Soleus Air MAC-8000 User Manual

Sales Inquiries: 800-934-9194
8,000 BTU Portable Air Conditioner, Dehumidifier and Fan
OWNER’S MANUAL Model # MAC-8000
TABLE OF CONTENTS
INTRODUCTION.............................................................................................................................................................3
IMPORTANT SAFEGUARDS.....................................................................................................................................3
LCDI POWER CORD AND PLUG.................................................................................................................................4
PRODUCT DIAGRAM....................................................................................................................................................5
FRONT........................................................................................................................................................................5
BACK..........................................................................................................................................................................5
ACCESSORIES...........................................................................................................................................................5
INSTALLATION...............................................................................................................................................................6
SELECTING THE LOCATION...................................................................................................................................6
MOUNTING THE EXHAUST HOSE..........................................................................................................................6
WALL MOUNTING.....................................................................................................................................................6
WINDOW KIT INSTALLATION..................................................................................................................................7
CONTROL PANEL...........................................................................................................................................................8
OPERATION.....................................................................................................................................................................9
COOLING ...................................................................................................................................................................9
DEHUMIDIFYING.....................................................................................................................................................9
FAN .............................................................................................................................................................................9
EMPTYING THE W ATER BUCKET...........................................................................................................................9
CONTINUOUS DRAINAGE.........................................................................................................................................10
REMOTE CONTROL....................................................................................................................................................10
MAINTENANCE............................................................................................................................................................ 11
CLEANING THE HOUSING .................................................................................................................................... 11
CLEANING THE FILTER......................................................................................................................................... 11
END OF SEASON STORAGE....................................................................................................................................... 11
TROUBLESHOOTING..................................................................................................................................................12
TECHNICAL SPECIFICATIONS................................................................................................................................13
WARRANTY ...................................................................................................................................................................14
2
INTRODUCTION
Thank you for purchasing the Soleus Air MAC-8000 8,000 BTU Portable Air Conditi oner and Dehumidifier. This unit is designed to improve indoor living and working comfort by providing cooling, dehumidifying, and ventilation with minimal installation.
This multi-functional unit operates as an air conditioner, dehumidifier and fan. When operating as an air conditioner, this unit is designed for spot cooling or cooling a room no larger than 150 square feet with a standard eight foot ceiling height. When using this appliance, always exercise basic safety precautions.
Please complete the following information for future reference. Retain this owner’s manual with your sales receipt as a permanent record of your purchase.
Serial Number: _________________________________________________________ Date of Purchase: _______________________________________________________ Place of Purchase: ______________________________________________________
IMPORTANT SAFEGUARDS
Before installing and using your portable air conditioner and heater, it is important that you read this owner’s manual carefully. Store this manual in a safe place for future reference.
This instruction manual is used for guidance and does not fo rm part of a contract. It res erves the right to ma ke technical changes without prior notice.
1. Always place the unit on a level surface.
2. The appliance shall be installed in accordance with national wiring regulation.
3. The unit must be connected to a correctly grounded power supply. For your safety, this unit is grounded through the power cord plug when connected to a grounded wall outlet. Do not use an adapter plug or extension cord.
4. Do not install the unit in an area where gas leakage may occur and/or in an explosive atmosphere.
5. Do not apply an insecticide or any type of flammable spray on the unit.
6. Confirm drainage piping is connected properly.
7. Do not start or stop the unit by inserting or pulling out the power plug.
8. Do not operate with wet hands.
9. Close supervision is necessary when the unit is used near children. The unit in not intended for use by children.
10. Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills.
11. Do not expose skin or eyes directly to cool air for a long period of time.
12. If an abnormal odor or smoke comes out of the unit, disconnect the unit immediately and contact a qualified service technician. (see page 14)
13. When opening the filter cover, do not touch the metal parts in the unit’s interior.
14. Do not immerse the unit in water or any type of liquid. Do not use the unit in the immediate surroundings of a bath, shower, or swimming pool, or in any other steamy, wet areas.
15. When cleaning the unit, always turn the unit off and unplug the power cord.
16. Always inspect the power cord for signs o f damage before use. If the power cord is damaged, it must be replaced by the manufacturer or a qualified service technician.
17. Do not place a plant or allow a pet in the direct path of the airflow to avoid injury.
18. Do not put a stove, etc, where it would be exposed to the direct airflow. It may affect combustion.
19. Do not sit on the unit or place anything on it.
20. Do not dispose of the remote control in fire, the batteries inside may explode or leak.
21. Before storing, the water must be drained from the unit and the filters cleaned.
3
LCDI POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit tr ip) if the nominal current le akage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain de-energized until the devise has been manually reset. This is intended to reduce the risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any exposed metal.
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:
1. Plug power cord into wall outlet
2. Press TEST Button, circuit should trip, cutting power to the air conditioner
3. Press RESET button for use
If a test is performed and the indicator light remains ON, current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Customer Service for troubleshooting recommendations.
WARNING:
1. DO NOT press TEST button while the air conditioner is operating.
2. The TEST and RESET buttons should not be used as “ON” and “OFF” switches.
3. The cord and plug are not intended to offer protection to externally connected loads or supply circuits.
4. The cord and plug are intended for indoor use only.
4
PRODUCT DIAGRAM
B
BE C
C
B
FRONT
A. Control panel B. Interior Louvers C. Exterior Louvers D. Casters E. Recessed Handle
A
F. Water Bucket G. Power Cable and Plug
BACK
A. Hot air outlet grill
B. Air inlet grill C. Filter D. Drain Valve
ACCESSORIES
Flexible exhaust hose and window exhaust adapter
F
D
G
A
D
3-Piece adjustable window kit
Drain tube
4 3/8” screws
5
Loading...
+ 9 hidden pages