 kHz
Selectivity55 dB at 400 kHz
Outputat 75 kHz deviation
775 mV, 4.7 kilohms
AM tuner section
Frequency rangeUS, Canadian model :
531–1,710 kHz (9 kHz)
530–1,710 kHz (10 kHz)
AEP, UK, German, Italian model :
522–1,611 kHz (9 kHz)
E, Singapore, Australian, Chinese, Malaysia,
Saudi Arabia model :
531–1,602 kHz (9 kHz)
530–1,710k Hz (10 kHz)
Intermediate frequency450 kHz
Usable sensitivity(with AM loop antenna) AM : 500µV/m
Signal-to-noise ratio54 dB (500mV/m, 999 kHz)
Harmonic distortion0.5 % (50 mV/m, 400Hz)
Selectivity50 dB
US Model
Canadian Model
ST-JX661
AEP Model
UK Model
E Model
Austr alian Model
ST-JX661/SE200
Chinese Model
ST-SE200
General
Power requirementsUS, Canadian model :
120 V AC, 60 Hz
AEP, German, Italian model :
220-230 V AC, 50/60Hz
UK, Australian model :
240 V AC, 50/60Hz
E, Singapore, Chinese, Malaysia,
Saudi Arabia model :
110-120 V/220-240 V AC,
50/60 Hz adjustable
Power consumption7 W
Dimensions430 x 82 x 279 mm (w/h/d) (17 x
31/4 x 11 inches)
MassApprox. 2.4 kg (5 lb 4 oz)
Supplied accessoriseAudio cord (1)
AM loop antenna (1)
FM wire antenna (1)
Design and specifications are subject to change without notice.
5-1. Front Section..................................................................15
6. ELECTRICAL PARTS LIST ........................................17
MODEL IDENTIFICATION
– Model Number Label –
MODEL NO.
FM STEREO/FM-AM TUNER
ST-JX661
ST-SE200
SAFETY CHECK-OUT
After correcting the original service problem, perform the following
safety check before releasing the set to the customer :
Check the antenna terminals, metal trim, "metallized" knobs, screws,
and all other exposed metal parts for AC leakage. Check leakage as
described below.
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5mA (500 microampers).
Leakage current can be measured by any one of three methods.
1.A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers’ instructions to use these
instruments.
2.A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a V OM
or battery-operated A C voltmeter . The “limit” indication is 0.75V,
so analog meters must have an accurate low-voltage scale. The
Simpson 250 and Sanwa SH-63Trd are examples of a passive
VOM that is suitable. Nearly all battery operated digital
multimeters that have a 2V AC range are suitable. (See Fig. A)
To Exposed Metal
Parts on Set
US, Canadian model : AC 120⁄60Hz
UK, Australian model : AC 240⁄50Hz
AEP, German, Italian model : AC 220–230V⁄50Hz
E, Singapore, Chinese,
Malaysia, Saudi Arabia model : AC 110–120 V/220–240 V
⁄50/60 Hz
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK ! OR DOTTED LINE WITH
MARK ! ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS
LIST ARE CRITICAL TO SAFE OPERATION.
REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE
PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR IN
SUPPLEMENTS PUBLISHED BY SONY.
AC
µ
0.15 F
1.5k
Ω
Voltmeter
(0.75V)
Earth Ground
Fig. A. Using an AC voltmeter to check AC leakage.
ATTENTION AU COMPOSANT AYANT RAPPORT
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE ! SUR LES
DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES SONT
CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE
REMPLACER CES COMPOSANTS QUE PAR DES PIÈCES SONY
DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU
DANS LES SUPPLÉMENTS PUBLIÉS PAR SONY.
À LA SÉCURITÉ!
– 2 –
LOCATION OF CONTROLS
SECTION 1
GENERAL
12
1 POWER button
2 MEMORY SCAN button
3 STEREO/MONO button
4 Display window8 BAND button