Sonitrol GS3-LF Installation Manual

GS3-LF Panel Reader
Installation Guide
171006 v1.03 DRAFT 91 Jul 2013
2
GS3-LF Panel Reader
Installation Guide
Guide d’installation
GS3-LF Lector para Montaje en Panel
Guía de instalación
GS3-LF Lettore a pannello
Guida all’installazione
GS3-LF Leitor de painel
Guia de Instalação
GS3-LF Paneelilukija
Asennusopas
3
Parts · Pièces · Piezas
P/N 909070117
×1 ×1 ×1
MOV
Dimensions · Dimensions · Dimensiones
16
75
60
48.5
48.5
40
40
All dimensions mm · Toutes dimensions en mm · Todas las dimensiones en mm
4
Connections · Connexions · Conexiones
12-24V
D1/SIG
LED
0V/GND
D0/CLK
TAMP
SOUND
+V / 12V–24V D1 / SIG LED 0V / GND D0 / CLK Tamper · Effraction · Manip. fraud. Sounder · Alarme sonore · Sonido Do not use · N’utiliser pas · No utilice
Cable Routing · Routage du câble · Recorrido del cable
5
Output Format · Format de Sortie · Formato de Salida
Default Settings · Paramètres standards · Ajustes estándares
Output Format Format de sortie Formato de Salida
Card / Token Carte / Fiche Tarjeta / Ficha
DIP
Wiegand 74-bit
ON
1 2 3 4 5
PAC / KeyPAC
WiegandWiegand Prox
Wiegand 34-bit
ON
1 2 3 4 5
PAC / KeyPAC Wiegand Prox
Wiegand 26-bit
ON
1 2 3 4 5
PAC / KeyPAC Wiegand Prox
Wiegand 74-bit
ON
1 2 3 4 5
PAC / KeyPAC Wiegand Prox
Other Settings · Autres paramètres · Otros ajustes
Output Format Format de sortie Formato de Salida
Card / Token Carte / Fiche Tarjeta / Ficha
DIP
Magstripe
ON
1 2 3 4 5
PAC / KeyPAC Wiegand Prox
PAC
ON
1 2 3 4 5
PAC / KeyPAC Wiegand Prox
PAC 64
ON
1 2 3 4 5
PAC / KeyPAC Wiegand Prox
6
Symbols · Symboles · Símbolos
Data from card · Les données de la carte · Los datos de tarjeta
Padded or truncated data · Les données sont complétées ou tronquées · Los datos se rellenan o se truncan
Processed data · Les données sont traitées · Los datos se procesan
OPS processeddata ·Les donnéessont traitéescomme OPS· Losdatos seprocesan como OPS
Reader Configuration · Configuration du lecteur · Configuración de lector
Result · Résultat · ResultadoDIP
Reader beeps when token presented Le lecteur émet un bip lorsque la fiche est présenté Lector pita cuando una tarjeta es presentada
ON
1 2 3 4 5
Reader silent when token presented Le lecteur reste silencieux lorsque la fiche est présenté Lector silencia cuando una tarjeta es presentada
ON
1 2 3 4 5
7
English
Installation
1. Ensure your product comes with the items indicated on page 4; if not please contact your dealer.
2. Mount reader within panel so that the front cover fits through the aperture and clamp using nuts suitable for the studs.
3. Connect cable to circuit board — see page 5.
4. Set output format — see page 6.
5. Configure reader — see page 7.
6. Apply power when all readers are installed.
Notes
The reader is designed to fit within a standard reader panel. Holes on the reader accept M3 (metric) / #4 (UTS) posts.
Mount readers >3 / 1m apart, e.g. on either side of the door. Mounting on metal
surfaces will reduce the reading range.
If the reader is being used to enter credential information to arm a system, the
reader must be located within 3 / 1m of the panel’s main keypad or display.
For outside readers, use corrosion-resistant fixings and apply silicone sealant to the backplate before fixing to the wall.
The suppliedMOV (Metal Oxide Varistor, AngliaComponents P/NB72207S250K101) should be fitted across the power terminals of the lock to suppress back EMF. Any suppression diodes fitted in the lock / lock circuit must be removed.
Output format and reader configuration can be changed without disconnecting the power supply. The reader automatically restarts with the new configuration.
8
English
Usage
LEDs
Red / GreenGreenRed
Access deniedAccess permittedDefault
Sounder
The reader sounds 4 rapid beeps when it is powered up or restarted.
If specified, the reader beeps once when a token is presented.
Cable Lengths
Sonitrol door controllers only
Distance from Reader to ControllerCable Gauge
230 / 70m *7/0.2 0.34mm² 22AWG 230 / 70m *16/0.2 0.5mm² 20AWG 230 / 70m *32/0.2 1.0mm² 18AWG
Notes
These figures (*) are for readers powered from the controller. The cable distances
can be increased to 1650 / 500m by locally powering the readers.
Locally powered readers must be connected to a UL 603 power limited Class 2 supply for US, or a ULC S318 power limited Class 2 supply for Canada.
If you use 22AWG / 0.34mm² cables, twist the wires and double them over before inserting them in the crimps.
Maximum cable distances will be less for readers which have been set to give Wiegand output.
Specification
CurrentPowerReader Range
90mA12V–24V DCUp to 4.0 / 100mm
9
English
Note
Maximum current draw is lower at 24V.
Temperature
StorageOperating
-40°C — +66°C / -40°F — +151°F-40°C — +66°C / -40°F — +151°F
Humidity
Operating for 24 hours
Tested at 93% for ULC S319.10-85% RH @ 30±2°C / 85±4°F
Ingress Protection
IP65 afterinstallation — evaluated by lab separate from UL. Installermust adequately seal any connections made.
Weight
90g
10
English