Soleus Air KY80BB User Manual

8,000/10,000/12,000 BTU
Portable Air Conditioner
Operating Instructions
Model No.: PS08-01 PS10-01
Model No.: PS12-03
Ref: KY120
KY100
3119233
V160310
Thank you for choosing a Soleus Air Portable Air Conditioner. This owner’s manual will provide
you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Soleus Air Portable Air Conditioner.
For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date purchased, and serial number below:
Store Name: ____________________________________________________
Location: _____________________________________________________
Date Purchased: _________________________________________________
Serial Number (located on back of unit): ______________________________
IMPORTANT INSTRUCTIONS
Before installing and using your portable air conditioner, please read this owner’s manual carefully. Store this
manual in a safe place for future reference.
1) Always place the unit on a level surface.
2) Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual.
3) Maintain at least 10 inches (25 cm) clearance space around this unit. Do not block or cover air inlet or outlet
grilles.
4) The unit must be connected to a correctly grounded power supply.
5) Do not start or stop the unit by inserting or pulling out the power plug.
6) Do not use an adapter plug or extension cord.
7) Do not use the unit in the immediate surroundings of a bath, a shower or a swimming pool.
8) Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills unless instructed by this
manual.
9) Do not let children play near this unit.
10) Always inspect the cord for signs of damage before use. If the power cord is damaged, it must be replaced by
the manufacturer or a qualified service technician.
11) When cleaning the unit, always turn the unit off and unplug the power cord.
12) Do not mix old and new batteries in the remote control.
Do not mix Alkaline, Standard (Carbon - Zinc) or Rechargeable (Nickel - Cadmium) Batteries.
2
PACKAGE CONTENTS
Portable Air Conditioner (1) Exhaust Hose (1) Exhaust Hose Connector (1) Window Kit Adapter (1) Window Kit Adapter Extension (1) Rubber Plug (1) Screws (2) Remote Control (1) AAA Batteries (2) Caster Lock (2) Window Kit - Sliding Panels (3) Drainage Hose (1)
SPECIFICATIONS
The cooling capacity is measured at an ambient temperature of DB 95˚F, WB 83 ˚F.
Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in cool-
ing mode.
Power consumption is measured when the fan runs at the highest speed setting.
These specifications are for reference only. For actual data, please refer to the rating label on the back
of the unit.
If the environment temperature is higher than the max operating temperature or lower than the minimum operat-
ing temperature, the air conditioner may not work properly.
MODEL NUMBER
COOLING CAPACITY 8,000 BTU/Hr 12,000 BTU/Hr 10,000 BTU/Hr
DEHUMIDIFYING CAPACITY 86 pts per Day 117 pts per Day 107 pts per Day
COOLING POWER USAGE 914 Watts, 8.3 Amps 1200 Watts, 10.2 Amps 991 Watts, 9.1 Amps
AIR FLOW VOLUME 206 CFM 206 CFM 206 CFM
POWER SOURCE 115 V / 60 HZ 115 V / 60 HZ 115 V / 60 HZ
SOUND PRESSURE LEVEL 53 dB(A) 54 dB(A) 53 dB(A)
PS08-01
(Ref: KY80)
PS10-01
(Ref: KY100)
PS12-03
(Ref: KY120)
PRODUCT WEIGHT 59.5 Lbs 62.8 Lbs 60.6 Lbs
OPERATING
TEMPERATURE
PRODUCT DIMENSIONS
REFRIGERANT R-410A R-410A R-410A
70℉-95 70℉-9570℉-95
10.625” W×18.875” D ×27.375” H
10.625” W×18.875” D
3
×27.375” H
10.625” W×18.875” D ×27.375” H
LCDI POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexi­ble cord with no termination on the load side and a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain de-energized until the devise has been manually reset. This is intended to reduce the risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any exposed metal.
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:
1. Plug power cord into wall outlet
2. Press TEST Button, circuit should trip, cutting power to the air conditioner
3. Press RESET button for use
If test button is pressed and unit can still be turned on, current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Soleus Home Comfort Customer Service for trou­bleshooting recommendations.
Note: Your unit’s power cord may differ from the one shown.
WARNING:
1. DO NOT press the TEST button while the air conditioner is operating.
2. The TEST and RESET buttons should not be used as ONand OFFswitches.
3. The cord and plug are not intended to offer protection to externally connected loads or supply circuits.
4. The cord and plug are intended for indoor use only.
RESET
TEST
4
ALTERNATIVE LCDI POWER CORD AND PLUG
WITH LED LIGHT
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexi­ble cord with no termination on the load side and a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value.
The cord will remain de-energized until the devise has been manually reset. This is intended to re
duce the
risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they
must be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any exposed metal.
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:
1. Plug power cor
d into wall outlet. The LED light will turn on.
2. Press TEST Button, circuit should trip, cutting power to the air conditioner. When this occurs, the LED light will turn off.
3. Press RESET button to restore power to the machine. Once power is restored, the LED light
will turn on again.
If test button is pressed and unit can still be turned on, current leakage has been detected. Do not use
air conditioner or attempt to reset the LCDI Plug. Contact Soleus Home Comfort for troublesh
ooting
recommendations.
LED LIGHT
Note: Your unit's power cord and plug may differ from the one shown.
the
WARNING:
1. DO NOT press the TEST button while the air conditioner is operating.
2. The TEST and RESET buttons should not be used as ONand OFFswitches.
3. The cord and plug are not intended to offer protection to externally connected loads or supply circuits.
4. The cord and plug are intended for indoor use only.
5
PRODUCT DIAGRAM
1. Air Outlet Grill
2. Control Panel
3. Casters
4. Air Intake Grill
5. Remote Control Sensor
6. Air Filter
7. Carry Handle
8. Air Exhaust Hose Discharge Opening
9. Condensation Drain Hole
10. Power Cord
11. Exhaust Hose
12. Window Kit Adapter
13. Exhaust Hose Connector
14. Remote Control
15. Caster Locks
16. Screws
17.Window Kit
18. Window Kit Adapter Extension
19. Drainage Hose
20. Rubber Plug
21. Product Manual (Not Shown)
6
Loading...
+ 12 hidden pages