Sony CXA3085AN Datasheet

—1—
E97758-TE
Sony reserves the right to change products and specifications without prior notice. This information does not convey any license by any implication or otherwise under any patents or other right. Application circuits shown, if any, are typical examples illustrating the operation of the devices. Sony cannot assume responsibility for any problems arising out of the use of these circuits.
All Band TV Tuner IC with On-chip PLL
CXA3085AN
Supply voltage VCC1,VCC2 –0.3 to +5.5 V
VCC3 –0.3 to +10.0 V
Storage temperature Tstg –55 to +150 °C
Allowable power dissipation
PD 880 mW
(when mounted on a substrate)
Operating Conditions
Supply voltage VCC1, VCC2 4.75 to 5.3 V
VCC3 4.75 to 9.45 V
Operating temperature Topr –20 to +75 °C
Description
The CXA3085AN is a monolithic TV tuner IC which integrates local oscillator and mixer circuits for VHF band, local oscillator and mixer circuits for UHF band, an IF amplifier and a tuning PLL onto a single chip, enabling further miniaturization of the tuner.
Features
Low noise figure
Low power consumption (5 V, 54 mA typ.)
On-chip tuning PLL (3-wire bus format)
Selection of frequency steps 31.25 kHz, 50 kHz
and 62.5 kHz
On-chip 4-output band switch
SSOP 30-pin package
Applications
TV tuners
VCR tuners
CATV tuners
Structure
Bipolar silicon monolithic IC
30 pin SSOP (Plastic)
Note) Electrostatic discharge strength is weak, and care should be taken in handling this IC.
For the availability of this product, please contact the sales office.
—2—
CXA3085AN
Block Diagram and Pin Configuration
Input
Buffer
Bias
USW
IF AMP
CL DA CE
FMT
BVL
BVH
BU
VCC1
MIXout1
MIXout2
GND1
BYP
VHFin
UHFin1 UHFin2
Shift Register
Band SW Driver
V.REG
VHF
MIX
UHF
MIX
Buffer
VHF
OSC
UHF OSC
Buffer
Buffer
Phase Detector
Charge Pump
LOCK Det
Divider 14/15bit
Prescaler 1/8
REF OSC
Divider 1/512,640,1024
1 2
3
4
5
6
7
8
9
10 11
12
13
14 15
VOSC1
GND
VOSC2
UOSC1
MS
UOSC2
V
CC2
GND2
CPE
V
CC3
CPO
REFOSC
NC
IF OUT
LOCK
16
17
18
20
21
22
23
24
25
26
27
28
29
19
30
—3—
CXA3085AN
Pin Description
Pin
Symbol Equivalent circuit
Pin voltage
Description
No. (V)
1
2
3
4
5
6
7 8
9
10
11
CL
DA
CE
FMT
BVL
BVH
BU
VCC1
MIXout1
MIXout2
GND1
1.25
(when open)
ON : 4.9
OFF : 0
Clock input.
Data input.
Enable pin.
4 : Output for FM TRAP. 5 : Power supply output for
VL band.
6 : Power supply pin for VH
band.
7 : Power supply output for
UHF band.
The selected band pin goes High.
Analog circuit power supply.
Mixer outputs.
Analog circuit GND.
5k
100k
1
22
VCC2
5k
100k
2
22
VCC2
3
150k
50k
VCC2
22
20k
VCC3
4 5
6 7
30
9
10
—4—
CXA3085AN
Pin
Symbol Equivalent circuit
Pin voltage
Description
No. (V)
12
13
14
15
16
18
17
19
21
20
BYP
VHFin
UHFin1
UHFin2
VOSC1
VOSC2
GND
UOSC1
UOSC2
MS
2.5
(when open)
2.3
(VHF)
0
(UHF)
0
(VHF)
2.3
(UHF)
0
(VHF)
2.3
(UHF)
3
(VHF)
3.1
(UHF)
4.0
(VHF)
5.0
(UHF)
3.2
(VHF)
2.9
(UHF)
3.2
(VHF)
2.9
(UHF)
1.5
(when open)
VHF input GND and FMT/BU data switching.
VHF input. The input format is unbalanced input.
UHF inputs. The input method can be selected from balanced input or unbalanced input.
External resonance circuit connection for VHF oscillator.
GND
External resonance circuit connection for UHF oscillator.
Frequency step mode selection. Five modes can be selected according to the applied voltage.
20k
80k
VCC2
80k
1213
3k3k
14
15
50
VCC1
50k
18 16
8
15p
8p
3k
3k
VCC1
3k
19 21
3k
VCC2
20
120k
50k
22
—5—
CXA3085AN
Pin
Symbol Equivalent circuit
Pin voltage
Description
No. (V)
22 23 24
25
26
27
28
29
30
VCC2
GND2
NC
IFOUT
LOCK
CPE
CPO
REFOSC
VCC3
— — —
2.3
5.0
(Lock)
0.2
(UNLock)
0.6
2.0
4.3
PLL circuit power supply. PLL circuit GND. No connected.
IF output.
LOCK detection. High when locked, Low when unlocked.
NPN transistor connection for varicap diode drive.
Charge pump output. Connect a loop filter.
Crystal connection for reference oscillator.
Power supply for external supply.
VCC1
25
40
8
26
VCC2
22
40k
28
20k
500
27
22
200
VCC2
60k
29
30p
30p
— — —
—6—
CXA3085AN
Electrical Characteristics See the Electrical Characteristics Measurement Circuit. Circuit Current (VCC=5 V, Ta=25 °C)
Item
Circuit current A
Circuit current D
Symbol AICCV AICCU
DICC
Measurement conditions VCC1 current, Band switch output open during VHF operation VCC1 current, Band switch output open during UHF operation VCC2 current
Min. Typ. Max. Unit
30 41 55 mA
31 42 56 mA
7 11 15 mA
Item
Conversion gain
1
Noise figure ∗1,
2
1 % cross modulation ∗1,
3
Maximum output power
Switch ON drift
4
Supply voltage drift
4
Symbol CG1 CG2 CG3 CG4 NF1 NF2 NF3 NF4
CM1
CM2
CM3
CM4 Pomax
fsw1
fsw2
fsw3
fsw4
fst1
fst2
fst3
fst4
Measurement conditions VHF operation fRF = 55 MHz VHF operation fRF = 360 MHz UHF operation fRF = 360 MHz UHF operation fRF = 800 MHz VHF operation fRF = 55 MHz VHF operation fRF = 360 MHz UHF operation fRF = 360 MHz UHF operation fRF = 800 MHz VHF operation fD = 55 MHz, fUD = ±12 MHz VHF operation fD = 360 MHz, fUD = ±12 MHz UHF operation fD = 360 MHz, fUD = ±12 MHz UHF operation fD = 800 MHz, fUD = ±12 MHz 50 load saturation output VHF operation fOSC = 100 MHz f from 3 s to 3 min after switch ON VHF operation fOSC = 405 MHz f from 3 s to 3 min after switch ON UHF operation fOSC = 405 MHz f from 3 s to 3 min after switch ON UHF operation fOSC = 845 MHz f from 3 s to 3 min after switch ON VHF operation fOSC = 100 MHz f when VCC 5 V changes ±5 % VHF operation fOSC = 405 MHz f when VCC 5 V changes ±5 % UHF operation fOSC = 405 MHz f when VCC 5 V changes ±5 % UHF operation fOSC = 845 MHz f when VCC 5 V changes ±5 %
Min. Typ. Max. Unit
21 24 27 dB 22 25 28 dB 26 29 32 dB 27 30 33 dB
12 15 dB 11 14 dB
8.5 12.5 dB
9.5 13.5 dB
97 101 dBµ
96 100 dBµ
92 96 dBµ
88 92 dBµ +7 +10 dBm
±300 kHz
±400 kHz
±400 kHz
±500 kHz
±150 kHz
±250 kHz
±200 kHz
±250 kHz
OSC/MIX/IF Amplifier Block
1
Measured value for untuned inputs.
2
Noise figure is the direct-reading value of NF meter in DSB.
3
Desired signal (fD) input level is –30 dBm. Undesired signal (fUD) is 100 kHz, 30 % AM. The measurement value is undesired signal level, it measured with a spectrum analyzer at S/I=46 dBm.
4
Value when the PLL is not operating.
—7—
CXA3085AN
Item CL and DA pins “H” level input voltage “L” level input voltage “H” level input current “L” level input current CE pin “H” level input voltage “L” level input voltage “H” level input current “L” level input current CPO (charge pump) Output current Leak current LOCK “H” output voltage “L” output voltage REFOSC Oscillator frequency range Input capacitance Drive level BVL, BVH, BU (Band SW) Output current Saturation voltage Leak current FMT (Band SW) Output current Saturation voltage Leak current Bus timing Data setup time Data hold time Enable waiting time Enable setup time Enable hold time
Symbol
VIH VIL IIH IIL
VIHE VILE IIHE IILE
ICPO LeakCP
VLOCKH VLOCKL
FXTOSC CXTOSC
VXTOSC
IBS1 VSAT1 LeakBS1
IBS2 VSAT2 LeakBS2
tSD tHD tWE tSE tHE
Measurement conditions
VIH = VCC VIL = GND
VIHE=VCC VILE=GND
When locked When unlocked
When ON When ON Sink current = 20 mA When OFF
When ON When ON Sink current = 5 mA When OFF
See Timing Chart on Page 15 See Timing Chart on Page 15 See Timing Chart on Page 15 See Timing Chart on Page 15 See Timing Chart on Page 15
Min. Typ. Max. Unit
3 VCC V
GND 1.5 V
0 –0.1 µA
–1 –2 µA
3 VCC V
GND 1.5 V
100 130 µA –30 –45 µA
±50 ±75 µA
30 nA
VCC–0.5 VCC V
0 0.5 V
3 12 MHz
17.5 19 20.5 pF 200 400 mV
–25 mA
100 200 mV
0.5 3 µA
–7 mA
75 150 mV
0.03 0.1 µA
300 ns 600 ns 300 ns 300 ns 600 ns
PLL Block
Loading...
+ 16 hidden pages