Solid State Logic Alpha Channel Installation Guide

EN
Solid State Logic
S O U N D
||
V I S I O N
DE
AAllpphhaa CChhaannnneel
Installation Guide
Installationsanleitung
Manuel d’Installation
Manual de Instalación
Guida di Installazione
l
FR
ES
IT
82S6AL010A
CCoonntteenntts
English 1
Deutsch 9
Francais 17
Espanol 25
Italiano 33
s
EN
DE
FR
ES
IT
Safety and Installation Considerations
This section contains definitions, warnings, and practical information to ensure a safe working environment.
Please take time to read this section before installing or using this unit. Please do not dispose of these instructions.
General Safety
• Read these instructions.
• Keep these instructions.
• Heed all warnings.
• Follow all instructions.
• Do not use this apparatus near water.
• Do not expose this apparatus to rain or moisture.
• Clean only with dry cloth.
• Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
• Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers) that produce heat.
• There are no user-adjustments, or user-servicable items, inside this apparatus. Do not remove the covers of this apparatus; doing so will invalidate your warranty.
• Refer all servicing to qualified personnel. Servicing is required when the power supply has been damaged in any way, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally or has been dropped.
• Adjustments or alterations to this apparatus may affect the performance such that safety and/or international compliance standards may no longer be met.
Power Safety
• This apparatus is fitted with a universal power supply, approved and certified for operation in this apparatus. There are no user-replaceable fuses.
• A power cord is supplied with this unit. Alternative power cords may be used if rated 2.5A or above and fitted with a 3-pin IEC320 connector.
• If an extension power cable or adaptor is used, ensure that the total power rating of the power cable and/or adaptor is not exceeded.
• The power socket used for this apparatus should be located nearby and be easily accessible.
• Unplug this apparatus during an electrical storm or when unused for long periods of time.
Installation Notes
• When installing this apparatus, place the apparatus on a secure level surface.
• Ensure that no strain is placed on the cables connecting to this apparatus. Ensure also that such cables are not placed where they can be stepped on, pulled or tripped over.
• Do not operate this apparatus whilst it is covered or boxed in any way.
• Do not operate this unit with the covers removed. Performance may be adversely affected.
EN
DE
FR
ES
IT
1
1. Un-pack
5A
AAllpphhaa CChhaannnneel
l
Installation Guide
Installationsanleitung
Manuel d’Installation
Manual de Instalación
Guida di Installazione
82S6AL010A
EN
DE
FR
ES
IT
Solid State Logic
S O U N D||V I S I O N
AL P H A
CH A N N E L
Your Alpha Channel box should contain the following:
The Alpha Channel Unit
or or
2
1 x Power Cord *
* The cord supplied will be correct for the territory
where Alpha Channel is purchased
Installation Guide
(this document)
2. Connect
INSERT
MANUFACTURED IN U.K.
LINK
IN OUT
SPDIF
ANALOGUE
OUT
SEND
RETURN
~
50/60Hz
100 - 240VAC
0.4 - 0.2A
POWER
RISK OF ELECTRIC SHOCK
This equipment must be earthed. Refer to manual for installation instructions. CAUTION! Disconnect all power sources before removing any panel(s). No user-serviceable parts inside - to be serviced only by qualified personnel. WARNING! Unearthed parts may be present inside enclosure. Check for hazardous voltages before touching. Do not expose to rain or moisture
DO NOT OPEN
CAUTION
Solid State Logic - Oxford - England
ALPHA Channel
Part no. 629999XA Serial No
1
2345
Lite Limit Link (daisy-chain to other Alpha Channel units)
Linked units have the same degree of ‘limiting’; useful for stereo signals
Insert Send/Return*
Balanced, level relative to output: 0dB (Lite Limit out)
+12dB (Lite Limit in)
* Only active whilst the Insert is switched ‘IN’
EN
DE
AC Line Power
100 – 240Vac ~50/60Hz
Alpha Channel’s SPDIF Out will run at 44.1kHz unless
an external SPDIF Sync is provided (32kHz ~ 108kHz).
Left stream: Main Analogue Output (0dB FS = +24dBu) Right stream: Pre- Insert Send signal
Connections (Front Panel – see overleaf)
Microphone 3-pin XLR-F Instrument ¼" Mono Jack
Pin 1 0V Tip Signal
Pin 2 +ve Sleeve 0V
Pin 3 –ve
SPDIF In
SPDIF Out
Analogue Output
Balanced, max. output: +24dBu = 0dB FS
Connections (Rear Panel)
Phono ¼" Stereo Jack
Tip Signal +ve
Ring n/a –ve
Sleeve 0V 0V
FR
ES
IT
3
3. Play!
Input Switches
Switches Mic Input impedence from 1kΩ to 10kΩ.
Hi Z
Use with PAD for Line Level inputs.
PAD Fixed 20dB attenuation for high level signals.
Glows ‘red’ when input is in ‘overload’ condition.
48V Switches +48V (‘phantom power’) to the Mic Input.
Always switch OFF before connecting/dis-connecting microphone.
Ø Inverts the phase of the input signal.
Power/Standby
Bright when unit is on,
dim when in standby
Mono ¼" Jack for high impedence Instrument Input
Mic/Instrument
Balanced XLR for Mic Input,
Insert Selection
IN
Routes signal out of the Insert Send to be returned through the Insert Return (pre- EQ)
POST EQ Places the Insert Send and Return after the EQ SUM Mixes the Send signal with the Return signal
Input Gain
Provides +20dB to +75dB gain
Variable Harmonic Drive™
Adds level dependent colouration; initially warm
nd
harmonic then more aggressive 3rdharmonic
2
High Pass Filter
40Hz (–3dB) 80Hz (–3dB) 120Hz (–3dB)
4
ADC Lock
Indicates that a valid SPDIF signal is present on the SPDIF IN socket
on the rear of the unit and that the ADC is locked to this signal
Low Frequency: Switchable ‘shelving’ or ‘bell’ curves
EQ IN
Select between a ‘shelving’ or a ‘bell’ curve:
Mid Frequency: Parametric with adjustable frequency and ‘Q’ High Frequency: Fixed ‘shelving’ curve
LF Bell
Shelving’Bell’
3-Band EQ
Output Gain
Provides ±20dB of adjustment
Provides a non-intrusive signal limiter ahead of the ADC. When switched in, the pre- Insert Send level will drop by 12dB to enable headroom to be retained under limiting conditions. The switch will glow ‘green’ whilst the limiter is in-active, and change progressively through ‘orange’ to ‘red’ as more limiting is applied.
Output Meter
Measures level before the ADC,
‘0’ indicates 0dB FS
Lite Limit
EN
DE
FR
ES
IT
5
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC
T
ested To Comply
with FCC Standards
FOR HOME OR OFFICE USE
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/ TV technician for help.
Instructions for Disposal of WEEE by Users in the European Union
The symbol shown here is on the product or on its packaging, which indicates that this product must not be disposed of with other waste. Instead, it is the user’s responsibility to dispose of their waste equipment by handing it over to a designated collection point for recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or where you purchased the product.
Standards Conformance
This apparatus fully conforms with the current protection requirements of the European community council directives on EMC and LVD.
Warranty
This product is warranted against failure resulting from faulty materials or workmanship for a period of 12 months from date of purchase.
In Warranty Repairs
In the event of a fault arising during the warranty period, please contact your local dealer or distributor who will arrange either for repair or replacement as appropriate (a list of dealers and distributors can be found on the Solid State Logic website: www.solid-state-logic.com repair by Solid State Logic unless accompanied by a valid RMA number, obtainable from Solid State Logic prior to shipping. All units should be shipped to Solid State Logic in their original packaging. Solid State Logic cannot be held responsible for any damage caused by shipping units in other packaging. In such cases Solid State Logic will return the unit in a suitable box, which you will be charged for. Do not include the power cable, manual or any other items – Solid State Logic can not guarantee to return them to you. Please also note that warranty returns will only be accepted as such if accompanied by the original receipt or
other proof of purchase.
Out of Warranty Repairs
In the event of a fault arising after the warranty period has expired, return the unit in its original packaging to your local distributor for shipment to Solid State Logic. You will be charged for the time spent on the repair (at Solid State Logic's current repair rate) plus the cost of parts and shipping. Note that no units will be accepted for repair unless accompanied by a valid RMA number, obtainable from Solid State Logic prior to shipping.
). Note that no units will be accepted for
6
Specifications
Physical *
Depth 230mm / 9" casing only Height 44.5mm / 1.75" (1 RU) Width 438mm / 17.25" casing only
482mm / 19" inc’ rack ears Weight 3.0kg / 7 pounds Power < 20 Watts Boxed size 320mm x 550mm x 80mm
12.75" x 21.75" x 3.25"
Boxed weight 3.5kg / 8 pounds
* All values are approximate
Environmental
Temperature Operating: +5 to 30 deg. C
Non-operating: –20 to 50 deg. C Max. gradient: 15 deg. C/hour
Relative Operating: 20 to 80 % Humidity Non-operating: 5 to 90 %
Max. wet bulb: 29 deg. C (non-condensing)
Vibration Operating: < 0.2 G (3 – 100Hz)
Non-operating, power off: < 0.4 G (3 – 100Hz)
Shock Operating: < 2 G (10ms max.)
Non-operating: < 10 G (10ms max.)
Altitude Operating: 0 to 3000m (above sea level) Non-operating: 0 to 12000m
Connections
Power IEC320 3-pin connector, 100 – 240 Vac, 50 – 60 Hz
Analogue I/O
Microphone Balanced, 3-pin XLR-F, Zin = 1kΩ (10kΩ for Hi Z) Instrument Un-balanced, ¼" Mono Jack, Zin = 1MΩ Output Balanced, ¼" Stereo Jack, Zo = 40Ω Insert Send Balanced, ¼" Stereo Jack, Zo = 40Ω Insert Return Balanced, ¼" Stereo Jack, Zin = 10kΩ Link (2 of) RCA phono, limiter sidechain control voltage (dc.)
Digital I/O
SPDIF In RCA phono, 1V pk-pk, Zin = 75Ω, SPDIF format.
The ADC will lock to this signal if present.
SPDIF Out RCA phono, 1V pk-pk, Zo = 75Ω, SPDIF 24bit format.
Synchronised to SPDIF In, else free-runs at 44.1kHz.
EN
DE
FR
ES
IT
7
8
Sicherheits- und Installationsanweisungen
Dieses Kapitel enthält Definitionen, Vorsichtsmassnahmen und praktische Informationen um ein sicheres Arbeitsumfeld zu garantieren.
Bitte nehmen Sie sich die Zeit, dieses Kapitel zu lesen, bevor Sie das Gerät installieren und benutzen. Bitte bewahren Sie diese Anweisungen auf.
Allgemeine Sicherheit
• Lesen Sie diese Anweisungen.
• Behalten Sie diese Anweisungen.
• Beachten Sie die Warnungen.
• Folgen Sie sämtlichen Anweisungen.
• Benutzen Sie das Gerät nicht in der Nähe von Wasser.
• Setzen Sie das Gerät keiner Feuchtigkeit oder Regen aus.
• Nur mit trockenem Tuch reinigen.
• Die Lüftungsöffnungen nicht blockieren. Den Herstellerangaben zufolge installieren.
• Nicht in der Nähe von Hitzequellen einbauen, wie Heizungen, Wärmespeichern, Öfen oder anderen Geräten (inkl. Verstärkern) die Hitze erzeugen.
• Es gibt keinerlei Einstellungen oder vom Anwender zu wartende Teile im Inneren des Gerätes. Die Abdeckungen dürfen nicht entfernt werden. Durch das Entfernen selbiger wird die Garantie ungültig.
• Überlassen Sie sämtliche Wartungsarbeiten qualifiziertem Personal. Wartung wird fällig, wenn das Netzteil in irgendeiner Form beschädigt wurde, Flüssigkeit oder Gegenstände ins Innere des Gerätes gelangt sind, das Gerät Feuchtigkeit oder Regen ausgesetzt wurde, nicht normal funktioniert oder heruntergefallen ist.
• Einstellungen oder Änderungen am Gerät können die Leistung derart beeinflussen, dass die Sicherheit und/oder die Konformität mit internationalen Standards nicht mehr erreicht wird.
Sicherheit der Stromzufuhr
• Dieses Gerät ist mit einem Universal Netzteil ausgestattet, geprüft und zugelassen für den Betrieb in diesem Gerät. Es gibt keine durch den Nutzer auszuwechselnde Sicherungen.
• Ein Netzkabel wird mitgeliefert. Andere Netzkabel können eingesetzt werden, wenn sie für 2,5A ausgelegt sind und über einen dreipoligen IEC320 Steckverbinder verfügen.
• Wenn eine Stromverlängerung oder ein Adapter benutzt wird, stellen Sie sicher, dass die zulässige Gesamtlast des Stromkabels oder Adapters nicht überschritten wird.
• Die Steckdose für dieses Gerät sollte in der Nähe und leicht zugänglich sein.
• Während Unwettern oder längerer Nichtbenutzung, den Stecker herausziehen.
Hinweise zur Installation
• Beim Installieren des Gerätes selbiges auf eine sichere, ebene Oberfläche platzieren.
• Sorgen Sie dafür, das kein Zug auf den Anschlusskabeln liegt. Achten Sie ebenfalls darauf, dass die Kabel so liegen, dass niemand darüber stolpern, darauf treten oder daran ziehen kann.
• Benutzen Sie das Gerät nicht, wenn es in einer Verpackung oder zugedeckt ist.
• Benutzen Sie das Gerät nicht mit offenen Abdeckung um die Systemleistung nicht zu beeinträchtigen.
EN
DE
FR
ES
IT
9
1. Un-pack
5A
AAllpphhaa CChhaannnneel
l
Installation Guide
Installationsanleitung
Manuel d’Installation
Manual de Instalación
Guida di Installazione
82S6AL010A
EN
DE
FR
ES
IT
Solid State Logic
S O U N D||V I S I O N
AL P H A
CH A N N E L
Folgendes sollten Sie in der Verpackung finden:
oder oder
Der Alpha Channel
10
1 Netzkabel *
* Das Netzkabel des Lieferumfanges ist passend für
das Gebiet, in dem das Gerät gekauft wurde
Installationsanleitung
(dieses Dokument)
Loading...
+ 30 hidden pages