SUPPLEMENTAL SER VICE MANU AL
S32//AFR14CX/
AIR CONDITIONER
AF-R140CX
MODEL
In the interest of user-safety the air conditioner should be restored to
its original condition and only parts identical to those specified should
be used.
This is supplemental Service Manual for Model AF-R140CX.
This model is quite similar to base model AF-R100CX/R120CX. Use this supplemental manual together
with the Base Model Service Manual (Refer No. is S3203AFA12CX/) for complete operation, service
information, etc..
TABLE OF CONTENTS
SPECIFICATIONS ........................................................................................................................................... 2
WIRING DIAGRAM...........................................................................................................................................3
RUNNING CONDITION ....................................................................................................................................3
REPLACEMENT PARTS LIST .........................................................................................................................4
AF-R140CX
Page
SHARP CORPORATION This document has been published to be used for after
sales service only.
The contents are subject to change without notice.
1
AF-R140CX
SPECIFICATIONS
Models AF-R140CX
Cooling capacity BTU/h 13500
Moisture removal Pints/h 3.3
ELECTRICAL DATA
Phase Single
Rated frequency Hz 60
Rated voltage Volts 115
Rated current Amps 12.0
Rated input Watts 1370
Power factor % 99
EER BTU/Wh 9.8
COMPRESSOR
Type (Hermetically sealed rotary type)
Model, Remarks 44B135HX1EF, ????W
REFRIGERANT SYSTEM
Evaporator Slit fin, Grooved tube, Ø 9.53 mm Hair pin
Condenser Louver fin,
Control O.D. x I.D. x Length x Q'ty(mm)
Refrigerant volume R-22(OZ) 21.2(Factory charged)
Capillary tube 2.7 x 1.2 x 800 x 2
Grooved
tube, 7mm Hair pin
NET DIMENSIONS
Width Height Depth
Net Weight lbs 86
GROSS DIMENSIONS
Width Height Depth
Gross Weight lbs 97
FAN SYSTEM
Indoor side(Evaporator) Centrifugal fan
Outdoor side(Condenser) Propeller fan
Air flow rate(indoor side) CFM (High/Med/Low) 339 / 272 / 233
OTHERS
Safety devices Compressor: Overload relay
Air filter Polypropylene net
Power cord length ft 4.3
Power plug type 125V, 15A
ELECTRICAL PARTS
Running capacitor 370V-50µF
Fan capacitor
inches(mm)
inches(mm)
22-1/16(560) x 14-3/4(375) x 24-5/16(617)
25-25/32(655) x 18-29/32(480) x 27-7/8(708)
Fan motor: Internal thermal protector
250V-6µF x 1, 250V-7µF x 1
Thermistor 15k at 78˚F
Fan motor ARS035ZREA/SHP(MLB026)
Overload relay MRA98693-12007
2
WIRING DIAGRAM
Outside air temp. C( F)
Outlet air temp. C ( F)
25 30 35 40
5
10
15
20
25
8
9
10
11
12
13
14
1300
1400
1200
1100
1000
1500
1600
Line current(Amp.) Power input (Wa tt)
(41)
(50)
(59)
(68)
(77)
30
(88)
(77) (86) (96)
(104)
AF-R140CX
POWER SUPPLY CORD
115V 60Hz
RIBBED
NON RIBBED
GR
OVERLOAD
PROTECTOR
COMPRESSOR
MOTOR
RUNNING
CAPACITOR
370V 50µF
FAN MOTOR
CAPACITOR
250V 6µF
BL
BK
OUT
R
RE
GY
RE
OR
GYREOR
H
M.C
A.C
M
WH
WH
L
BL
250V 7µF
BK
BL
BK
123654
BL
BK
THERMAL
PROTECTOR
3A 125V
IN
CONTROL
MRY
BOARD UNIT
BK
BK
C
S
WH
GY
8
7
1
3
5
CONNECTOR
BCN1
FAN MOTOR
Figure W-1
NR
FU1
CNR1
CNR2
CNR3
C1
TR
RY1
RY2
RY3
WIRE COLOR
BK
BL
RE
WH
GR
GY
OR
CN1
THERMISTOR
(
ROOM TEMP
YELLOW TH1
CN2
CN3
: BLACK
: BLUE
: RED
: WHITE
: GREEN
: GRAY
: ORANGE
BCN2
DISPLAY
BOARD
UNIT
BCN3
)
Note:
1. Select mode of the Running Condition of a Room Air
Conditioner.
SELECTOR........................................ HIGH COOL
TEMPERATURE................................ 64°F
2. Data of Performance Curve is measured between 40RH%
and 70RH%.
If you measure the Room Air Conditioner above or
below this rating, the data may miss the range of the
performance curve.
3. Outlet air temp. is influenced by the method of
measurement. Measurement examples are shown.
4. Use power input data when checking the Running
Condition.
RUNNING CONDITION
3
RUNNING CONDITION FOR
PERFORMANCE CURVE