Please read this owner’s manual
carefully before operating the unit.
66126113.p6502-12-21, 15:4417
POWERED BY
INTRODUCTION
Thank you for purchasing theMac 7500 portable air-conditioner. This unit is
designed for improving living and working comfort by providing cooling, dehumidifying and
fan functions only with a minimum installation required. With its whisper quite operation and
attractive design, you will enjoy the convenience and comfort that this unit provides for many
years to come.
When operating as an air conditioner, this unit is designed for spot cooling or cooling for a room
1
no larger than 150 square feet with the standard ceiling height 7-
/2 ft.
ALERT SYMBOLS
The following symbols used in this manual, alert you to potentially dangerous conditions to
users, service personnel or the appliance:
this symbol refers to a hazard or unsafe practice, which can
result in severe personal injury or death.
this symbol refers to a hazard or unsafe practice, which can
result in personal injury or product or property damage.
IMPORTANT SAFEGUARDS
Read these instructions carefully before using this air
•
conditioner. If you still have any ditticulties or problems, consult your dealer for help.
Never use or store gasoline or other flammable vapor or
•
liquid near the air conditioner.
66126113.p6502-12-21, 15:441
This air conditioner has no ventilator for taking in fresh air
•
from out of doors. You must open doors or windows frequently when you use gas or oil heating appliances in the
same room ,which consume a lot of oxygen from the air.
Otherwise, there is a risk of suffocation in extreme cases.
1
Unplug unit from the electrical outlet when not in use and
•
before cleaning it.
Do not use an adapter plug extension cord.
•
Do not use near gas appliances, open flames (fireplaces) or
•
near the vicinity flammable liquids.
Do not operate this unit if it had a damaged cord or plug or if
•
it is not warking properly, or has been dropped or damaged
in any manner. Take the unit to the nearest authorized. Service Facility for examination, repair or electrical/mechanical
adjustment.
The use of accessories and attachments not recommended
•
or sold bymay cause fire, electric shock or
injury.
To protect against risk of electrical shock, do not immerse
•
the unit, cord or plug in water or any other liquid.
Do not cut or remove the third (ground) prong from the power
•
cord.
If the plug gets hot, call a qualified electrician.
•
Close supervision is required when the unit is used by or near
•
children.
Do not stick anything into the air outlet of the air conditioner.
•
Do not use in a room with poor air circulation.
•
66126113.p6502-12-21, 15:442
Do not expose the unit to direct sunlight.
•
Do not use the unit near water.
•
2
PACKAGE CONTAINS:
Mobile Air Conditioner
LITHIUM BATTERY 3V
–
Air Exhaust Duct
Exhaust Duct Window Kit Adapter
Romote Controller
for this application.Otherwise
the drain will leak.
66126113.p6502-12-21, 15:443
3
Exhaust Duct
Window Kits
Exhaust Duct
Unit Terminal End
Window Kit Adaptor
Exhaust Duct
When you use the unit as an air conditioner, the hot exhaust air must be directed out of the
room. The exhaust duct is used to allow the hot air out. DO NOT INSTALL OR USE THE
EXHAUST DUCT WHEN THE UNIT IS OPERA TED AS A DEHUMIDIFIER OR FAN.
a)
Slide exhaust connector all the
over the hot Air outlet grill.
b)
Mount the external and of the ex-
1
haust duct onto a bole of 5
mm) on the wall for optional wall
hot air outlet installation.
/4" (132
4
66126113.p6502-12-21, 15:444
Or connect the window kit adaptor to the external end of the exhaust duct for a window
c)
or sliding door hot air outlet installation.
NOTE: In order to increase the efficiency, the exhaust duct should be keep as short and
straight as possible. The exhaust hose can be cut shorter by unthreading either end of the
exhaust duct counter clockwise. It is not recommended to increase the manufacturer’s length
of the exhaust hose. This may impede or damage the unit.
Window Kit Installation
Open window or sliding door for approximately 5 inches (130 mm).
a)
Adjust the length of the window kit to the same length of the window or the sliding door.
b)
Use all three panels if necessary.
Use screws to affix the window kit length.
c)
Place the window kit to the window or sliding door. Close the window or door as far as
d)
it goes.
Mount the window kit extension of the exhaust host onto the window kit.
e)
Use screws on the window kit extension if necessary.
f)
NOTE: When using the window kit on a window or sliding door it will cause the window or
sliding door not to be properly closed and locked. Additional security measurements should be
taken.
5
windows
exhaust air opening
66126113.p6502-12-21, 15:445
CONTROL PANEL
REMOTE CONTROLLER
66126113.p6502-12-21, 15:446
6
OPERA TION USING CONTROL PANEL
1)
For Manual Mode:
Press the Mode Button
a)Cool - Cooling function on indicator.
b)Dry - Dehumidify function on indicator.
c)Fan - Fan on indicator.
2)
For Cooling Operation:
a)Be sure that the drain tank is properly placed in the unit.
b)Install the exhaust duct properly.
c)Plug the Power Cord to the power outlet.
d)Press the Mode Button until the cool indicator is on.
NOTE: During hot days, the unit will cool off the room most efficiently by setting the fan at the
lowest speed. Reducing the length of the exhaust duct, insulating the exhaust duct and keeping
direct sunlight to a minimurn will also improve the cooling efficiency.
3)
Dehumidifying Operation:
a)Be sure that the drain tank is properly placed in the unit.
b)Plug the Power Cord to the power outlet
c)Turn on the unit by pressing the ON/OFF Button on the control panel.
d)Press the Mode Button until the DRY indicator is on.
NOTE: Do not use the exhaust duct when the unit is running at dehumidisying mode. Y ou must
remove the exhaust duct from the unit. When the unit is running at dehumidifying mode, the fan
speed cannot be adjusted.
Keep the windows and the doors closed to aid the effectiyeness of the unit in removing the
moisture from the room.
66126113.p6502-12-21, 15:447
7
4)
Fan Operation:
a)Plug the Power Cord to the power outlet.
b)Turn on the unit by pressing the ON/OFF Button on the control panel.
c)Press the Mode Button until ‘FAN’ indicator is on.
d)Select the fan speed by pressing the Fan Speed Button.
NOTE: When the unit is running on fan mode, the exhaust duct is inoperative and is not
required.
OPERATION USING REMOTE CONTROLLER
The remote controller provided with the unit may operate this portable air conditioner. The
remote controller uses one LITHIUM BATTERY 3V
mote controller.
–
. Install the battery before using the re-
1. Press the On/Off key to turn on the unit.
2. Press Mode Key to:
a)Cool indicator is on = Cooling Function
b)Dry indicator is on = Dehumidify Function
c)Fan indicator is on = Fan Function
3.
Fan Speed:
a)Press the Fan Speed key to turn fan speed to high or low.
4.
Swing:
a)Press swing key to turn on auto swing function.
Do not dispose of batteries in fire, batteries may
explode or leak.
66126113.p6502-12-21, 15:448
8
CONDENSA TE WATER DRAINAGE
1)
Internal Water Tank
When operating in cooling or dehumidifying mode, the condensate water will drain into
the internal water tank.
Depending on the surrounding humidity
, the unit can continuously operate for 2 to 12 hours before the internal water tank is full. When the internal
water tank gets full, a beep slarm will sound eight times for 15 seconds. The compressor stops running and the fan will continue to run in the set speed for three minutes
before the entire unit automatically shuts off.
When the water tank is full, take out the entire water tank slowly and discard the water
inside the tank, place it back to its original position. Y ou will then be able to turn on the
unit again.
If you want to take out the internal tank before it is full of water, please stop the unit
first. Wait for 3 minutes before taking out the water tank to prevent the condensate
water from discharging into the unit.
NOTE: Do not take out the water tank when the unit is running on either cooling or dehumidifying mode or the alarm will sound and the compressor stops. The mode will automatically
change to FAN mode and the compressor will require approximately 3 minutes to restart to the
cooling/dehumidifying cycle.
66126113.p6502-12-21, 15:449
9
Do not remove the water tank when the unit is in use.
Always turn “Off” the unit before removing water tank.
Periodically inspect and clean the drain valve to prevent
clogging.
METHOD OF CONTINUOUS DRAINAGE:
1. Slide out drain valve from the left side of the unit.
2. Connect a rubber pipe to the valve (not included).
3. Make sure the rubber pipe drains downward.
66126113.p6502-12-21, 15:4410
10
AIR FIL TER
Soleus Air recommends cleaning your air filter at least after every two weeks of use. Keep-
•
ing your air filter clean will maximize the performance and life of this product.
Open the air filter cover on the left side of the unit (fig. a)
•
Remove the filter from the cover.
•
Wash the filter using warm water and a mild dishwasher detergent.
•
Allow to air dry before replacing in unit.
•
Fig. a
Water Tank
•
Using the handle, slowly remove water tonk from unit (fig. b).
•
Pour out any condensation accumulated in water tank (fig. c)
•
Wash water tank using warm water and a mild dishwasher detergenr.
•
Allow to dry completely.
•
Replace water tank in unit (fig. d).
Fig. b
Fig. c
Fig. d
66126113.p6502-12-21, 15:4411
11
NOTE: Be very careful when using an external water tank. The unit will not shut off automatically when an external water tank is full. Spill water can cause substantial damages to carpet,
furniture and other valuables.
Do not use lengthy drainage tabing without a condensate water pump.
MAINTENANCE
NOTE: Make sure power is off and the plug is pulled out of the power outlet before performing
any maintenance activities.
1)
2)
Case
a)Keep the unit from being exposed directly to the sun for possible color fading.
b)Clean the surface with a damp cloth and dry it with a soft towel.
Storing the Unit for an Extended Period of Time
a)Ensure that the water drain tank is empty.
Remove the stopper from the water drain pipe and allow draining until empty.
(Fig. e)
b)The water drain valve should be reinserted back in the unit.
c)The filter should be cleaned and air dried.
d)The power cable must be disconnected from power outlet and neatly rolled.
(Fig. f)
e)The unit should be stored in a dry place.
Fig. e
Fig. f
66126113.p6502-12-21, 15:4412
12
TROUBLE SHOOTING
PROBLEMPOSSIBLE CAUSEREMEDY
Unit does not operate
Unit does not cool
room
Unit is umpluggedSecorely plug receptacle into the power
outlet
Drain tank is fullEmpty water tank
Water tank not installed correctlyCompletely insert water tank
Air exhaust is cloggedClear exhaust hose
There is a heating source in the roomTurn down or off the other heating
source
Air filter is dirtyClean or replace the air filter
Air exhaust is not installed correctlyCheck the air exhaust duct to make sure
that the hot exhaust air is let out of the
room freely
Room is too big or too much amblent
sunlight is reaching in
This unit provides spot cooling or cool-
ing for a room no larger than 150
square feel with standard ceilling height
1
7
/2"
There is frost on the evaporatorThe unit will defrost automatically and
return to operation afterwards
In dehumidifying mode,
no cool air coming out
There is frost on the evaporatorThe unit will defrost automatically and
will return to operation afterwards
Noise or vibrationSurface is not levelPlace unit on a level surface and away
from obstructions
Surface is not level
Drainage pipe is loose
Unit has been moved
Place unit on a level surface away from
obstructions
When moving unit, empty drain tank first
and keep unit upright at all times
Stopper on water drain pipe is loose
Make sure the stopper on the water
drain pipe is securely in place
Machino stops and
Air exhaust is not attached proparty
Check installation of air exhaust hose
starts
Air exhaust is curved too much
Try to keep the air exhaust horizontal
66126113.p6502-12-21, 15:4413
13
SPECIFICA TIONS
Model #MAC - 7500
Power Source115V ~ / 60Hz
Cooling capacity7500 BTU/h
Dehumidifyling capacity24.0 liters/day
Cooling input power1000W
Rated current8.7A
Refrigerant typeHCFC R22
Refrigerant capacity1.15 lb
Operating Range - CoolingMax 95°F Dry Bulb - 71°F Wet Bulb
(indoor air temperature)Min 67°F Dry Bulb - 57°F Wet Bulb
Unit dimensions (H x D x W)31" x 12.8" x 16.3"
Specifications are subject to change without notice
PRODUCT INFORMATION
If you have problems or questions concerning your air conditioner, you will need the following
information. Model and Serial numbers are on the nameplate on the back of the unit.
Model No.
Date of Purchase
Dealer’s Name
Purchaser’s Name
Day Phone Evening Phone
Serial No.
Dealers Address
66126113.p6502-12-21, 15:4414
14
DISCLAIMER
ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS
USER’S MANUAL ARE THE PRESENTATION OF THE MANUFACTURER SOLEUS
INTERNA TIONAL HAS NOT CONDUCTED INDEPENDENT TESTS FOR THE INFORMATION AND THE SPECIFICA TIONS PRESENTED HEREWITHIN.
CONT ACT INFORMATION
ForOptional and Spare Parts
Technical Support
Warranty Claim
Customer Service
Please Call (888) 8-Soleus
Or Write to:
Soleus International Inc.
9451 Telstar Ave.
El Monte CA 91731 USA
www.soleusair.com
66126113.p6502-12-21, 15:4415