Models
SG-WAC-10ESE
SG-WAC-12ESE
Electronic Window Air Conditioner
Operating Instructions
Thank you for choosing a Soleus Air powered by Gree Air Conditioner. This owner’s manual will
provide you with valuable information necessary for the proper care and maintenance of your new
product. Please take a few moments to thoroughly read the instructions and familiarize yourself with
all the operational aspects of your new air conditioner.
For your own records, please attach a copy of your sales receipt to this manual. Also, write the store
name/location, date purchased, and serial number below:
Store Name: ____________________________________________________
Location: ______________________________________________________
Date Purchased: _________________________________________________
Serial Number (located on back of unit): ______________________________
IMPORTANT SAFETY INSTRUCTIONS
Before installing and using your air conditioner, please read this owner’s manual carefully. Store this
manual in a safe place for future reference. Your safety and the safety of others is very important to
us. Please pay attention to all safety messages outlined in this owner’s manual.
WARNING: To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow
the following basic precautions:
• Plug into a grounded 3 prong outlet.
• Do not remove the ground prong.
• Do not use a plug adapter.
• Do not use an extension cord.
• Unplug the air conditioner before servicing
• Use two or more people to move and install the air
conditioner
This is a safety alert symbol.
This symbol alerts you to potential hazards that can harm you or others or even cause
death.
All safety messages will directly follow the safety alert symbol and/or the words
“DANGER” or “WARNING”.
All Safety messages alert you of potential hazards, how to reduce the chance of injury,
and what can happen if instructions are not followed correctly.
Failure to immediately follow these
instructions may cause serious injury
or even death.
2
ELECTRICAL REQUIREMENTS
The electrical ratings for your air conditioner are listed on the model and serial
number label located on the front left side of the unit (when facing the front).
Specific electrical requirements are listed in the chart below. Follow the
requirements below for the type of plug on the power supply cord.
Power Supply Cord
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove the ground prong.
Do not use an adapter
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock
Wiring Requirements
• 115 volt (103.5 min.—126.5
max)
• 0-12 amps
• 15-amp time-delay fuse or
circuit breaker
• Use on single outlet circuit only
Recommended Ground Method
For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a 3 prong power
supply cord with a grounded plug. To minimize the possibility of electrical shock, the cord must be plugged into a 3 prong
outlet and grounded in accordance with all local codes and ordinances. If a 3 prong outlet is not available, it is the customer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrician.
It is the customer’s responsibility:
• To contact a qualified electrician
• To assure that the electrical installation is adequate
and in conformance with the National Electrical Code,
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
ANSI/NFPA 70 - latest edition, and all local codes and
ordinances.
LCDI Power Cord and Plug
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as
required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination
on the load side and a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current
leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain deenergized until the devise has been manually reset. This is intended to reduce the risk of a fire in the power cord or
combustible materials nearby. The cord shields are not grounded and they must be considered a shock hazards if
exposed. The cord shield must not be connected to ground or to any exposed metal.
The test and reset buttons on the LCDI Plug are used to check if
the plug is functioning properly. To test the plug:
1. Plug power cord into a wall outlet
2. Press the TEST Button, the circuit should trip and cut all
power to the air conditioner
3. Press the RESET button for use
If a test is performed and the indicator light remains ON, the
current leakage has been detected. Do not use the air
conditioner or attempt to reset the LCDI Plug. Contact Customer
Service for troubleshooting recommendations.
3
PACKING LIST
6
Packing List:
• Window Air Conditioner
• AAA Batteries (2)
• Top Mounting Rail (Pre-installed at factory)
• Top Mounting Rail Seal Strip (Pre-installed at factory)
• 3/8” Screw for Top Mounting Rail (4) (Pre-installed at fac-
tory)
• Accordion Panels (2)
• Lock frame (2)
• 3/4” Screw for Top Mounting Rail, Lock frame
,Accordion Panels & Sash Lock (6)
• Sash Lock
• Foam Seal Strip/Gasket (2)
• Owner’s Manual
4