Soleus Air KFHHP-12-OD, KFHHP-12-ID, KFHHP-09-OD, KFIHP-09-ID User Manual

Wall Mounted Mini Split
Heat Pump
Air Conditioner
OPERATING AND INSTALLATION MANUAL Model: KFIHP-09-ID / KFHHP-09-OD KFHHP-12-ID / KFHHP-12-OD
Indoor Unit.
Outdoor Unit.
Thank you for selecting Soleus Air. To ensure proper
operation, please read this manual and keep it for
future reference.
TABLE OF CONTENTS
STRUCTURE AND OPERATION...……………………..……………………………………….....1-8
Name of Each Part
…………………………………………………………….………..………...……1 The Instructions before Use…………………………………………………………………………2-3 Specifications and Technical Data……………………………….……..……………….…………….4
Remote Control Operation………………………………………………….….…...............………5-6
How to Insert Batteries……………………………………………..………………….………...……7 Operation………………………………………………………………………………………...……8
INSTALLATION...……………………..……………………………………………………...........9-14
Installation Location………………………………………………….………………………………9
Electric Wiring………………………………………....………………………………...….……….10
Grounding Requirement…………………………………………………….…...……..………....….10
Installation Dimension Diagram……………………………………………………….…….………11
Installation…………………………………………………………………………….……….....12-13
Install the Indoor Unit…………………………………………………………………………….....14
Install the Outdoor Unit……………………………………………………………………...…..15-16 Test Operation and Check after Installation……………………………….………………………...17
CARE AND MAINTENANCE……………………………………………...………..…….……...…18
Care and Maintenance ………………………………………………………....………….…….18-19
Trouble Shooting………………………………….………………………………………..……20-21
ELECTRICAL SCHEMATIC DIAGRAM…………………………………...………..…………22-23
Electrical Schematic Diagram (Indoor Unit)…………………………...……………......………….22
Electrical Schematic Diagram (Outdoor Unit)………..……………………….……………………23
WARRANTY…………………………………………………………………………………………24
Danger Caution.
Thank you for selecting Soleus Air. To ensure proper operation, please read this manual and keep it for future reference.
This mark indicates a direction/procedure that must be followed!
Name of Each Part
Structure and Operation
- 1 -
The Instructions before Use
Warning
Grounding: The unit must be properly
grounded.
Don’t attempt to repair the air conditioner by
yourself. There are no user replaceable parts. Please contact your authorized dealer.
Never block the air inlet or outlet of indoor and
outdoor unit.
Disconnect the power when the unit is not being
used for extended periods of time.
If your air conditioner malfunctions,
discontinue use and call your authorized dealer.
Don’t step on the top of the outdoor unit or
place something on it.
Never store flammable liquids near your air
conditioner.
The condensing unit should be securely
mounted to avoid damage.
- 2 -
The Instructions before Use
Set the room temperature appropriately.
The difference between indoor and outdoor temperature shall be 40 °F.
Close all doors & windows for efficient
operation.
Adjust the air flow and direction properly.
When the air conditioner is running, you can press the SWING key on the remote control to adjust the guide louver and change the direction of air flow.
To avoid harm to your pets or plants, never
direct the airflow at them.
To avoid damage or electric shock, never spray
liquid onto the unit.
This air conditioner cannot be used for
drying clothes or refrigerating foods.
- 3 -
Specification and Technical Data
Model
Function Cool / Heat
Accessory Air Cleaner
Cooling capacity (Btu/h) 9000 12000
Heating capacity (Btu/h) 9500 13000
Power Supply (V) 115V~ 208~230
Frequency (Hz) 60
Cooling/Heating rated current(A) 12/13.6 9/10
Cooling/Heating rated power(W) 1250/1450 1700/1750
Cooling/Heating power input(W) 730/840 1100/1200
KFIHP-09-ID
KFIHP-09-OD
KFHHP-12-ID
KFHHP-12-OD
Recycling air Volume
m3/h
Refrigerant and weight(lbs)
R410A 2.6 lbs R410A 2.8 lbs
550
Water proof level IP24
Noise(Indoor/Outdoor)dB(A) 43/55
Climate type T1
Anti-electric shock protection I
Weight Indoor/Outdoor)(lbs) 24.3/99.2 24.3/99.2
Dimensions (W x D x H)
Outdoor unit
Indoor unit
30.31”×7.48”×9.84” 32.68”×8.86”×11.22”
33.39”×12.6”×21.26” 33.39”×12.6”×21.26”
Connection Pipe:
Length (ft) 19.68 Gas additional charge(oz/ft) 0.16
Outer Diameter
Max Distance
Liquid Pipe (mm) Gas Pipe (mm) Height (ft) 16.4 Length (ft) 49.21
Φ6(1/4”) Φ12(1/2”)
1. All above are tested and certified to ETL specification.
2. All above could be changed without notice; the latest specifications are on the nameplate of your air conditioner.
3. When the unit is restarted after it stopping, it can automatically resume the last running mode, and the outdoor unit
starts later.
Working temperature range:
Indoor side DB/WB(°F) Outdoor side DB/WB(°F)
Maximum cooling 89.6 / 73.4 109.4 / 78.8
Minimum cooling 69.8 / 59 69.8 / -
Maximum heating 80.6 / - 75.2 / 64.4
Minimum heating 68 / - 23 / 21.2
- 4 -
Remote Control Operation
Function-Remote control
Note:
Don't drop the remote control.
Don't place the remote control in a location exposed to direct sunlight.
When the unit is restarted after stopped, it will automatically resume its last running mode, and the
outdoor unit will start there after.
TEMP+ TEMP- Button:
Under the COOL, DRY, FAN or HEAT mode, press these two buttons could set the temperature, the temp. setting range is
60.8°F -86°F, the temp. can be memorized under each mode.
MODE Button:
When the unit is turned on, press this button. The AUTO, COOL, DRY, FAN or HEAT mode can then be selected.
FAN SPEED Button:
When the unit starts up, under the AUTO, COOL, FAN or HEAT mode, press this button and select Auto fan, Low fan, Middle fan, High fan. At DRY mode, the fan speed runs at Low fan speed. The FAN SPEED can be memorized under various modes.
SLEEP Button:
Under COOL, DRY & HEAT mode, press the button once to start the SLEEP function, when pressed again, it will stop.
CLOCK Button:
When pressing this button once, the icon of CLOCK will flash, and can be adjusted. At CLOCK adjustment, press the TIME+ once, the ones placed on the minute will be increased 1, and continuously press 1 sec above, the tens place on the minute will be increased 1 in every half second. When pressing the TIME-, the ones placed on the minute will be decreased 1, and continuously press 1 sec above, the tens place will be decreased 1 in every half second. After adjusting please press the CLOCK button again for confirming.
- 5 -
Remote Control Operation (Continued)
Liquid Crystal Display.
It shows all set contents.
ON/OFF Button
Press ON. Press OFF.
T-ON Button.
When pressing this button once, enter into T-ON setting, the icon of T-ON flash, every press of TIME+, the time of T-ON will be increased 1min. When continuously press 1 sec above, the tens placed on minute will be increased 1, every press of TIME- will be decreased 1 minute, when continuously press 1 sec above, the tens placed on minute will be decrease 1 in every half second, and it goes round with 12 hours.
TIME+ TIME- Button
Function instruction please refer to T-ON button, T­OFF button, CLOCK button.
SWING Button:
Press once to have louvers swing [oscillate]. Press twice in one second the panel light will turn on. Press twice again and the light will turn off.
T-OFF Button
Press this button once to enter into T-OFF setting, the icon of T­OFF will flash, the T­OFF button is available in ON or OFF mode, the setting method is the same with T-ON.
CANCEL Button
Pressing this button will cancel timer.