Soleus Air WS2-06E-201, WS2-08E-201, WS2-12E-201, WS2-10E-201 Operating Instructions Manual

V181219
Air conditioner must be upright for 24 hours prior to operating.
This ensures that the compressor will function as intended.
Model
WS2-08E-201 8,000 BTU WS2-10E-201 10,200 BTU WS2-12E-201 12,000 BTU
Electronic Window Air Conditioner Operating Instructions
AIR CONDITIONER
2MF3
File No. SA 12793
Thank you for choosing a Soleus Air Window Air Conditioner. This Owners Manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Soleus Air Window Air Conditioner.
For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date purchased, and serial number below:
Store Name: ____________________________________________________
Location: _____________________________________________________
Date Purchased: _________________________________________________
Serial Number (located on back of unit): ______________________________
IMPORTANT INSTRUCTIONS
PURCHASE INFORMATION
Before installing and using your air conditioner, please read this owners manual carefully. Store this manual in a safe place for future reference. Your safety and the safety of others is very important to us. Please pay attention to all safety messages outlined in this owners manual.
WARNING: To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow these basic precautions:
Plug into a grounded 3 prong outlet.
Do not remove the ground prong.
Do not use a plug adapter.
Do not use an extension cord.
Unplug the air conditioner before servicing.
Use two or more people to move and install the air
conditioner.
This is a safety alert symbol. This symbol alerts you to potential hazards that can harm you or others or even cause death. All safety messages will directly follow the safety alert symbol and/or the words DANGER or WARNING.
All Safety messages alert you of potential hazards, how to reduce the chance of injury, and what can happen if instructions are not followed correctly.
Failure to immediately follow these in­structions may cause serious injury or even death.
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexi­ble cord with no termination on the load side and a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain de-energized until the device has been manually reset. This is intended to reduce the risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must be considered a shock hazard if exposed. The cord shield must not be connected to ground or to any exposed metal.
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:
1. Plug power cord into wall outlet, the LED light will turn on.
2. Press TEST Button, circuit should trip, cutting power to the air conditioner. When this occurs, the LED light will turn off.
3. Press RESET button to restore power to the unit. Once power is restored, the LED light will turn on again.
If test button is pressed and unit can still be turned on, current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Customer Service for troubleshooting recommenda­tions.
WARNING:
1. DO NOT press the TEST button while the air conditioner is operating.
2. The TEST and RESET buttons should not be used as ONand OFFswitches.
3. The cord and plug are not intended to offer protection to externally connected loads or supply circuits.
4. The cord and plug are intended for
indoor use only.
POWER CORD AND PLUG
RESET
TEST
LED LIGHT
Note: Your units power cord may differ from the one shown.
PACKAGE CONTENTS
Top Mounting Rail
Air Conditioner
Side Curtain
Top Mounting Rail
Foam Seal
Insert Strip
Short Screw Long Screw
Sash Lock
Curtain Lock
Window Air Conditioner (1)
Remote Control (1)
AAA Battery (2)
Top Mounting Rail (1)
Insert Strip (1)
Short Screw (8)
Side Curtain (2)
Sash Lock (2)
Foam Seal (1)
Long Screw for Window Locking Bracket & Cur-
tains (12)
Curtain Lock (2)
Owners Manual (1)
Weather Insulation Board (2)
Remote
Control
2 AAA
Batteries
Owners
Manual
Weather Insulation Board
SPECIFICATIONS
Noise level is measured at a distance of 3.28 ft away from the front of the unit in cooling mode.
Power consumption is measured when the fan runs at the highest speed setting.
These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
Model WS2-06E-201 WS2-08E-201
Power Supply (Ph/V/Hz) 1/115/60 1/115/60
Rated Cooling Capacity (BTU/h) 6,200 8,000
Cooling Power Input (Watts) 495 667
Rated Current Cooling (Amperage) 4.3 6.5
CEER 12.1 12
Noise Level dB(A) (L/H) 55/58 58/61
Airflow (H/L) CFM 194/158 264/223
Dehumidifying Capacity 30.48 Pints per day 34.8 Pints per day
Product Dimensions (Wx Hx D”) 18.625” x 12.625” x 15.5” 19” x 14.375” x 19.5”
Package Dimensions (Wx Hx D”) 23” x 15” x 18.625” 22.5” x 17” x 21.5”
Net/Gross Weight (Lbs) 46.3/55.1 57.3/63.9
Refrigerant Type R-410A R-410A
Plug Type NEMA 5-15P NEMA 5-15P
Model WS2-10E-201 WS2-12E-201
Power Supply (Ph/V/Hz) 1/115/60
1/115/60
Rated Cooling Capacity (BTU/h) 10,200 12,000
Cooling Power Input (Watts) 850
1,000
Rated Current Cooling (Amperage) 7.5 8.7
CEER 12 12
Noise Level dB(A) (L/H) 55/59
55/59
Airflow (H/L) CFM 264/223
264/155
Dehumidifying Capacity 43.4 Pints per day 52.3 Pints per day
Product Dimensions (Wx Hx D”) 19” x 14.375” x 21.5” 19” x 14.375” x 21.5”
Package Dimensions (Wx Hx D”) 21.3” x 17.1” x 22.7”
21.3” x 17.1” x 22.7”
Net/Gross Weight (Lbs) 66/72 72.7/77.2
Refrigerant Type R-410A
R-410A
Plug Type NEMA 5-15P NEMA 5-15P
ELECTRICAL SAFETY
WARNING:
grounding prong!!
Power supply cord with 3-prong grounding plug and current detection device
DISCLAIMER
ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USERS MANUAL ARE THE PRESENATION OF THE MANUFACTURER. SOLEUS N.A. HAS NOT CONDUCTED AN INDEPENDENT TEST TO VERIFY THE INFORMATION AND SPECIFICATIONS PRESENTED HEREWITHIN.