Solo 454, 456, 456 SW, 457, 454HD Operator's Manual

...
US9456702 (04-08)
Operator’s Manual & Parts List
Compression Sprayers: 454, 456, 456 SW, 457, 454HD, 456HD, 457HD, 454V, 456V, 457V, 407CI
STOP!
If you are missing parts, instructions or have questions, DO NOT take this unit back to the store. Call 1-800-SOLO-INC. Solo will send the missing parts/information to you promptly.
WARRANTY:
Solo model 454, 456, 456 SW & 457 sprayers are covered by Solo’s 5-YEAR LIMITED WARRANTY. Solo manufactured parts which fail due to defective material or workmanship will be repaired or replaced without charge. See page 6 for full details.
SAFETY PRECAUTIONS:
Do not exceed 45 psi pressure.
• Do not fill with, use or spray flammable materials.
• Do not use gasoline, acid, caustic or potentially injurious chemicals.
At the time of manufacture of this sprayer, we are not aware of any approved plant protection chemicals which
• would adversely affect this sprayer when applied in their usual concentration.
Observe the recommendations of the chemical manufacturer.
• Prior to removing any part of the sprayer pull the pressure relief valve to release any pressure in the tank.
• Wear rubber gloves, safety goggles and appropriate protective clothing.
• After pumping be sure handle is in the locked down position.
Individuals should be trained in the proper use of this sprayer. Where training is not available, individuals
• should study and follow the procedures detailed in this manual. Do not use acetone based chemicals.
WARNING:
Chemicals can be harmful to individuals and the environment if improperly used. In addition, some chemicals are caustic, corrosive, or poisonous and should be avoided. Read warnings and chemical manufacturer’s instructions. Solo high density polyethylene sprayers are fitted with Viton® seals which are resistant to a wide variety of agricultural, industrial and household chemicals; however, care should be exercised to ensure that sprayer components are clean, functioning properly, and in a good state of repair before and during use. If in doubt about a particular chemical, check with manufacturer. If you suspect or observe indications that the material may be unsafe in a Solo sprayer... STOP! Do Not Use or Apply Chemical. ALWAYS WEAR RUBBER GLOVES, SAFETY GOGGLES AND APPROPRIATE PROTECTIVE CLOTHING.
Read and follow operating instructions.
• Do not fill sprayer over maximum fill mark. Releasing pressure in an overfill condition can cause harmful venting of sprayer contents.
• Relieve pressure only with sprayer upright and while standing on the side of the sprayer opposite the pressure relief valve. Venting
• of sprayer contents can occur if liquid is over bottom of relief valve. CAUTION: To prevent injury from ejected pump assembly and/or solution, never stand with face or body over the top of the tank
• when pumping, or loosening pump. Do not modify sprayer or pressure relief valve.
• Never spray in the direction of humans, animals or property which might be injured or
• damaged by spray formula. Do not use disinfectants, solvents or impregnating agents unless first tested to ensure
• they are not harmful to the environment and sprayer. Do not use liquids with a temperature above 120°F (45°C).
• Remember that a sprayer with liquid is a significant amount of weight (8 lbs. per
• gallon). Use caution when bending, leaning or walking. Bend only at the knees and support yourself as required to ensure personal safety. Do not inflate sprayer without liquid in the tank.
• Do not climb on ladders, trees or other unsteady or potentially unsafe structures.
ASSEMBLY INSTRUCTIONS FOR WAND
1. Ensure that the O-ring is on the non-threaded end of the wand.
2. Insert the non-threaded end of the wand into the O-ring into the open end of the shut-
off valve.
3. Tighten the screw cap.
Optional Pressure Gauge Mounts Here
O-Ring
Shut-Off Valve
year warranty
Screw Cap
Wand
Install Wand Here
CUSTOMER SERVICE COMMITMENT FROM SOLO’S SERVICE DEPARTMENT
In the event the sprayer you have purchased has missing or damaged parts, please call 1-800-765-6462, 9:00 AM—5:00 PM EST.
In order to assist your service representative, please have the following information available: sprayer model number, part description
and part number. A parts list is included in your operator’s manual.
Solo is committed to your satisfaction and is continuing its efforts to earn your future business.
Visit us on the web at www.solousa.com
Troubleshooting and parts ordering available online.
USING THE ADJUSTABLE NOZZLE
To change the spraying pattern, first make sure the retaining nut (2) is screwed tight to the elbow (5). If it is not tight, the nozzle cap (1) and nozzle body (3) will rotate inside the retaining nut and the nozzle will not adjust. For a straight stream pattern, rotate the nozzle cap outward. For a hollow cone pattern, rotate the nozzle cap inward towards the retaining nut. If it becomes difficult to rotate the nozzle cap, remove the nozzle cap from the nozzle body and lubricate the O-ring on the nozzle body with a non-water soluble grease*.
4. Filter with gasket
1. Nozzle cap
2. Retaining nut
3. Nozzle body
5. Elbow
CLEANING:
Carefully clean sprayer after every use.
Pour or spray all remaining chemical out of sprayer.
Pour a small amount of water for water soluble chemicals, or mineral spirits for oil-based chemicals, into the tank.
Pressurize and spray through system until all liquid is gone.
Repeat process with warm soapy water.
Repeat process with warm clear water.
Use an absorbent cloth to dry all internal surfaces.
Follow the recommendations of the chemical manufacturer for disposing of waste water and chemicals.
Do not use aggressive or abrasive cleaning agents.
REMOVING ADJUSTABLE NOZZLE
Unscrew the nozzle cap (1) from the nozzle body (3). This is best accomplished while the retaining nut (2) is securely fastened to the elbow (5). Next, unscrew the retaining nut (2). Push the nozzle body (3) out of the retaining nut (2). The filter (4) will come out with the body. To re-install the nozzle, reverse the above instructions.
OPERATION:
Before using sprayer with chemicals, fill sprayer with fresh
• water to assure that you have it properly assembled; pressurize and then practice spraying. When thoroughly familiar with sprayer operation, follow normal operating procedures. Turn pump handle counter clockwise to remove pump.
• Fill tank with premixed formula up to desired level. (Do not
exceed maximum fill mark.) Observe recommendations of chemical manufacturer. Tighten cap and pump assembly for a good seal.
• Pump to a maximum 45 psi or 3 bar pressure. The valve
• stem on the pressure relief valve will rise up to vent excess pressure over 45 psi. Start or stop spraying by squeezing or releasing the lever on
• the shut-off valve (3). The spray pressure can be monitored with an optional pressure gauge. Prior to every removal of pump (1), release pressure first by
• pulling up on the pressure relief valve stem (2).
MAINTENANCE:
Prior to storage, empty, clean and dry sprayer.
• Always store the sprayer in a dry area, protected from
• freezing, heat and sunlight. Lubricate O-ring in pressure relief valve with non-water
• soluble grease* on a regular basis.
Disassembly: Unscrew pressure relief valve from tank and pull the valve body out of the screw cap. Clean, lubricate, and replace.
Pump Maintenance: Pump pressure sealing is accomplished
with an O-ring (5) on the pump piston (4) which moves within the cylinder (3). Periodically this O-ring should be greased with a non-water soluble grease*. If worn, it should be replaced. A small umbrella valve at the bottom of the cylinder prevents the formula from entering the cylinder. Keep these parts clean and replace if worn.
Disassembly: Unscrew pump assembly from tank. Carefully remove umbrella valve (6) from the bottom of cylinder (3). While holding cylinder firmly with one hand and the handle of the pump piston (4) firmly in the other, with the piston fully inserted in the cylinder, pull back on the piston quickly and forcefully. To re-assemble, place the piston assembly back into cylinder, place heel of hands on opposite sides of the tank cap, while keeping cylinder in place with fingers, tap bottom of cylinder against a flat padded surface. Assembly will lock into place.
3
1
6
2
Tank Cap: A small amount of non-water soluble grease*
on tank cap threads and both sides of the gasket eases tightening and loosening.
Regular Inspection: Inspect and replace worn or damaged
parts promptly. Pay particular attention to tank cap gasket, pressure relief valve and seal, inflation valve (if fitted), umbrella valve O-rings and seals throughout sprayer. Regular lubrication of O-rings and seals is recommended.
2
* Solo Superior Grease or petroleum jelly work well.
OPERATING FEATURES:
Nozzles - Your Solo sprayer is standard with nozzle arrangements which provide a variety of spray patterns.
Item Application Part #
Flat spray nozzle Row treatment 4074263
Jet stream nozzle Spot & longer range 4074755 Plastic adjustable Spot, shrubs & bushes
Item Application Part #
Jet stream nozzle Shrubs and bushes 4074755 and swirl plate = hollow cone
4900527
Spray tips should be assembled as follows for desired spray patterns.
SPRAY TIP ASSEMBLY
1. Flat spray nozzle 5. Nozzle cap
2. Filter 6. Nozzle body
3. Jet cap 7. Brass adj. nozzle*
4. Swirl plate 8. Nozzle retaining nut *Brass adjustable nozzle is not a standard item on all Solo sprayers.
No-drip-check valve replaces # 2 on heavy-duty models
Flat spray Hollow
cone spray
In the best interest of continued technological progress, we reserve the right to change design and configuration of any product without prior or other notice. Therefore, please note that text and illustrations of this manual are not to be considered binding and do not constitute a basis for legal or other claims.
WILL THE PLASTIC MATERIAL LAST?
Only high-grade polyethylene is used. The material is chosen for high molecular weight, high-impact strength, and excellent resistance to chemicals and stress. Ultraviolet inhibitors are used in the material to reduce deterioration caused by sunlight.
WHAT SPRAY NOZZLE SHOULD I USE?
A flat spray nozzle is supplied for spraying paths, garden beds, and general area spraying. A cone nozzle is also supplied for spot spraying and for the treatment of bushes and small trees. For spot spraying, simply remove swirl plate from behind nozzle tip. Save the swirl plate for future use.
Brass
adjustable
nozzle*
Jet stream Plastic
adjustable
nozzle
Available as an option is a reflux filter with a built-in check
HOW HEAVY IS THE UNIT?
Compression sprayers weigh approximately 5 1/2 lbs.
valve (27 00 316) which opens at 5 psi and closes at 4 psi. This virtually eliminates the dripping of fluid still contained in the spray wand. A wide selection of nozzles such as
CAN I USE WEED KILLER AND INSECTICIDE IN
THE SAME SPRAYER?
In theory you can, if the sprayer is thoroughly cleaned out with a bleach water solution of 1:25. In practice, the use of both types of chemicals in the same unit is not recommended as the risk to plants can be high. Use caution when handling any type of chemicals and when cleaning your sprayer. Do not mix cleaning agents.
deflector, adjustable, and anti-drift nozzles are available.
CAN I DO SPOT SPRAYING?
The shut-off valve on the Solo sprayer is well suited for spot spraying. It’s almost effortless! The shut-off valve handle incorporates a clip which holds the valve open for area spraying without tiring the operator’s hand. A pressure gauge may be added with increments from 0 to 6 Bar (0-90 psi).