AUDIO INTERFACES
Redbox - Synchronisers, Delays & Silence Detectors
RB-SD1 Silence Detection Unit (continued...)
61 Station Road, Irthlingborogh, Northants, NN9 5QE, United Kingdom Tel: +44 (0)1933 650 700 Fax: +44 (0)1933 650 726 Email: sales@sonifex.co.uk Internet: www.sonifex.co.uk
Audio Specification For RB-SD1
Maximum
Input Level: +28dBu
Maximum
Output Level: +28dBu
Frequency
Response: 20Hz - 20kHz ±0.1dB
Gain: +8dB (for unbal input B - optional)
Distortion: As input for balanced input, <0.05% ref
+8dBu output for unbalanced input
Input
Impedance: >100kΩ balanced
Output
Impedance: As input, except when using
unbalanced auxiliary input where
output impedance <50Ω
Noise: <-87dB, unity gain, ref +8dBu output
for unbal input
Rear Panel Connections and Controls
Inputs (Main
& Auxiliary): 4 x XLR 3 pin female (balanced,
auxiliary can be unbalanced)
Output: 2 x XLR 3 pin male (balanced)
Remotes: 15 way D-type plug
Alarm Threshold:-15dBu to -60dBu in 3dB steps via
rotary switch
Silence Detect
Duration: 2 - 30 seconds in 2 second intervals &
125 second option via rotary switch
Detection Type: Mono or stereo, via DIP switch
Silence Switch
Defeat: Disable/enable silence switching, via
DIP switch
Remote Start: Latched or momentary, via DIP switch
Mains Input: Filtered IEC, switchable 110-120V, or
220-240V, fused, 9W max
Front Panel Controls and Indicators
Controls (with
indicators): Source select, mode select and restore
Indicator: Program and alarm indicators for left
and right source for both main and
auxiliary channels
Equipment Type
RB-SD1: Silence detection unit
Physical Specification
Weight: Nett: 1.4kg Gross: 2.0kg
Dimensions 48cm (W) x 10.8cm (D) x
(Raw): 4.2cm (H) (1U)
(Boxed): 53cm (W) x 20.5cm (D) x 6cm (H)
signal fails. There are also options to set the
remote start output as momentary or
latched, to disable switching to the auxiliary
input on alarming and to increase the gain
on the auxiliary input so that an unbalanced
input can be used, for example, from a
domestic minidisc player.
Front panel LED indicators show individually
left and right programme and alarm
conditions for both the main and auxiliary
inputs. The status of the source, mode and
alarm state are also shown on the front
panel with LED indicators.
Additionally, the RB-SD1 can be
programmed for specific applications which
can be defined on power-up of the unit.
Contact Sonifex for further information if
you have a particular requirement. (Refer to
the handbook on the website for
information on current configurations).
The RB-SD1 has been designed to have a
passive signal path through the main input,
so if power to the unit fails, the signal input
will still be routed through to the output.
This is essential for applications such as
installation at transmitter sites, where a
power failure to the unit should not prevent
the audio input signal from being output to
the transmitter.
<< previous page