SOMFY SOLIRIS RTS Installation Manual

The SOLIRIS sensor RTS is a radio sensor for awnings with an automatic control according to the daylight intensity and protection against wind damage.
The wind and sun thresholds can be set directly on the SOLIRIS sensor RTS. The SOLIRIS sensor RTS must be used with the OREA RTS and ALTUS RTS
motors.
®
(Find in annex the CE declaration of conformity)
inteo SOLIRIS sensor RTS
INSTALLATION
guide
Ref.9000838
Installation:
1
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,
,,,,
,
,,,,
,
,,,,
,
,,,,
,
,,,,
,
,,,,
,
,,,,
,
Press for more than 2 seconds on the programming
button of an RTS control which is already memorized in the motor.
(please refer to the installation guide of the relevant motor).
Press briefly on the “prog”button of the SOLIRIS sensor RTS.
236 mm
160 mm
Connect the cable to the terminal.
Put the cover on
Fix the sensor to the wall.
Place and screw on the front box.
MAINS
230V - 50Hz
2 wires x 0,75 mm
2
Neutral
Phase
>2 sec.
prog
The motor must be in learning mode to record a SOLIRIS sensor RTS. Up to three SOLIRIS sensors RTS can be memorized in one motor and one SOLIRIS sensor RTS can be memorized in several motors.
Programming:
2
Characteristics
Mounting
Cabling
The awning moves momentarily (DOWN/UP).
the motor is in “learning”mode.
Enter the “learning” mode Record or delete a sensor
The awning moves momentarily (DOWN/UP).
If it is a new sensor :it will be recorded in the motor. If the sensor was already recorded : it will be erased.
Press for more than 7 sec. on the “prog”button of the new SOLIRIS sensor RTS.
Erase all the sensors and record a new one
The awning moves momentarily (DOWN/UP).
the memory of the receiver is cleared (all the previous sensors are erased) and the new sensor is recorded.
prog
>7 sec.
0165
When the daylight level falls below the threshold
setting, a variable time delay from 15 to 30 minutes is activated (depen­ding on the sun presence duration).
This feature avoids frequent movements of the awning on cloudy days.
The SOLIRIS sensor RTS is able to control and protect an awning according to the sun and wind conditions by controlling the OREA RTS or the ALTUS RTS motors.
The WIND and SUN thresholds can be adjusted by two potentiometers,one for wind speed and one for daylight intensity. Between 10 to 50 Km/h for the WIND and between 0 to 50 klux for the SUN.
By using the TELIS SOLIRIS RTS remote control, it is possible to configure the functioning of the receiver (wind only or wind/sun). Please refer to the TELIS SOLIRIS RTS installation guide.
On the ALTUS RTS and OREA RTS motors, a short UP/DOWN movement of the awning indicates the modification of the configuration.
As long as the measured wind speed is higher than the adjusted threshold, all commands are inhibi­ted (manual control or automatic control) .
When the intensity of the daylight exceeds the thre­shold set by the SOLIRIS sensor RTS,a DOWN order is sent to the awning after 2 mins.
The awning goes to the intermediate position (see the motor ins­tallation guide) or to its down end limit position if no intermediate position has been memorised.
After this time delay,an UP order is given to the awning.
Any manual com­mand given during this cycle will override the automatic operation. The SOLIRIS sensor RTS will not then function automatically until the daylight exceeds the threshold limit again.
IP
When the wind speed exceeds the threshold set by the SOLIRIS sensor RTS, an UP order is given to the awning after 2 secs.
IP
In this mode all delay times are reduced to ease installation and the wind threshold is 10Km/h. The mode is selected by turning the wind poten­tiometer clockwise to the limit.
after 15 to 30 mins.
after 2 secs.
When the wind speed falls below the thre­shold setting, the SUN function remains inhibited for 12 minutes, but after 30 seconds, an order can be given with the RTS control.
after 12 min.
after 30 sec.
Functionning:
3
®
SUN function
WIND function
DEMO mode
Timings (with OREA RTS and ALTUS RTS)
Normal mode Demo mode SUN appearing timing 2 min. 10 sec. SUN disappearing timing 15/30 min. 15 sec. WIND appearing timing 2 sec. 2 sec. WIND disappearing timing 30 sec. 12 min. 15 sec.
Loading...