– 4 –
CXA3095N
Electrical Characteristics See Electrical Characteristics Measurement Circuit (Ta = 25°C, VCC = 9V)
Item
Circuit current
Conversion
gain
∗1
Noise figure
∗1 ∗2
1% cross
modulation
∗1 ∗3
Max. output
power
Switch ON drift
∗4
+B supply
voltage drift
∗5
PLL OUT output
power
Band switch
voltage
IccV
IccU
CG1
CG2
CG3
CG4
NF1
NF2
NF3
NF4
CM1
CM2
CM3
CM4
Pomax
(sat)
∆fsw1
∆fsw2
∆fsw3
∆fsw4
∆fst1
∆fst2
∆fst3
∆fst4
PoscV
PoscU
VswV
VswU
VHF operation; no signal
UHF operation; no signal
VHF operation; fRF = 55MHz; Input level –40dBm
VHF operation; fRF = 360MHz; Input level –40dBm
UHF operation; fRF = 360MHz; Input level –40dBm
UHF operation; fRF = 800MHz; Input level –40dBm
VHF operation; fRF = 55MHz
VHF operation; fRF = 360MHz
UHF operation; fRF = 360MHz
UHF operation; fRF = 800MHz
VHF operation; fD = 55MHz, fUD = ±12MHz
VHF operation; fD = 360MHz, fUD = ±12MHz
UHF operation; fD = 360MHz, fUD = ±12MHz
UHF operation; fD = 800MHz, fUD = ±12MHz
50Ω load
VHF operation; fosc = 100MHz
VHF operation; fosc = 405MHz
UHF operation; fosc = 405MHz
UHF operation; fosc = 845MHz
VHF operation; fosc = 100MHz
VHF operation; fosc = 405MHz
UHF operation; fosc = 405MHz
UHF operation; fosc = 845MHz
VHF operation; 50Ω load
UHF operation; 50Ω load
VHF operation
UHF operation
38
37
17
18
23
23
99
97
91
89
+8
–20
–20
0
3
53
51
20
21
26
26
13
12
9
9
102
100
94
92
+10
–10
–10
63
62
23
24
29
29
16
15
13
13
±200
±300
±300
±300
±100
±200
±150
±150
0.5
10.5
mA
mA
dB
dB
dB
dB
dB
dB
dB
dB
dBµ
dBµ
dBµ
dBµ
dBm
kHz
kHz
kHz
kHz
kHz
kHz
kHz
kHz
dBm
dBm
V
V
Symbol Conditions Min. Typ. Max. Unit
∗1
Measured value for untuned inputs.
∗2
Noise figure is the direct-reading value of NF meter in DSB.
∗3
Desired signal (fD) input level is –33dBm. Undesired signal (fUD) is 100kHz, 30%AM at ±12MHz.
The measurement value is undesired signal level, it measured with a spectrum analyzer at S/I = 46dB.
∗4
Frequency variation form 3 seconds to 3 minutes after switch ON.
∗5
Frequency variation when Vcc = 9V ± 5% variation.