Somfy UNIVERSAL RTS INTERFACE II, URTSI II Installation Manual

Page 1
DESCRIPTION
Part Number: 1810872
Back of Interface control box
UNIVERSAL RTS INTERFACE II
Operating Instructions
The addressable Universal RTS Interface II (URTSI II) can be used to communicate between home automation or other third party systems and SOMFY’s RTS Motors and controls. It is capable of individual or group control, and can be operated via infrared remote, RS232 and RS485 serial communication. Once an input is activated, an RTS radio command is sent to the automated window treatment.
IR Sensor Modular Pin-Out
(Shown Tab-side Down)
Pin 4
IR Signal
Antenna
IR Sensor Input
RS232 Input
or RS485 Input
NOTE: Do Not remove antenna. If a new antenna is needed, it must be ordered from Somfy to ensure FCC requirements are maintained.
UP Button
STOP Button
DOWN Button
Front of Interface control box
0
1
F
2
E
3
D
4
C
5
B
6
A
7
8
9
Power
RS485 Input/Output
Power/Transmit LED
URTSI Address or
RTS Channel
Rotary Switch
Program Button
Pin 1
RS232/RS485 Pin-Out
(Shown Tab-side Down)
Pin 8
Pin 1
* As an option, power to the URTSI II can be
supplied on leads 4 & 5. In this case, the plug-in transformer is not needed. In addition, the power can be daisy-chained to the next URTSI II over the CAT5 cable. The power supply should be sized based on the number of Interfaces on the network segment.
Common
+5V DC
N/C
Common
RS232 RX
Bus Power Supply*
RS232 TX
RS485 B
RS485 A
FCC INFORMATION
This device complies with Part 15 of the FCC Results. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including that which may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for CLASS B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and , if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1. Reorient or relocate the receiving antenna
2. Increase the separation between the equipment and receiver
3. Connect the equipment into an outlet on a circuit different from that to which receiver is connected
4. Consult the dealer or experienced radio/TV technician for help.
Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
WARNING
Page 2
OPERATION
A. INITIAL SETUP
1. Connect a 9v DC transformer (included) to the receptacle on the back of the control box. The LED will light green to indicate power.
2. Be careful not to mount or enclose Interface on or in metal, as this may effect radio reception.
3. Set the RTS Receiver or motor into its Programming Mode. Refer to the installation instructions of the relevant RTS receiver or motor for this procedure. NOTE: for initial programming provide power only to the motor or control being programmed.
4. Using the rotary switch, select the channel to be programmed. Letters A through F stand for channels 10 through 15, 0 for 16. Briefly press the programming button
(1 sec. max), the window treatment will jog to indicate the channel has been memorized.
5. Repeat the steps above for each channel or product to be memorized, up to 16.
6. To test the control operation, simply press the UP, STOP or DOWN buttons on the front of the control. The window treatment should move appropriately. The LED will
flash red to indicate the radio signal has been transmitted.
B. INFRARED OPERATION
1. The RTS Interface is compatible with Somfy’s multichannel transmitter. Connect an infrared sensor to the appropriate connector on the back of the Interface.
2. Each individual motor is activated by first aiming the transmitter at the sensor and pressing the desired unit number on the transmitter and then pressing the UP or
DOWN buttons. Press the center button to STOP the window treatment at any time.
3. The Infrared Channel stays active for 3 minutes. After that, the channel must be reselected.
C. RS232 OPERATION
1. The Somfy RS232 interface uses the following communications settings: 9600 Baud, 8 Data Bits, 1 Stop Bit, No Parity
2. Set the rotary switch to position 1.
3. The basic format for communication is as follows: URTSI ADDR MOTOR CHAN DIR
The URTSI II address is 01.
The motor channel should be 2 digits from 01 to 16.
The directional commands are: U = Up D = Down S = Stop (Must be Capital letters)
4. Examples:
Motor 1 UP: 0101U Motor 5 DOWN: 0105D Motor 12 STOP: 0112S
D. RS485 OPERATION
1. The Somfy RS485 interface uses the following communications settings: 9600 Baud, 8 Data Bits, 1 Stop Bit, No Parity
2. With RS485, it is possible to connect 16 Universal RTS Interfaces on one network. Each Interface will have its own address. To select the address, set the rotary switch to the desired number. Letters A through F stand for addresses 10 through 15, 0 for 16.
3. The basic format for communication is as follows: URTSI ADDR MOTOR CHAN DIR The URTSI II address should be 2 digits from 01 to 16.
The motor channel should be 2 digits from 01 to 16.
The directional commands are: U = Up D = Down S = Stop (Must be Capital letters)
4. Examples:
URTSI 1, Motor 1 UP: 0101U URTSI 3, Motor 12 DOWN: 0312D URTSI 14, Motor 9 STOP: 1409S URTSI 10, Motor 15 UP: 1015U
MECHANICAL SPECIFICATIONS
Overall Dimensions: L: 3 in. W: 4 in. D: 1 /8 in.
Typical Range (Optimal Conditions): 65 ft.
3
ORDERING INFORMATION
Description
Universal RTS Interface II
MultiChannel Infrared Transmitter IR Sensor
SOMFY CANADA
6315 Shawson Drive, Unit #1 Mississauga, Ontario L5T1J2
SOMFY SYSTEMS, INC. reserves the right to change, update or improve this document without prior notice.
Part Number
1810872 1810498 9015078
ELECTRICAL SPECIFICATIONS
Power: 9 - 15 V DC, 200mA
Frequency: 433.42 Mhz
Description
DB9 to RJ45 Adapter for RS232 DB9 to RJ45 Adapter for RS485
Ref. No. 2500872A
20mA draw for each Universal Interface
SOMFY SYSTEMS, INC.
47 Commerce Drive Cranbury, NJ 08512
C
Part Number
9015028 9015029
SOMFY SYSTEMS, INC. 10/08
Loading...