Soleus Air WM1-05M-01,WM1-06E-01,WM1-08E-01,WM1-10E-01 Operating Instructions Manual

Model
WM1-05M-01
54,000 BTU
Window Air Conditioner
Operating Instructions
Thank you for choosing a Soleus Air Air Conditioner. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new air conditioner.
For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date purchased, and serial number below:
Store Name: ____________________________________________________
Location: ______________________________________________________
Date Purchased: _________________________________________________
Serial Number (located on back of unit): ______________________________
IMPORT
ANT
SAFETY INSTRUCTIONS
Before installing and using your air conditioner, please read this owner’s manual carefully. Store this manual in a safe place for future reference. Your safety and the safety of others is very important to us. Please pay attention to all safety messages outlined in this owner’s manual.
WARNING: To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow the following basic precautions:
Plug into a grounded 3 prong outlet.
Do not remove the ground prong.
Do not use a plug adapter.
Do not use an extension cord.
Unplug the air conditioner before servicing
Use two or more people to move and install the air
conditioner
This
is a safety alert symbol. This symbol alerts death. All safety message “DANGER” or
“WARNIN
you
to potential hazard
s will di
rectly follow the safety alert symbol and/
G”.
s that can
harm you or others or even cause
or the words
All Safety messages alert you of potential hazards, how to reduce the chance of injury, and what can happen if instructions are not followed correctly.
1
Failure to immediately follow these instructions may cause serious injury or even death.
2
LCDI POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexi­ble cord with no termination on the load side and a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain de-energized until the devise has been manually reset. This is intended to re­duce the risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any exposed metal.
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:
1. Plug power cord into wall outlet. The LED light will turn on.
2. Press TEST Button, circuit should trip, cutting power to the air conditioner. When this occurs,
3. Press RESET button to restore power to the machine. Once power is restored, the LED light
will turn on again.
If test button is pressed and unit can still be turned on, current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Customer Service for troubleshooting recommendations.
WARNING:
1. DO NOT press the TEST button while the air conditioner is operating.
2. The TEST and RESET buttons should not be used as ONand OFFswitches.
3. The cord and plug are not intended to offer protection to externally connected loads or supply circuits.
4. The cord and plug are intended for indoor use only.
LED LIGHT
the LED light will turn off.
Note: Your units power cord and plug may differ from the one shown.
PART LIST
Part List:
Window Air Conditioner (1) Top Mounting Rail (1) Insert Strip (1) Short Screw (8) Curtain (2)
Sash Lock (2) Foam Seal (1) Long Screw for Window Locking Bracket & Curtains (12) Curtain Lock (2) Owner’s Manual (1) Weather Insulation Board (2)
3
SPECIFICATIONS
Noise level is measured at a distance of 3.28 ft away from the front of the unit in cooling mode.
Power consumption is measured when the fan runs at the highest speed setting.
These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
Power Supply (Ph/V/Hz) 1/115/60 1/115/60
Rated Cooling Capacity (BTU/h) 5,400 6,400
Cooling Power Input (Watts) 473 495
Rated Current Cooling (Amperage) 4.7 4.3
Model WM1-05M-01 WM1-06E-01
EER 11.2 12.1
Noise Level dB(A) (L/H) 55/58 55/58
Airflow (H/L) CFM 330/270 330/300/270
Dehumidifying Capacity 22 Pints per day 31 Pints per day
Product Dimensions (W” x H” x D”) 18.625 x 12.625 x 15.5
Package Dimensions (W” x H” x D”) 23 x 15 x 18.625 23 x 18.625 x 15
Net/Gross Weight (Lbs) 46/55 46/55
Refrigerant Type R-410A R-410A
Plug Type NEMA 5-15P NEMA 5-15P
4