14,000 BTU Portable Air Conditioner
12,000 BTU Heat Pump
Operating Instructions
®
Model No. LX-140
© 2006 Soleus Air International
Thank you for choosing a Soleus Air LX-140 Portable Air Conditioner & Heat Pump. This owner’s
manual will provide you with valuable information necessary for the proper care and maintenance of
your new product. Please take a few moments to thoroughly read the instructions and familiarize
yourself with all the operational aspects of your new Soleus Air Portable Air Conditioner with Heat
Pump technology.
For your own records, please attach a copy of your sales receipt to this manual. Also, write the store
name/location, date purchased, and serial number below:
Store Name: ____________________________________________________
Location: ______________________________________________________
Date Purchased: _________________________________________________
Serial Number (located on back of unit): ______________________________
IMPORTANT INSTRUCTIONS
Before installing and using your portable air conditioner, please read this owner’s manual carefully. Store this
manual in a safe place for future reference.
1) Always place the unit on a level surface.
2) Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this
manual.
3) Maintain at least 10 inches (25 cm) clearance space around this unit. Do not block or cover air inlet or
outlet grilles.
4) The unit must be connected to a correctly grounded power supply.
5) Do not start or stop the unit by inserting or pulling out the power plug.
6) Do not use an adapter plug or extension cord.
7) Do not use the unit in the immediate surroundings of a bath, a shower or a swimming pool.
8) Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills unless instructed by this
manual.
9) Do not let children play near this unit.
10) Always inspect the cord for signs of damage before use. If the power cord is damaged, it must be replaced
by the manufacturer or a qualified service technician.
11) When cleaning the unit, always turn the unit off and unplug the power cord.
2
PACKAGE CONTENTS
Portable Air Conditioner
Exhaust Hoses (2)
Hose Adapters (2)
Window Kit Adapter (2)
Remote Control
AAA Batteries (2)
Window Kit - 4 Sliding Panels (1 dual hose panel, 1 single hose panel, 2 extension panels)
Air Intake and Outlet Covers (2)
Owner’s Manual
WARNING: This unit has a voltage rating of 115
volts. The cord has a plug as shown in A. An adapter as
shown in C is available for connecting three-blade
grounding-type plugs to two-slot receptacles. The
grounding lug extending from the adapter must be connected to a permanent ground such as a properly
grounded outlet box. The adapter should not be used if
a three-slot grounded receptacle is available.
DO NOT DEFEAT THE SAFETY PURPOSE OF
THE GROUNDED PLUG.
SPECIFICATIONS
• The cooling capacity is measured at an ambient temperature
of DB 86 °F, WB 78 °F.
• Noise level is measured at a
distance of 3.28 ft away from
the front of the unit, when the
unit is in cooling mode.
• Power consumption is measured when the fan runs at the
highest speed setting.
• These specifications are for
reference only. For actual data,
please refer to the rating label
on the back of the unit.
• If the environment temperature
is higher than the max operating temperature or lower than
the minimum operating temperature, the air conditioner
may not work properly.
MODEL LX-140
COOLING CAPACITY 14,000 BTU/H
HEATING CAPACITY 12,000 BTU/H
DEHUMIDIFYING CAPACITY 60 pts/Day
POWER
AIR FLOW VOLUME 225 CFM
POWER SOURCE
SOUND PRESSURE LEVEL 46 dB(A)
NET WEIGHT 82 Lbs
OPERATING
TEMPERATURE
DIMENSIONS
REFRIGERANT R22
COOLING 1350W
HEATING 1350W
12/12 AMP HEATING/COOLING
COOLING
HEATING
ASSEMBLED
PACKAGE
17.7” W ×32.9” H ×18.9” D
19.9” W ×34.5” H ×22.5” D
115 V~ 60 HZ
60.8℉-108℉
23℉-89.6℉
3
PARTS & ASSEMBLY
PARTS
EXHAUST HOSE
WINDOW KIT
ASSEMBLY & INSTALLATION
INSTALLATION
When the unit is operating as an air conditioner, heater, or dehumidifier, the unit draws in fresh outdoor air and exhausts
hot air (in AC or dehumidifier mode) or cool air (in Heat mode) out of the room to complete the air exchange. When the
unit is operating in fan mode, no outdoor air exchange takes place. The window kit and exhaust hose do not need to be
installed when the unit is used as a fan.
NOTE: The supplied window kit can be installed in sliding windows and sliding glass doors up to 8 ft. long
(approximate length).
MOUNTING THE EXHAUST HOSES
• Choose a suitable location, near a grounded electrical outlet and suitable window or door. Remove
packaging and locate components.
• Extend both ends of the exhaust hoses approximately 6 inches.
• Screw the window kit adapter onto one end of the exhaust hose clockwise. Screw the hose adapter onto
the other end of the exhaust hose clockwise. Repeat on the other exhaust hose.
• Remove outlet covers from the back of the unit by screwing them counter-clockwise, then lifting up.
• Mount the exhaust hoses onto the back of the unit by locking the hose adapters into place.
5