INTRODUCTION
Thank you for purchasing the Soleus Air KY-32E 12000 BTU Portable Evaporative Air Conditioner. This unit is
designed to improve living and working comfort by providing cooling, dehumidifying and fan functions with
minimal installation.
This multi-functional portable air conditioner operates as an air conditioner, dehumidifier, and fan. Unlike
traditional portable air conditioners, there is no bucket to empty. The condensate water is evaporated and removed
through the exhaust duct along with warm exhaust air. At 12000 BTUs the KY-32E is one of the most powerful
portable air conditioners on the market. In addition, the high speed motor allows for operation in high temperatures
Soleus Air “Smart Chip” technology and precise control of the unit
When operating as an air conditioner, this unit is designed for spot cooling or cooling a room no larger than 450
square feet with a standard eight foot ceiling height. Please read these instructions carefully before operating this
appliance. When using this air conditioner, always exercise basic safety precautions.
This easy-to-use manual will guide you in obtaining the best use of your Portable Air Conditioner.
Please complete the following information for future reference. You will need it to obtain warranty service.
Model Number: KY-32E
Serial Number *: ___________________________________________________________________
Date of Purchase: ___________________________________________________________________
Place of Purchase: ___________________________________________________________________
*The Serial number is located on the back of the unit. Retain this Owner’s Manual with your sales receipt as a
permanent record of your purchase.
Customer Service:
1-888-876-5387
9451 Telstar Avenue
El Monte, California 91731
www.soleusair.com
3
IMPORTANT SAFEGUARDS
Before installing and using the portable air conditioner, please read this Owner’s manual carefully.
1. Never use or store gasoline or other flammable vapor or liquid near this unit.
2. Maintain at least 20” (50cm) clearance space around all side of the unit. Do not obstruct air inlet or outlet
grilles.
3. All in-home wiring must comply with local and national codes and be installed by a qualified technician.
All wiring problems should be resolved by a qualified technician BEFORE installation and use of this air
conditioner.
4. The power supply must be properly grounded.
5. For your safety, this unit is grounded through the power cord plug when connected to a matching wall
outlet. Do not use an adapter plug or extension cord.
6. When removing the power cord from the wall outlet, always grasp the plug firmly and pull straight from
the outlet. Never unplug the air conditioner by pulling on the cord itself.
7. Always inspect the power cord and plug for signs of damage before use.
8. Repair or replace immediately, all power cords that have become frayed or otherwise damaged. Do not use
a cord that shows cracks or abrasion damage along its length, the plug or the connector end.
9. Do not use the unit in the immediate surroundings of a bath, a shower or a swimming pool. Never immerse
the unit in water or any other liquid.
10. Keep out of reach of children.
11. Use product only as directed in this manual; unintended use may void the warranty.
NOTE: If for any reason this product requires service, we strongly recommend that a certified
technician perform the service.
4
LCDI POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as
required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no
termination on the load side and a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal
current leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will
remain de-energized until the devise has been manually reset. This is intended to reduce the risk of a fire in the
power cord or combustible materials nearby. The cord shields are not grounded and they must be considered a shock
hazards if exposed. The cord shield must not be connected to ground or to any exposed metal.
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:
1. Plug power cord into wall outlet
2. Press TEST Button, circuit should trip, cutting power to the air conditioner
3. Press RESET button for use
If a test is performed and the indicator light remains ON, current leakage has been detected. Do not use the air
conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Customer Service for troubleshooting
recommendations.
WARNING:
1. DO NOT press TEST button while the air conditioner is operating.
2. The TEST and RESET buttons should not be used as “ON” and “OFF” switches.
3. The cord and plug are not intended to offer protection to externally connected loads or supply circuits.
4. The cord and plug are intended for indoor use only.
5
PACKAGE CONTENTS
1. Portable Air Conditioner
2. Air Exhaust Duct
3. Exhaust Duct Window Kit Adapter
4. Remote Control
5. AAA Batteries (2)
6. Window Kit - 3 Sliding Panels
7. Window Kit Fastener Screws (4)
8. Continuous Drainage Tube
9. Exhaust Outlet Wall Cover
10. User’s Manual
PARTS DIAGRAM
FRONT VIEW
6
Loading...
+ 12 hidden pages
You need points to download manuals.