SOLTEC Soluzioni Tecnologiche SK33039 User Manual

SOLTEC
Soluzioni Tecnologiche S.r.l.
MultiTag Rfid System
KIT33039
13.56 MHz ‘R’ version FW version 1.15F
‘KIT33039’ manual - Rev. 1 Pag 1 of 22
SOLTEC
Soluzioni Tecnologiche S.r.l.
Preface
SOLTEC Soluzioni Tecnologiche S.r.l. (SOLTEC) reserves the right to make changes to its products or services or to discontinue any product or service at any time without notice. SOLTEC provides customer assistance in various technical areas, but does not have full access to data concerning the use and applications of customer's products. Therefore, SOLTEC assumes no liability and is not responsible for customer applications or product or software design or performance relating to systems or applications incorporating SOLTEC products. In addition, SOLTEC assumes no liability and is not responsible for infringement of patents and/or any other intellectual or industrial property rights of third parties, which may result from assistance provided by SOLTEC. SOLTEC products are not designed, intended, authorized or warranted to be suitable for life support applications or any other life critical applications that could involve potential risk of death, personal injury or severe property or environmental damage. With the edition of this document, all previous editions become void. Indications made in this manual may be changed without previous notice. Composition of the information in this manual has been done to the best of our knowledge. SOLTEC does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips. The installation instructions given in this manual are based on advantageous boundary conditions. SOLTEC does not give any guarantee promise for perfect function in cross environments. The companies or products mentioned in this document might be brands or brand names of the different suppliers or their subsidaries in any country. This document may be downloaded onto a computer, stored and duplicated as necessary to support the use of the related SOLTEC products. Any other type of duplication, circulation or storage on data carriers in any manner not authorized by SOLTEC represents a violation of the applicable copyright laws and shall be prosecuted.
Safety Instructions / Warning - Read before start-up!
The device may only be used for the intended purpose designed by the manufacturer. The operation manual should be conveniently kept available at all times for each user.
Unauthorized changes and the use of spare parts and additional devices that have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer.
The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the
‘KIT33039’ manual - Rev. 1 Pag 2 of 22
SOLTEC
nt has been tested and found to comply with the
limits for a Class A digital device, pursuant top art 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
l
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the I
nstruction manual, may cause harmful interference to radio
ntial area is
likely to cause harmful interference in which case the user will be
manual or automatically set parameters for a device or for an incorrect application of a device.
Repairs may be executed by the manufacturer only.
Only qualified personnel should carry out installation, operation, and
maintenance procedures.
Use of the device and its installation must be in accordance with national legal requirements and local electrical codes.
When working on devices the valid safety regulations must be observed.
Note: This equipme
harmful interference when the equipment is operated in a commercia
communications. Operation of this equipment in a reside required to correct the interference at his own expense.
NOTICE: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including
NOTICE: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(3) this device may not cause harmful interference, and (4) this device must accept any interference received, including
Soluzioni Tecnologiche S.r.l.
interference that may cause undesired operation.
interference that may cause undesired operation.
‘KIT33039’ manual - Rev. 1 Pag 3 of 22
SOLTEC
Soluzioni Tecnologiche S.r.l.
‘KIT33039’ manual - Rev. 1 Pag 4 of 22
SOLTEC
Soluzioni Tecnologiche S.r.l.
Table of contents
1. Introduction page 6
2. Technical specifications 6
3. Operating features 7
4. Communication features (protocol) 8
4.1. Parameters programming 10
4.2. Default parameters programming 12
4.3. FW version reading 12
4.4. Status reading 13
4.5. RF deactivation 14
4.6. RF activation 14
4.7. Inventory of ISO 15693 transponders 15
4.8. Reading of a data block of an ISO 15693 transponder 15
4.9. Writing a data block to an ISO 15693 transponder 16
4.10. Locking a data block of an ISO 15693 transponder 17
5. HW settings – SW1 and SW11 DIP switches 19
6. External connections 20
7. Status indication: leds and buzzer 21
8. Antenna 22
9. Installation 22
‘KIT33039’ manual - Rev. 1 Pag 5 of 22
SOLTEC
Board dimensions
67mm x 94mm
Soluzioni Tecnologiche S.r.l.
1. Introduction
The reader of the KIT33039 is a read/write RFID device for industrial application, operationg at 13.56 MHz, that communicates with a ‘host’ system (typically a PC or a PLC) through a RS232/RS485 serial line and acts as a joint through a set of commands between the host system and rfid tags (or transponders) presents near the antenna. The same 'master/slave' protocol is used for the communication between the host system (‘master’) and the reader (‘slave’), independently of the kind of connection (point to point, multidrop net). Through these communication channels, it is also possible to configure the functional parameters and to upgrade the firmware. For the
KIT33039 the reader works with a dedicated external rf antenna. The reader
is equipped with useful removable screw terminal blocks in order to facilitate the electrical wiring in order to allow an easy installation.
2. Technical specifications
Power supply 10Vdc … 27Vdc Current consumption Max 100mA @ 12 Vdc Operating frequency 13.56MHz ± 7kHz Supported tags ICODE2 (Philips)
TAG-IT HF-I (TI) EM4135 (MEM) LRI 64 (ST) LRI 512 (ST)
MB89R118 (FUJITSU) Antenna dedicated external Communication interface RS232 / RS485 Signalling 3 leds, buzzer Operating temperature 0°C … +55°C Connections Removable screw terminal blocks
(cable section: 0.5 ... 1.5mm2)
‘KIT33039’ manual - Rev. 1 Pag 6 of 22
SOLTEC
Manufacturer
Part
Standard
User memory
Notes
Soluzioni Tecnologiche S.r.l.
3. Operating features
Features of the supported transponders:
Philips SL2 IC S20 15693 -2 -3 896 bits (28x32)
à 112 bytes
TI TAG-IT HF-I 15693 -2 -3 2048 bits (64x32)
à 256 bytes
MEM EM4135 15693 -2 -3 2432 bits (38x64)
à 304 bytes
STM LRI 64 15693 -2 -3 - LRI 64
STM LRI 512 15693 -2 -3 512 bits (16x32)
à 64 bytes
FUJITSU MB89R118 15693 –2-3 16000 bits
(250x64) à 2000 bytes
Working description: The version ‘R’ of the reader’s firmware is characterised by the coexistence of
2 ‘parallel’ and asynchronous activities: the transponder identification (UID code of ISO 15693 transponders) and the communication with the ‘host’ system. The ‘continuous’ identification activity, based on an anticollision loop sequence (max 16 transponders can be detected and identified), interacts with the communication activity through a buffer that contains the UID code of the last identified transponders. Due to synchronization and filtering reasons, the buffer is handled by a parameter defined as ‘hold time’ (fixed value of 1 second) and allows to extend ‘artificially’ the presence of the transponders after they leave the antenna’s influence area (the hold time is applied individually for each present transponder); this behaviour is observable looking at the yellow led status that is ‘on’ indicating the presence of transponder/s. Through the command ‘inventory’ it is possible to get the data contained in the buffer.
The reader allows the execution of ‘on request’ functions. During the execution of these functions, the ‘continuous’ identification activity will be suspended temporarily. The involved commands concern read/write specific activities relative to the supported transponders.
ICODE2 UID 64 bits
TAG-IT HF-I UID 64 bits
EM4135 UID 64 bits
UID 64 bits 56 bits OTP
LRI 512 UID 64 bits
MB89R118 UID 64 bits
‘KIT33039’ manual - Rev. 1 Pag 7 of 22