Soleus Air LX-140 User Manual

14,000 BTU Portable Air Conditioner
12,000 BTU Heat Pump
Operating Instructions
®
Model No. LX-140
© 2006 Soleus Air International
Thank you for choosing a Soleus Air LX-140 Portable Air Conditioner & Heat Pump. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Soleus Air Portable Air Conditioner with Heat Pump technology.
For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date purchased, and serial number below:
Store Name: ____________________________________________________
Location: ______________________________________________________
Date Purchased: _________________________________________________
Serial Number (located on back of unit): ______________________________
IMPORTANT INSTRUCTIONS
Before installing and using your portable air conditioner, please read this owner’s manual carefully. Store this manual in a safe place for future reference.
1) Always place the unit on a level surface.
2) Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this
manual.
3) Maintain at least 10 inches (25 cm) clearance space around this unit. Do not block or cover air inlet or
outlet grilles.
4) The unit must be connected to a correctly grounded power supply.
5) Do not start or stop the unit by inserting or pulling out the power plug.
6) Do not use an adapter plug or extension cord.
7) Do not use the unit in the immediate surroundings of a bath, a shower or a swimming pool.
8) Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills unless instructed by this
manual.
9) Do not let children play near this unit.
10) Always inspect the cord for signs of damage before use. If the power cord is damaged, it must be replaced
by the manufacturer or a qualified service technician.
11) When cleaning the unit, always turn the unit off and unplug the power cord.
PACKAGE CONTENTS
Portable Air Conditioner Exhaust Hoses (2) Hose Adapters (2) Window Kit Adapter (2) Remote Control AAA Batteries (2) Window Kit - 4 Sliding Panels (1 dual hose panel, 1 single hose panel, 2 extension panels) Air Intake and Outlet Covers (2) Owner’s Manual
WARNING: This unit has a voltage rating of 115 volts. The cord has a plug as shown in A. An adapter as shown in C is available for connecting three-blade grounding-type plugs to two-slot receptacles. The grounding lug extending from the adapter must be con­nected to a permanent ground such as a properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is available.
DO NOT DEFEAT THE SAFETY PURPOSE OF THE GROUNDED PLUG.
SPECIFICATIONS
The cooling capacity is meas­ured at an ambient temperature of DB 86 °F, WB 78 °F.
Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in cooling mode.
Power consumption is meas­ured when the fan runs at the highest speed setting.
These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
If the environment temperature is higher than the max operat­ing temperature or lower than the minimum operating tem­perature, the air conditioner may not work properly.
MODEL LX-140
COOLING CAPACITY 14,000 BTU/H
HEATING CAPACITY 12,000 BTU/H
DEHUMIDIFYING CAPACITY 60 pts/Day
POWER
AIR FLOW VOLUME 225 CFM
POWER SOURCE
SOUND PRESSURE LEVEL 46 dB(A)
NET WEIGHT 82 Lbs
OPERATING
TEMPERATURE
DIMENSIONS
REFRIGERANT R22
COOLING 1350W
HEATING 1350W
12/12 AMP HEATING/COOLING
COOLING
HEATING
ASSEMBLED
PACKAGE
17.7” W ×32.9” H ×18.9” D
19.9” W ×34.5” H ×22.5” D
115 V~ 60 HZ
60.8-108
23-89.6
PRODUCT DIAGRAM
Louvers
Signal Receptor
Control Panel
Filter Compartment
Casters
Air Intake Cover/Filter
PARTS & ASSEMBLY
PARTS
EXHAUST HOSE
WINDOW KIT
ASSEMBLY & INSTALLATION
INSTALLATION
When the unit is operating as an air conditioner, heater, or dehumidifier, the unit draws in fresh outdoor air and exhausts hot air (in AC or dehumidifier mode) or cool air (in Heat mode) out of the room to complete the air exchange. When the unit is operating in fan mode, no outdoor air exchange takes place. The window kit and exhaust hose do not need to be installed when the unit is used as a fan.
NOTE: The supplied window kit can be installed in sliding windows and sliding glass doors up to 8 ft. long (approximate length).
MOUNTING THE EXHAUST HOSES
Choose a suitable location, near a grounded electrical outlet and suitable window or door. Remove
packaging and locate components.
Extend both ends of the exhaust hoses approximately 6 inches.
Screw the window kit adapter onto one end of the exhaust hose clockwise. Screw the hose adapter onto
the other end of the exhaust hose clockwise. Repeat on the other exhaust hose.
Remove outlet covers from the back of the unit by screwing them counter-clockwise, then lifting up.
Mount the exhaust hoses onto the back of the unit by locking the hose adapters into place.