Thank you for choosing a Soleus Air fueled by TCL Portable Air Conditioner. This owner’s man-
ual will provide you with valuable information necessary for the proper care and maintenance of
your new product. Please take a few moments to thoroughly read the instructions and familiarize
yourself with all the operational aspects of your new Soleus Air fueled by TCL Portable Air Conditioner.
For your own records, please attach a copy of your sales receipt to this manual. Also, write the
store name/location, date purchased, and serial number below:
Store Name: ____________________________________________________
POWER SOURCE 115 V / 60 HZ 115 V / 60 HZ 115 V / 60 HZ
SOUND PRESSURE LEVEL 53 dB(A) 54 dB(A) 53 dB(A)
PRODUCT WEIGHT 59.5 Lbs 62.8 Lbs 60.6 Lbs
OPERATING
TEMPERATURE
PRODUCT DIMENSIONS
REFRIGERANT R-410A R-410A R-410A
70℉-95℉ 70℉-95℉ 70℉-95℉
10.625” W×18.875” D
×27.375” H
10.625” W×18.875” D
3
×27.375” H
10.625” W×18.875” D
×27.375” H
LCDI POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord
and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the
nominal current leakage between the cord shield and either load conductor exceeds a predetermined value.
The cord will remain de-energized until the devise has been manually reset. This is intended to reduce the
risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they
must be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any
exposed metal.
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:
1. Plug power cord into wall outlet
2. Press TEST Button, circuit should trip, cutting power to the air conditioner
3. Press RESET button for use
If test button is pressed and unit can still be turned on, current leakage has been detected. Do not use the air
conditioner or attempt to reset the LCDI Plug. Contact Soleus Home Comfort Customer Service for troubleshooting recommendations.
Note: Your unit’s power cord may differ from the one shown.
WARNING:
1. DO NOT press the TEST button while the air conditioner is operating.
2. The TEST and RESET buttons should not be used as “ON” and “OFF” switches.
3. The cord and plug are not intended to offer protection to externally connected loads or supply circuits.
4. The cord and plug are intended for indoor use only.
RESET
TEST
4
ALTERNATIVE LCDI POWER CORD AND PLUG
WITH LED LIGHT
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord
and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the
nominal current leakage between the cord shield and either load conductor exceeds a predetermined value.
The cord will remain de-energized until the devise has been manually
reset. This is intended to reduce the
risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they
must be considered a shock hazards if exposed. The cord shield must not be connected to ground or to
any exposed metal.
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning prope
rly. To test:
1. Plug power cord into wall outlet. The LED light will turn on.
2. Press TEST Button, circuit should trip, cutting power to the air conditioner. When this occurs,the LED light will turn off.
3. Press RESET button to restore power to the machine. Once power is restored, the LED light
will turn on again.
If test button is pressed and unit can still be turned on, current leakage
air conditioner or attempt to reset the LCDI P
lug. Contact Soleus Home Comfort for troubleshooting
has been detected. Do not use the
recommendations.
LED LIGHT
Note: Your unit's power cord and plug may differ from the one shown.
WARNING:
1. DO NOT press the TEST button while the air conditioner is operating.
2. The TEST and RESET buttons should not be used as “ON” and “OFF” switches.
3. The cord and plug are not intended to offer protection to externally connected loads or supply circuits.
4. The cord and plug are intended for indoor use only.
5
PRODUCT DIAGRAM
1. Air Outlet Grill
2. Control Panel
3. Casters
4. Air Intake Grill
5. Remote Control Sensor
6. Air Filter
7. Carry Handle
8. Air Exhaust Hose Discharge Opening
9. Condensation Drain Hole
10. Power Cord
11. Product Manual (Not Shown)
12. Exhaust Hose
13. Exhaust Hose Connector
14. Window Kit Adapter
15. Remote Control
16. Caster Locks
17. Screws
18. Window Kit
19. Window Kit Adapter Extension
20. Drainage Hose
21. Rubber Plug