Models
SG-WAC-10ESE-C
SG-WAC-12ESE-C
Electronic Window Air Conditioner
Operating Instructions
Thank you for choosing a Soleus Air powered by Gree Air Conditioner. This owner’s manual will
provide you with valuable information necessary for the proper care and ma
intenance of your new
product. Please take a few moments to thoroughly read the instructions and familiarize yourself with
all the operational aspects of your new air conditioner.
For your own records, please attach a copy of your sales receipt to this manual. Also, write the store
name/location, date purchased, and serial number below:
Store Name: ____________________________________________________
Location: ______________________________________________________
Date Purchased: _________________________________________________
Serial Number (located on back of unit): ______________________________
IMPORT
Before installing and using
manual in a safe place for future reference. Your safety and the safety of others is very important to
us. Please pay attention to all safety messages outlined in this owner’s manual.
WARNING:
the following basic precautions:
• Plug into a grounded 3 prong outlet.
• Do not remove the ground prong.
• Do not use a plug adapter.
ANT
SAFETY INSTRUCTIONS
your air conditioner, please read this owner’s manual carefully. Store this
To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow
This
is a safety alert symbol.
This symbol alerts
death.
All safety messages will directly follow the safety alert symbol and/or the words
“DANGER” or “WARNING”.
you
to potential hazard
• Do not use an extension cord.
• Unplug the air conditioner before servicing
• Use two or more people to move and install the air
conditioner
s that can harm you or others or even cause
All Safety message
and what can happen if instructions are not followed correctly.
s alert you of potential hazards, how to reduce the chance of injury,
Failure to immediately follow these
ructions may cause serious injury
inst
or even death.
2
ELECTRICAL
REQUIREMENTS
The electrical ratings for your air conditioner are listed on the model and serial
number label located on the front left side of the unit (when facing the front).
Specific electrical requirements are listed in the chart below. Follow the
requirements below for the type of plug on the power supply cord.
Electrical Shock Hazard
Plug into a groun
Do not remove the ground prong.
Do not use an adapter
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock
Recommend
ded 3 prong outlet.
ed Ground Method
Wiring Require
115 volt (103.5 min.—126.5
•
max
)
•
0-12 amps
•
15-amp time-dela
circuit breaker
Use on single outlet circuit only
•
ments
y fuse or
er Supply Cord
Pow
For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a 3 prong power
supply cord with a grounded plug. To minimize the possibility of electrical shock, the cord must be plugged into a 3 prong
outlet and grounded in accordance with all local codes and ordinances. If a 3 prong outlet is not available, it is the customer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrician.
the customer’s responsibility:
It is
• To contact a qualified electrician
• To assure that the electrical installation is adequate
and in conformance with the National Electrical Code,
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
ANSI/NFPA 70 - latest edition, and all local codes and
ordinances.
LCDI Power Cord and Plug
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord that is required
by UL. This power supply cord contains state-of-the-art electronics that sense leakage current. If the cord is damaged
and leakage occurs, power will be disconnected from the unit.
The test and reset buttons
1. Plug power
cord into a grounded 3 prong outlet
on the LCDI Plug are used to check if the plug is functioning properly. To test the plug:
2. Press RESET (on some units a green light will turn on).
3. Press the TEST Button, the circuit should trip and cut all power to the air conditioner (on some units a green light
may turn off.
4. Press the RESET button for use. You will hear a click and the A/C is not ready for use.
NOTES:
• The RESET button must be engaged for proper use.
• The power supply cord must be replaced if it fails to trip when the TEST button is pressed and the unit fails to reset.
• Do not use the power supply cord as an ON/OFF switch. The
power supply cord is designed as a protection device.
• A damaged power supply cord must be replaced with a new
power supply cord from Soleus Air Powered by Gree.
• The power supply cord contains new user serviceable parts.
Opening the tamper-resistant case voids all warranty and performance claims.
NOTE: Your units power cord and plug may differ from the one
shown.
3
PAC
KING LIST
Packing List:
• Wi
• Remote Control
• AAA Batteries (2)
• Top Mounting Rail
• Top Mounting Rail Seal Strip
• Lock Frame (2)
• Accordion Panels (Left & Right)
ndow Air Conditioner
• Sash Lock (1)
• Window Sash Seal
• 3/4” Screw for Window Locking Bracket & Accordion
Panels, and sash lock (6)
• Foam Top Window Gasket
• Owner’s Manual
4
SPECIF
ICATIONS
• Noise level is measured at a distance of 3.28
• Power consumption is measured when the fan runs at the highest speed setting.
• These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
r Suppl
Powe
Rated Cooling Capacity (B
Cooling Power Input (Watts) 940
Rated Current Cooling (Am
EER/C.O.P 10.8
Noise Level dB(A) (H/M/L) 59
Air Flow H/M/L (CFM) 300/280/260
Dehumidifying Capacity 60 Pints pe
Product Dimensions (W” x D
Package Dimension
Net/Gross Weight (Lbs) 61/
Refrigerant Type R-410A
Model SG-WAC-10ESE-C
y (Ph/V/Hz) 1/115/60
TU/h) 10,000
perage) 8.6
” x H”) 19 x 21.25 x 14.625
s (W” x D” x H”) 22 x 23 x 17.125
ft away from the front of the unit in cooling mode.
SG-WAC-12ESE-C
/57/55
r day
19 x 21.25 x 14.625
68
1/115/60
12,000
1130
59/57/55
290/270/250
81 Pints per day
22 x 23 x 17.125
69/76
R-410A
10.3
10.8