STEP 2
Attach the SolidDrive mounting bracket to wall studs or ceiling joists
STEP 3
Insert the SolidDrive into the bracket
STEP 4
Make the electrical connections
STEP 5
Apply adhesive to the drywall surface and base of the SolidDrive
STEP 6
EXISTING DRYWALL
Re-install rectangular cutout in wall
STEP 7
Install the new drywall
Place the mounting bracket between the wall studs or ceiling joists and secure with four 1
screw them into the face of each wall stud or ceiling joist (Figure 2). The drywall screws need
Figure 2
SolidDrive
MSK-1
mounting
bracket
attached to
the wall studs
Feed the SolidDrive MSK-1 cable through the round opening in the face of the mounting
bracket. Insert the SolidDrive MSK-1 through the same opening with the oversized
against the bracket face. Align the pre-drilled holes in the mounting base to the threaded
holes in the bracket face (Figure 3). Attach the SolidDrive MSK-1 securely to the mounting
Figure 3
SolidDrive
MSK-1 being
installed into
the mounting
bracket
If possible, position the drywall panel so that the SolidDrive MSK-1 is at the center of the
panel or as far from the edge of the panel as possible. This will allow proper distribution of
sound and the SolidDrive MSK-1 will function with optimum performance. Prior to
mounting, take measurements of the new drywall panel to determine the exact area that
will come in contact with the base of the SolidDrive MSK-1 and spray that area liberally
with the 3M
®
Super 77 contact spray adhesive. Also, liberally spray the surface of the
oversized mounting base of the SolidDrive MSK-1 (masking around the base is highly
recommended to prevent overspray).
Make the electrical connection between the SolidDrive MSK-1 and the speaker cable using
the included Eurostyle connector. Be sure to observe proper polarity when connecting the
SolidDrive MSK-1. NOTE: When installed in Canada, this product must be installed in
accordance with the Canadian Electrical Code, C22.1, Part1.
For re-installing the rectangle drywall panel that was cut out to install the SolidDrive
MSK-1, it is important to create a uniform seal between the cut drywall and the existing
drywall. This will allow proper distribution of sound and the SolidDrive MSK-1 will function
with optimum performance. Apply fast setting joint compound, not vinyl based, in the
space completely with drywall compound then proceed with the normal taping, sanding
Immediately install the new drywall before the spray adhesive sets up (approximately 10
Apply joint compound in the space between the drywall panels and proceed with the
panels will improve the distribution of sound as well as overall sound quality.
Figure 4
By utilizing these basic installation steps, you can install the SolidDrive MSK-1sm on
wood, laminate, composites, and other porous surfaces. The MSK-1sm is commonly used
on desks, conference tables, cabinetry, and other furniture.
INSTALLATION OF SOLIDDRIVE MSK-1sm TO WOOD SURFACES
Figure 1
Mounting the
SolidDrive
MSK-1sm to a
table.
Once you have determined where to mount the SolidDrive MSK-1sm, spray a thin layer of
3M
®
Super 77 adhesive on the bottom of the SolidDrive, then use the appropriate length
wood screws to attach it securely to the surface. The adhesive improves the sonic
transmission between the drive and the surface. The best mounting location is typically
out of sight on the underside or back of desks, counter tops, conference tables, or other
oversized mounting base will hold screws as large as #9. Refer to Step 4 for electrical
connections.
Some installations may require that pilot holes be drilled into the surface material due to
its hardness, especially if larger, coarse thread screws are used.
For installation on glass surfaces, the SolidDrive MSK-1g comes with a VHB double-sided
adhesive disc.
INSTALLATION OF SOLIDDRIVE MSK-1g TO GLASS SURFACES
The SolidDrive MSK-1g should be mounted in an inconspicuous location of the window.
Simply apply the VHB pad that comes with the drive to the base of the drive (the side
opposite the label). Remove one side of the protective layers from the VHB disc and apply
to the base of the MSK-1g. Then remove the other protective layer and apply to glass
surface with moderate pressure. Refer to Step 4 for electrical connections.
When mounting the SolidDrive on the window, keep it about 4 to 6 inches from the window
frame. The SolidDrive MSK-1g will have maximum output with at least 20 square feet of
window surface space.
Figure 1
Mounting the
SolidDrive
MSK-1g to
glass.
+
NOTE: Adhesive is required in addition to the mounting bracket. Failure to apply the
adhesive to both the drywall surface and oversized mounting base will prevent the
system from functioning properly.