SERVICE MANUAL
AE-5A
CHASSIS
MODEL
KV-29FQ75A
KV-29FQ75D
COMMANDER DEST CHASSIS NO.
RM-893 ET SCC-Q45A-A
RM-893 AEP SCC-Q41D-A
MODEL
KV-29FQ75E
KV-29FQ75K
COMMANDER DEST CHASSIS NO.
RM-893 ESP SCC-Q43A-A
RM-893 OIRT SCC-Q42B-A
1
SECTION 4 CIRCUIT ADJUSTMENTS
4-1. Electrical Adjustments
Service adjustments to this model can be performed using the supplied Remote Commander RM-893.
How to enter into the Service Mode
1. Turn on the main power switch of the set while pressing P + (plus) and P - (minus) buttons on the front drop down control panel.
++
s
4
L/G/S/I R/D/D/D
4
MONO
4
2. ‘TT’ will appear in the upper right corner of the screen.
3. Press the ‘MENU’ button twice on the remote commander to obtain the service menu on the screen.
P
__
RESET DEVICES
Backend
Deflection
Ext Deflection
Dynamic Convergence
Colour Decoder 1
Colour Decoder 2
Audio/Video Switch
Mid-X
External PLL Mid-X
Sound
Analog NR
SERVICE MENU
Initialising
Reset Devices
Monitoring
Device Register Setting
Special Adjustment
Select :
Next Menu
4. Push the joystick up or down on the remote commander to select the adjustment item.
5. Push the right button to proceed to the next menu.
6. If the required adjustment item is ‘Deflection’, push the down button to move to ‘Deflection’.
7. Push the joystick to the right to enter into ‘Deflection’.
8. Change the data in order to comply with each standard.
INITIALISING
Model Setting
Destination Setting
Basic Setting
Feature Setting
MONITORING
Device Status monitor
Error Monitor
Production Monitor
NVM Monitor
Format Monitor
CNI Monitor
Note :
• Before performing any adjustments ensure that the correct model has been selected in the ‘Model Setting’ menu.
• After carrying out the service adjustments, to prevent the customer accessing the ‘Service Menu’ switch the TV set OFF and then ON.
24