Sollatek PowerBack PB1000S, PowerBack PB2000S Installation And Operation Manual

INSTALLATION AND OPERATION MANUAL
PowerBack
PB1000S/PB2000S
1
SAFETY INSTRUCTIONS
Before using the product, please read carefully the warning messages and instructions on labels and user manual of this product and other components connected to the product.
The product is designed to be connected with lead-acid battery only. Do not connect the product with other types of batteries.
In the event flooded batteries are used, regular maintenance on the battery shall be performed.
The product is design for indoor installation. Please do not expose the product to direct sunlight, rainfall, or snow.
Before performing any maintenance on the product, please disconnect all power sources (AC mains, batteries, solar panel) to avoid the risk of electrical shock.
Do not attempt to disassemble or repair the product. Only authorized personnel is allowed to perform repair.
While performing maintenance or cleaning (especially on the batteries where hazardous liquid might be touched), it’s recommended to wear necessary personal protections (e.g. gloves and goggle)
The product and external batteries shall not be installed anywhere near smoke, spark, and flame.
In the event a generator with auto-start function is connected with the product, before performing maintenance or cleaning.
2
SCOPE OF WARRANTY
The product comes with a standard 1-year warranty. This warranty includes all defects of design, components and manufacturing. The Warranty is void and does not cover any defects or damages caused by in any of the following circumstances:
Seal on the product is broken The product has been misused, neglected, or abused Improper transportation and delivery The product has been used or stored in conditions outside its electrical
or environmental specifications
The product has been used for purposes other than for which it was
designed
The product has been used outside its stated specifications, operating
parameters and application
Acts of third parties, atmospheric discharges, excess voltage, chemical
influences, natural wear and tear and for loss and damage in transit
Improper testing, operation, maintenance, adjustment, repair, or any
modification of any kind not authorized in writing by the supplier
The product has been connected to other equipment with which it is not
compatible
Use and application beyond the definition in this manual Application beyond the scope of applicable safety standards or grid
codes
Acts of nature such as lighting, fire, storm, flood, vandalism and etc.
The right to repair and/or replace the defective product is at the supplier’s sale discretion. Any warranty claim shall be asserted in writing to the supplier within 5 working days after notice of product failure. The supplier is not responsible for damages beyond the scope of this warranty.
3
TABLE OF CONTENT
PRODUCT OVERVIEW ...................................................................................... 4
1.1 Product Outlook .................................................................................... 5
1.2 Typical Application ................................................................................ 8
INSTALLATION ................................................................................................. 9
2.1 Safety Clearance .................................................................................... 9
2.2 Mounting Inverter on the Wall ............................................................. 9
2.3 Batteries ................................................................................................ 9
2.4 PV (solar) string ................................................................................... 11
2.5 Connect AC Input Cables and Loads ................................................... 12
2.6 AC Input Voltage Range Selector ........................................................ 12
OPERATION ................................................................................................... 13
3.1 Standby Charging Mode ...................................................................... 13
3.2 Operation Modes (after powered on) ................................................ 14
3.3 Priority Setting Switch ......................................................................... 15
3.4 Fault Mode .......................................................................................... 16
3.5 LCD Setting .......................................................................................... 16
SPECIFICATION .............................................................................................. 20
TROUBLESHOOTING ...................................................................................... 21
Alarm Behavior Table .................................................................................... 22
APPENDIX A ................................................................................................... 23
APPENDIX B ................................................................................................... 26
4
PRODUCT OVERVIEW
This is a DC-to-AC inverter with integrated solar battery charger, which can be used as a long run-time UPS (Uninterruptible Power Supply), an energy-saving solution or an automotive inverter (hereinafter referred to as “inverter”).
The inverter accepts input power source from AC mains (utility), battery, and PV (solar) string and switches between various operation modes automatically depending on the operational conditions.
When used as an UPS, battery or PV (solar) string act as back-up power source to supply loads during the outage of AC mains.
When used as an energy-saving device, the PV (solar) string can be set as priority to supply the loads without consuming the power from AC mains, as long as sufficient sunlight is present.
The battery can be charged by both AC mains and PV (solar) string with intelligent charging control.
Key features:
Automatic line-to-battery switchover Built-in enhanced AC chargerBuilt-in solar charger controller Configurable output source priority, charger source priority, charger current and
so on
High efficient DC-to-AC conversion with minimized energy loss Rack design & wall-mounted design for flexible installation Intelligent 3-stage charger control for efficient charging and preventing
overcharge
Auto restart upon AC recovery User-friendly LCD and LED indications with setting function
Smart temperature compensation technology to extend battery life
Multiple protections: low battery alarm, low battery shutdown, over charger
protection, overload protection, over temperature protection, short circuit
protection
5
1.1 Product Outlook
Front Panel
Rear Panel
PV Input terminals
AC output receptacle
AC input receptacle
Battery terminals
DC Fan
6
LCD Display
LCD displays the power flow and input/output readings in a visualized graphic
design which allows the user to understand the operation status easily. The
backlight of LCD remains on whenever the inverter is working (including Standby
Charging Mode and Fault Mode).
Icon
Description
This icon is showed when AC input (from AC mains or generator) presents.
If unit is on wide mode, “WIDE” will be lighted, else “NARROW” will be lighted.
This icon is showed when PV (solar) system presents.
The icon indicates level of remaining battery capacity
The icon indicates battery flow way.
If unit is on CC & CV charging stages, “FAST” will be lighted.
The icon indicates output load level. If unit work on bypass mode, “BYPASS” will be lighted.
Indicate PV input voltage. PV input current, AC input voltage, Battery voltage.
Indicate output voltage, output frequency, load percentage, load VA value, load watt value.
7
The icon indicates unit is on LCD setting mode.
The icon indicates unit is on alarm mode or fault mode.
When unit is on LCD setting mode, it indicates program code.
When unit is on fault mode, it indicates the fault code which can be referred to specific fault event (please refer to Section “Troubleshooting”).
LED Indicators
The operation mode of the inverter can be easily told by LED indicators. Please see the table below for details.
LED indicators
Information
Green
Line Mode 1
(charge current >3A)
Green flashing every 2 seconds
Line Mode 2
(charge current3A)
Green solid lighting
Off-charge mode
Green flashing as cycle:
0.5s On 0.5s Off 0.5s On 4s Off
Yellow
Battery mode
Yellow solid lighting
Red
Overload
Red flashing every 0.5 second
Fault
Red lighting
8
Function Keys
Function Keys
Description
To power on/off
To enter the setting mode or exit setting mode
To go to the next selection page
To confirm the selection in setting mode
1.2 Typical Application
A typical application diagram for home and office applications is as shown below. The inverter can accept AC input from AC mains, and is capable of supply various loads such as fluorescent lamp, fan.