Sonance Two Zone Connecting Block CB2Z Installation Instructions Manual

Page 1
The Model CB2Z is a device that provides routing of infrared remote control signals. Independent
control of two audio/video systems can be obtained from two zones. One emitter port is provided for each zone, plus one common port so that certain components can be controlled from both zones. The CB2Z is a simplified unit, intended for use when only two zones are needed.
INSTALLATION INSTRUCTIONS
CB2Z
TWO ZONE CONNECTING BLOCK
Fig. 1: CB2Z Two Zone Connecting Block
Mounted in 3” SNAPTRACK
®
(SNAPTRACK is a registered trademark of AUGAT)
SPECIFICATIONS
• Inputs: 2 - Four screw removable connectors to interface with all 3-wire IR receivers (see Caution Note, Fig. 2, below)
• Outputs:Two zone emitter ports and 1 common emitter port (3.5mm miniature phone jacks).
• Can be used with a CB1 Connecting Block or
an ACB1 Amplified Connecting Block for COMMON emitter expansion. (See Fig. 4 & 5)
• Uses Sonance E1, VE1, E2 and VE2 Mini Emitters.
• Power requirements: 12 volts DC. Uses PS1
or PS2 Power Supplies.
• 2.1 mm coaxial power jack.
• Dimensions: 2-3/8"W x 3"D x 13/16" H.
CAUTION: For Shielded Wire and Long Lead Lengths
When using lengths greater than 200 feet of inter-room shielded cable, it may be necessary to connect a 470 Ohm 1/8 Watt resistor between I N P U T (SIG) and GROUND (GND) at the IR input terminals of the CB2Z. Refer to Fig. 2, above. The resistor discharges the cable capacitance more quickly, allowing IR codes of high bit
Fig. 2: 470 Ohm Capacitance
Discharge Resistor
Page 2
Fig. 3: A Typi cal Two-Zone
NOTE: For clarity, connections to the 3­conductor cables in this illustration are shown in "daisy chain" fashion. It is recommended that 3­conductor "home-runs" be pulled from each room to the CB2Z Connecting Block in the main room. This maintains higher power supply voltage
INSTALLATION
Fig. 3, see below, shows a typical two-zone installation with a total of four remote rooms. A variety of Sonance IR
Receivers are shown, two in each zone. When configuring a system, please keep the following items in mind:
1. More IR Receivers may be wired in parallel, in the same manner as shown, up to a maximum of 12. More than 12 is not recommended because IR noise picked up by the many IR receivers may cause erratic operation and reduce remote control range.
2. Be sure to connect the +12VDCpower, SIGNAL output, and G N D ground of each IR Receiver or keypad to the respective +12VDC, SIGNAL and GND of the connecting block as shown.
Page 3
Pg 3
Power Supply Requirement:
1. Most IR receivers draw 2 milliamps (mA) without signal and 10 mA with signal (check specs. on actual model).
2. The maximum current for proper operation from the PS1 Power Supply is 200 ma.
3. The maximum current for proper operation from the PS2 Power Supply is 1000 ma.
4. When using combinations of receivers, do not exceed the maximum current ratings of the power supplies as noted above.
For example, 6 IR receivers and 4 emitters could be used with one PS1 Power Supply. If the current
of the PS1 will be exceeded, use the PS2 power supply instead. NOTE:
To avoid current "hogging", never connect regulated supplies, such as the PS1 and PS2, in parallel!
CAUTION:
Do not use unregulated 12V power supply adapters from other manufacturers. These may deliver excessive voltage to the IR receivers and cause them to “latch-up”. When this occurs, the “talkback” LEDs and VE1 emitters (if used) will stay on continuously!
EMITTTER EXPANSION
Fig. 4, below, shows the single common emitter port on the CB2Z connected to a CB1 Connecting
Block (or an ACB1 Amplified Connecting Block). Also, if you need to drive more than 4 signal emitters from the common port, they must be driven by an ACBI Amplified Connecting Block.
Fig. 4: Using CB1 for Emitter Expansion
NOTE:
No power supply is connected to the CB1!It is not needed when the CB1 is used strictly as an expansion block, as it is in this example. Also, if you need to drive more than four single emitters from the COMMON port, they must be driven by an ACB1 Amplified Connecting Block. See Fig. 5, next page.
Page 4
Pg 4
Fig. 5: Using a ACB1 for Emitter Expansion
©2002 Sonance. All rights reserved.
33-1891 4.02
CAUTION:
Because the ZONEand COMMONjacks on the CB2Z are connected in series, you must have an emitter(s), a connecting block (with emitters), or other Sonance IR controlled device plugged into the COMMON jack for the zone emitters to operate! This is true for the ZONE OUTPUT jacks as well.
MOUNTING
The CB2Z can be conveniently mounted to a wall or shelf by using screws or mounted into 3”
SNAPTRACK
®
.
CAUTION:
Because the ZONEand COMMONjacks on the CB2Z are connected in series, you must have an emitter(s), a connecting block (with emitters), or other Sonance IR controlled device plugged into the COMMON jack for the zone emitters to operate! This is true for the ZONE OUTPUT jack as well.
Fig. 5, below, illustrates an ACB1 driving six emitters for control of six common components. Up
to 10 single or 10 dual emitters may be driven directly from the ACB1.
SONANCE • 212 Avenida Fabricante • San Clemente, CA 92672
www.sonance.com