Service
SK 100
SK 300
SK 500
Part 1
Sennheiser electronic GmbH & Co. KG • D-30900 Wedemark • Tel. 0 51 30 / 600-0
SK 100, SK 300, SK 500
Änderungen vorbehalten / Subject to alterations / Sous réserve de modification
05/00 – 1
(Werte in Klammern entsprechen typischen Werten)
HF-TEIL
Frequenzaufbereitung ________________________________________ Phase-Locked-Loop (PLL)-Synthesizer Frequenzbereiche ___________________________________________ 518 ... 550 MHz
630 ... 662 MHz
740 ... 772 MHz
790 ... 822 MHz
838 ... 870 MHz Schaltbandbreite ____________________________________________ max. 32 MHz
Kanalanzahl _________________________________________________ SK 500: 16; SK 300: 8; SK 100: 4 Frequenzraster ______________________________________________ 25 kHz
HF-Leistung am Antennenausgang ____________________________ 30 mW, -3 dB
Modulationsart ______________________________________________ FM
Nennhub bei 1 kHz NF _______________________________________ ± 24 kHz
Spitzenhub bei 1 kHz NF _____________________________________ ± 48 kHz
NF-TEIL
Kompandersystem __________________________________________ HDX |
|
|
|
|
|
NF-Frequenzgang (bei 1 kHz) __________________________________ 100 Hz ... 16 kHz; -3dB |
|
||||
Klirrfaktor bei 1 kHz und Nennhub _____________________________ < 0,9% (0,5%) |
|
|
|||
S/N-Verhältnis (A-bewertet) ___________________________________ ≥ |
100 dB |
|
|
|
|
S/N-Verhältnis (ohne Expander) ________________________________ ≥ |
60 dB |
|
|
|
|
(bei Spitzenhub, NF 1 kHz, Verstärkung -30 dB) |
|
|
|
|
|
Eingangsempfindlichkeit bei Nennhub |
|
|
|
|
|
Mikrofon _________________ 19 |
/38 |
/120 |
/390 |
mV |
|
Gitarre ___________________ 0,13 |
/0,32 /0,7 |
/2,2 |
V |
||
Eingangsempfindlichkeit bei Spitzenhub (Klirrfaktor ≤ 3%) |
|
|
|
|
|
Mikrofon _________________ 60 |
/120 |
/380 |
/1200 mV |
||
Gitarre ___________________ 0,4 |
/1,0 |
/2,2 |
/2,4 |
V |
|
Eingangswiderstand bei 1 kHz NF _____________________________ ≥ |
10 kΩ |
|
|
|
ALLGEMEIN
Nennspannung ______________________________________________ 9 V Betriebsspannung ___________________________________________ 6,0 ... 10 V Stromverbrauch bei Nennspannung ____________________________ ≤ 56 mA (52 mA) Ruhestromaufnahme ________________________________________ ≤ 100 µ A
Batterie ____________________________________________________ IEC 6LR61 (PP3,6 AM 6,9V-E-Block Alkaline) Betriebszeit _________________________________________________ ≥ 8 Stunden (Varta Nr. 4022 oder 8022) Zulassung __________________________________________________ D810 003L RF / FCC ID: DMOB1EURH
SK 100, SK 300, SK 500 |
Änderungen vorbehalten |
|
|
05/00 – 2 |
|
(Values in brackets are typical values)
RF STAGE
RF Generation and control ____________________________________ Phase-Locked-Loop (PLL)-Synthesizer Frequency ranges____________________________________________ 518 ... 550 MHz
630 ... 662 MHz
740 ... 772 MHz
790 ... 822 MHz
838 ... 870 MHz Switching bandwidth _________________________________________ max. 32 MHz
Quantity of channels _________________________________________ SK 500: 16; SK 300: 8; SK 100: 4 Channel grid ________________________________________________ 25 kHz
RF Power at antenna output __________________________________ 30 mW, -3 dB
Modulation _________________________________________________ FM
Nominal deviation at 1 kHz AF _________________________________ ± 24 kHz
Peak deviation at 1 kHz AF ____________________________________ ± 48 kHz
AF STAGE
Compander sytem ___________________________________________ HDX
AF-Frequency response (ref. 1 kHz) ____________________________ 100 Hz ... 16 kHz; -3dB THD at 1 kHz and nominal deviation ____________________________ < 0.9% (0.5%)
S/N ratio A-weighted _________________________________________ ≥ 100 dB S/N ratio excl.expander _______________________________________ ≥ 60 dB (both ref. peak deviation, AF 1 kHz, gain -30 dB)
Input sensitivity for nominal deviation
mic. _____________________ 19 |
/38 |
/120 |
/390 |
mV |
guit. _____________________ 0.13 |
/0.32 /0.7 |
/2.2 |
V |
|
Peak input (THD ≤ 3%) |
|
|
|
|
mic. _____________________ 60 |
/120 |
/380 |
/1200 mV |
|
guit. _____________________ 0.4 |
/1.0 |
/2.2 |
/2.4 |
V |
Input Resistance at 1 kHz AF __________________________________ ≥ 10 kΩ
GENERAL
Nominal supply voltage _______________________________________ 9 V Operating voltage ___________________________________________ 6.0 ... 10 V
Current consumption at nominal voltage ________________________ ≤ 56 mA (52 mA) Stand-by current _____________________________________________ ≤ 100 µ A
Battery _____________________________________________________ IEC 6LR61 (PP3.6 AM 6.9V-E-Block Alkaline) Operating time ______________________________________________ ≥ 8 Hours (Varta No. 4022 or 8022) Approbation ________________________________________________ D810 003L RF / FCC ID: DMOB1EURH
Subject to alterations |
SK 100, SK 300, SK 500 |
|
|
|
05/00 – 3 |
SK 100, SK 300, SK 500
SK 100, SK 300, SK 500 05/00 – 4