Thank you for choosing a Soleus Air powered by Gree Air Conditioner. This owner’s manual will
provide you with valuable information necessary for the proper care and m
aintenance of your new
product. Please take a few moments to thoroughly read the instructions and familiarize yourself with
all the operational aspects of your new air conditioner.
For your own records, please attach a copy of your sales receipt to this manual. Also, write the store
name/location, date purchased, and serial number below:
Store Name: ____________________________________________________
Location: ______________________________________________________
Date Purchased: _________________________________________________
Serial Number (located on back of unit): ______________________________
IMPORT
Before installing and u
manual in a safe place for future reference. Your safety and the safety of others is very important to
us. Please pay attention to all safety messages outlined in this owner’s manual.
WARNI
the following basic precautions:
• Plug into a grounded 3 prong outlet.
• Do not remove the ground prong.
• Do not use a plug adapter.
ANT SAFETY
NG: To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow
This
This symbol alerts
death.
All safety messages will directly follow the safety alert symbol and/or the words
“DANGER” or “WARNING”.
INSTRUCTIONS
sing your air conditioner, please read this owner’s manual carefully. Store this
• Do not use an extension cord.
• Unplug the air conditioner before servicing
• Use two or more people to move and install the air
conditioner
is a safety alert symbol.
you
to potential hazards that can harm you or others or even cause
All Safety me
and what can happen if instructions are not followed correctly.
ssages alert you of potential hazards, how to reduce the chance of injury,
Failure to immediately follow thes
instructions may cause serious injury
or even death.
2
e
ELECTRICAL
REQUIREMENTS
The electrical ratings for your air conditioner are listed on the model and serial
number label located on the front left side of the unit (when facing the front).
Specific electrical requirements are listed in the chart below. Follow the
requirements below for the type of plug on the power supply cord.
Electrical Shock Hazard
Plug into a groun
Do not remove the ground prong.
Do not use an adapter
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock
Recommend
ded 3 prong outlet.
ed Ground Method
Wiring Re
115 volt (103.5 min.—126.5
•
max
•
0-12 amps
•
15-amp time-dela
circuit breaker
Use on single outlet circuit only
•
quire
)
ments
y fuse or
er Supply Cord
Pow
For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a 3 prong power
supply cord with a grounded plug. To minimize the possibility of electrical shock, the cord must be plugged into a 3 prong
outlet and grounded in accordance with all local codes and ordinances. If a 3 prong outlet is not available, it is the customer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrician.
It is the customer’s responsibility
:
• To contact a qualified electrician
• To assure that the electrical installation is adequate
and in conformance with the National Electrical Code,
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
ANSI/NFPA 70 - latest edition, and all local codes and
ordinances.
LCDI Power Cord and Plug
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as
required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination
on the load side and a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current
leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain deenergized until the devise has been manually reset. This is intended to reduce the risk of a fire in the power cord or
combustible materials nearby. The cord shields are not grounded and they must be considered a shock hazards if
exposed. The cord shield must not be connected to ground or to any exposed metal.
The test and reset buttons on the LCDI Plug are used to check if
the plug is functioning properly. To test the plug:
1. Plug power
cord into a wall outlet
2. Press the TEST Button, the circuit should trip and cut all
power to the air conditioner
3. Press the RESET button for use
If a test is performed and the indicator light remains ON, the
current leakage has been detected. Do not use the air
conditioner or attempt to reset the LCDI Plug. Contact Customer
Service for troubleshooting recommendations.
NOTE: Your units power cord and plug may differ from the one shown.
3
PACK
•
•
•
•
•
•
•
•
•
•
SP
ING LIST
Window Air Conditioner
Top Mounting Rail
Top Mounting Rail Seal Strip
3/8” Screw for Top Mounting Rail (4)
Accordion Panels (2)
Sash Lock
Window Sash Seal
3/4” Screw for Sash Lock and Accord
Foam Top Window
Owner’s
EC
Manual
IFICATIONS
Gasket
ion Panels (6)
• Noise level is measured at a
• Power consumption is measured when the fan runs at the highest speed setting.
• These specifications are for reference only. For actual data, please refer to the rating label on the unit.
Model
Power Supply (Ph/V/Hz) 1/115/60
Dehumidifying Capacity (Pints
Rated Cooling Cap
Rated Heating Cap
Cooling Power Input (Watts) 515
Heating Power Input (Watts) /
Rated Curren
Rated Curren
EER/C.O.P 9.7 EER
Noise Level d
Air Flow
120 CFM
Design Pressure (PSIG) (H/L) /
Dimensio
Package Dimensi
Net/Gross
Refrigerant Charge
distance of 3.28 ft away from the front of the unit in cooling mode.
M
/Day) 26
acity (BTU/h) 5,000
acity (BTU/h) /
t Cooling (Amperage) 4.9
t Heating (Amperage) /
B(A)
ns (W” x D” x H”)
ons (W” x D” x H”) 17.875 x 15.25 x 14.75
Weight (Lbs) 40/44
(Oz) 9.17
SG-WAC-05SM-C
Hz
56/54
155 155
CFM
16.125 x 13.125 x 1
2
DISCLAIMER
ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’S MANUAL
PRESENTATION OF THE MANUFACTURER. SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT
TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN.
4
ARE THE