4010450
V210127
Air conditioner must be upright for 24 hours prior to operating.
This ensures that the compressor will function as intended.
Model
WS4-06EW-201 6,000 BTU
WS4-08EW-201 8,000 BTU
Electronic Hybrid Air Conditioner
Operating Instructions

Thank you for choosing a Soleus Air Hybrid Air Conditioner. This Owner’s Manual will provide
you with valuable information necessary for the proper care and maintenance of your new product.
Please take a few moments to thoroughly read the instructions and familiarize yourself with all the
operational aspects of your new Soleus Air Window Air Conditioner.
For your own records, please attach a copy of your sales receipt to this manual. Also, write the
store name/location, date purchased, and serial number below:
Store Name: ____________________________________________________
Location: _____________________________________________________
Date Purchased: _________________________________________________
Serial Number (located on back of unit): ______________________________
IMPORTANT INSTRUCTIONS
PURCHASE INFORMATION
Before installing and using your air conditioner, please read this owner’s manual carefully. Store this manual in a
safe place for future reference. Your safety and the safety of others is very important to us. Please pay attention to
all safety messages outlined in this owner’s manual.
WARNING: To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow these basic
precautions:
• Plug into a grounded 3 prong outlet.
• Do not remove the ground prong.
• Do not use a plug adapter.
• Do not use an extension cord.
• Unplug the air conditioner before servicing.
• Use two or more people to move and install the air
conditioner.
This is a safety alert symbol.
This symbol alerts you to potential hazards that can harm you or others or even cause death.
All safety messages will directly follow the safety alert symbol and/or the words “DANGER”
or “WARNING.”
All Safety messages alert you of potential hazards, how to reduce the chance of injury, and what
can happen if instructions are not followed correctly.
Failure to immediately follow these instructions may cause serious injury or
even death.

This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord
and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the
nominal current leakage between the cord shield and either load conductor exceeds a predetermined value.
The cord will remain de-energized until the device has been manually reset. This is intended to reduce the
risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they
must be considered a shock hazard if exposed. The cord shield must not be connected to ground or to any
exposed metal.
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly.
To test:
1. Plug power cord into wall outlet, the LED light will turn on.
2. Press TEST Button, circuit should trip, cutting power to the air conditioner. When this occurs, the LED
light will turn off.
3. Press RESET button to restore power to the unit. Once power is restored, the LED light will turn on
again.
If test button is pressed and unit can still be turned on, current leakage has been detected. Do not use the air
conditioner or attempt to reset the LCDI Plug. Contact Customer Service for troubleshooting recommendations.
WARNING:
1. DO NOT press the TEST button while the air conditioner is operating.
2. The TEST and RESET buttons should not be used as “ON” and “OFF” switches.
3. The cord and plug are not intended to offer protection to externally connected loads or supply circuits.
4. The cord and plug are intended for
indoor use only.
POWER CORD AND PLUG
RESET
TEST
LED LIGHT
Note: Your unit’s power cord may
differ from the one shown.

PACKAGE CONTENTS
Air Conditioner
(2) - Mounting Block
• Hybrid Air Conditioner (1)
• Remote Control (1)
• AAA Battery (2)
• Window Slider Foam (2)
• Mounting Block (2)
• Window Slider Support Bracket (2)
• Pre-installed Adjustable Support Knob (2)
• Top Foam Sealer (1)
• Bubble Level (1)
• Optional Window Security Bracket
- Security Bracket (1) , Type B Screw (1)
• Owner’s Manual (1)
Remote
Control
2 AAA
Batteries
Top Foam
Sealer
Owner’s Manual
(2) - Window Slider Support Bracket
(2) - Window Slider Foam
(1) - Security Bracket
(1) - Type B Screw
(2) - Pre-installed Adjustable Support Knob
Bubble Level

SPECIFICATIONS
• Noise level is measured at a distance of 3.28 ft away from the front of the unit in cooling mode.
• Power consumption is measured when the fan runs at the highest speed setting.
• These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
Model WS4-06EW-201 WS4-08EW-201
Power Supply (Ph/V/Hz) 1/115/60 1/115/60
Rated Cooling Capacity (BTU/h) 6,000 8,000
Cooling Power Input (Watts) 495 667
Rated Current Cooling (Amperage) 4.5 6.5
CEER 12.1 12.0
Noise Level (dB(A)) 38-49 (Indoor) / 51-63 (Outdoor) 38-49 (Indoor) / 51-63 (Outdoor)
Airflow CFM 170/230/270 165/223/264
Dehumidifying Capacity 30 Pints per day 34 Pints per day
Product Dimensions (W” x H” x D”) 18.7” x 15” x 28.9” 18.7” x 15” x 28.9”
Package Dimensions (W” x H” x D”) 20.4” x 17.3” x 30.8” 20.4” x 17.3” x 30.8”
Net/Gross Weight (lbs) 67.7/80 71.2/83
Refrigerant Type R-410A R-410A
Plug Type NEMA 5-15P NEMA 5-15P
FCC Notice
This device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
device generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful
interference to radio or television reception, which can be determined by turning the device off and on, the user is encourag ed
to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the device and receiver
Connect the device into an outlet on a circuit different from that to which the receiver is connected
Consult the dealer or an experienced radio/television technician for help .
Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.

ELECTRICAL SAFETY
WARNING:
grounding prong!!
Power supply cord with 3-prong grounding
plug and current detection device
DISCLAIMER
ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’S MANUAL ARE THE
PRESENATION OF THE MANUFACTURER. NEPO USA HAS NOT CONDUCTED AN INDEPENDENT TEST TO
VERIFY THE INFORMATION AND SPECIFICATIONS PRESENTED HEREWITHIN.