SONY AFR80CX Service Manual

SONY AFR80CX Service Manual

AF-R140CX

SUPPLEMENTAL SERVICE MANUAL

S32//AFR14CX/

AIR CONDITIONER

MODEL AF-R140CX

In the interest of user-safety the air conditioner should be restored to its original condition and only parts identical to those specified should be used.

This is supplemental Service Manual for Model AF-R140CX.

This model is quite similar to base model AF-R100CX/R120CX. Use this supplemental manual together with the Base Model Service Manual (Refer No. is S3203AFA12CX/) for complete operation, service information, etc..

 

TABLE OF CONTENTS

 

Page

SPECIFICATIONS .................................................................................................................

.......................... 2

WIRING DIAGRAM ...........................................................................................................................................

3

RUNNING CONDITION ....................................................................................................................................

3

REPLACEMENT PARTS LIST .........................................................................................................................

4

SHARP CORPORATION

This document has been published to be used for after sales service only.

The contents are subject to change without notice.

1

AF-R140CX

 

 

 

SPECIFICATIONS

 

 

 

 

Models

 

AF-R140CX

Cooling capacity

 

BTU/h

13500

Moisture removal

 

Pints/h

3.3

 

 

 

 

ELECTRICAL DATA

 

 

Phase

 

Single

Rated frequency

 

Hz

60

Rated voltage

 

Volts

115

Rated current

 

Amps

12.0

Rated input

 

Watts

1370

 

 

 

 

Power factor

 

%

99

EER

 

BTU/Wh

9.8

 

 

 

 

COMPRESSOR

 

 

 

 

 

 

Type

 

(Hermetically sealed rotary type)

Model, Remarks

 

44B135HX1EF, ????W

 

 

 

 

REFRIGERANT SYSTEM

 

 

Evaporator

 

Slit fin, Grooved tube, Ø 9.53 mm Hair pin

Condenser

 

Louver fin, Grooved tube, 7mm Hair pin

 

 

 

Control O.D. x I.D. x Length x Q'ty(mm)

Capillary tube 2.7 x 1.2 x 800 x 2

Refrigerant volume R-22(OZ)

21.2(Factory charged)

 

 

 

NET DIMENSIONS

 

 

Width Height Depth

 

inches(mm)

22-1/16(560) x 14-3/4(375) x 24-5/16(617)

Net Weight

 

lbs

86

 

 

 

 

GROSS DIMENSIONS

 

 

Width Height Depth

 

inches(mm)

25-25/32(655) x 18-29/32(480) x 27-7/8(708)

Gross Weight

 

lbs

97

FAN SYSTEM

 

 

Indoor side(Evaporator)

 

Centrifugal fan

Outdoor side(Condenser)

 

Propeller fan

Air flow rate(indoor side)

 

CFM

(High/Med/Low) 339 / 272 / 233

 

 

 

 

OTHERS

 

 

Safety devices

 

Compressor: Overload relay

 

 

 

Fan motor: Internal thermal protector

Air filter

 

Polypropylene net

Power cord length

 

ft

4.3

Power plug type

 

125V, 15A

ELECTRICAL PARTS

 

 

 

 

 

Running capacitor

 

370V-50µF

Fan capacitor

 

250V-6µF x 1, 250V-7µF x 1

 

 

 

 

Thermistor

 

15k at 78˚F

 

 

 

 

Fan motor

 

ARS035ZREA/SHP(MLB026)

 

 

 

 

Overload relay

 

MRA98693-12007

 

 

 

 

2

AF-R140CX

WIRING DIAGRAM

 

POWER SUPPLY CORD

 

3A 125V

 

WIRE COLOR

115V 60Hz

 

 

BK : BLACK

IN

 

 

NON RIBBED

FU1

BL : BLUE

GR

MRY

CONTROL

 

RE : RED

OUT

BOARD UNIT

WH : WHITE

 

BK

 

 

GR : GREEN

 

NR

 

GY : GRAY

OVERLOAD

C1

PROTECTOR

 

OR : ORANGE

 

 

 

 

COMPRESSORC

BK

TR

THERMISTOR

 

MOTOR

 

RIBBED

 

CN1

(ROOM TEMP)

 

RUNNING

R

S

 

YELLOW

TH1

 

CAPACITOR

RE

WH

CNR1

 

370V 50 F

 

 

FAN MOTOR

 

 

 

CNR2

CN2

BCN2

CAPACITOR

 

GY

8

 

 

 

250V 6 F

GY

CNR3

 

DISPLAY

BL

BK

 

7

 

RE

 

RY1

 

 

1

 

BOARD

 

 

OR

 

RY2

 

UNIT

 

 

 

3

 

 

 

WH

 

RY3

 

 

BL

BK

 

5

 

 

 

 

 

 

 

250V 7 F

1 2 3 6

5 4 CONNECTOR BCN1

CN3

BCN3

 

BL BK GY RE OR WH

 

 

 

H

M L

FAN MOTOR

 

 

THERMAL

 

 

 

 

 

 

 

PROTECTOR

 

 

 

 

BK

M.C

 

 

 

 

BL

A.C

 

 

 

Figure W-1

RUNNING CONDITION

Note:

1.Select mode of the Running Condition of a Room Air Conditioner.

SELECTOR ........................................

HIGH COOL

TEMPERATURE ................................

64°F

2.Data of Performance Curve is measured between 40RH% and 70RH%.

If you measure the Room Air Conditioner above or below this rating, the data may miss the range of the performance curve.

3.Outlet air temp. is influenced by the method of measurement. Measurement examples are shown.

4.Use power input data when checking the Running Condition.

RUNNING CONDITION FOR

PERFORMANCE CURVE

 

1600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tt)

1500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Wa

1400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

input

1300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

current(Amp.)

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Line

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(88)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

( F)

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(77)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

temp.

(68)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

air

(59)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outlet

(50)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(41)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

30

35

40

 

(77)

(86)

(96)

(104)

Outside air temp. C(F)

3